DOI QR코드

DOI QR Code

Withdrawal and Lateral Resistance of Nail Joints Composed of Dimension Lumber and OSB in Light-Frame Wood Construction

경골목구조에서 구조재와 오에스비로 구성된 못 접합부의 인발 및 전단성능

  • 오세창 (대구대학교 생명환경대학 산림자원학과)
  • Received : 2013.02.20
  • Accepted : 2013.05.10
  • Published : 2013.05.25

Abstract

The nailed joints in wood construction are commonly designed to resist and carry the lateral load but also subject to withdrawal force like uplift load due to the wind. This research was conducted to evaluate the performance of nailed joint composed of dimension lumber and sheathing materials through the nail withdrawal and unsymmetric double shear joint test, and then compared to current design values. The withdrawal strength was greatly dependant on wood specific gravity, and the withdrawal strength of I-joist with OSB showed higher value in spite of low specific gravity. The maximum withdrawal loads were greater than that of derived current design values about 5 times. The lateral resistance of Japanese larch/OSB nailed joints was higher than that of SPF/OSB nailed joint, and derived allowable lateral strength of nailed joints in this study exceeded the current design values. The failure mode of nailed joints was primarily due to the nail bending and this tendency was notable in SPF/OSB nailed joint.

경골목조건축에서 못 접합부는 수평하중을 지지하고 전달하도록 설계되지만, 바람으로 인한 상향력처럼 인발하중에 직면하기도 한다. 본 연구에서는 경골목조건축에서 일반적으로 사용되는 구조재와 덮개로 구성된 못 접합부에 대하여 인발성능과 2면 전단시험을 통해 인발 및 측방하중에 대한 내력성능을 시험하고 설계기준에 부합되는 가를 평가하였다. 인발하중에 대한 내력성능은 부재의 비중에 의해 크게 좌우되었으며 I형장선의 경우 낮은 밀도에도 불구하고 높은 인발성능을 나타내었다. 최대 인발하중은 기준허용 최대 인발하중보다 매우 높게 나타났다. 전단성능도 비중이 큰 낙엽송과 오에스비로 구성된 접합부가 비중이 작은 SPF와 오에스비로 구성된 접합부보다 높은 성능을 나타내었으며 모두 기준설계치보다 높은 성능을 나타내었다. 접합부의 변형은 주로 못의 휨 변형에 의한 것으로 나타났으며 SPF와 오에스비로 구성된 접합부에서의 못의 휨 변형이 현저하게 나타났다.

Keywords

References

  1. American Forest and Paper Association. 2005. National design specification for wood construction. ANSI/AF&PA NDS-2005.
  2. Celebi, G. and M. Kilic. 2007. Nail and screw withdrawal strength of laminated veneer lumber made up hardwood and softwood layers. Construction and Building Materials 21: 894-900. https://doi.org/10.1016/j.conbuildmat.2005.12.015
  3. Chow, P., J. D. Mcnatt, S. J. Lambrechts, and G. Z. Gertner. 1988. Direct withdrawal and head pullthrough performance of nails and staples in structural wood-based panel materials. Forest Prod. J. 38(6): 19-25.
  4. Forest Products Laboratory. 2010. Wood handbook-Wood as an engineering material. General Technical Report FPL-GTR-190. Madison, WI. U.S. Department of Agriculture, Forest Service, Forest Products Laboratory.
  5. Meekum U. and Y. Mingmongkol. 2011. Experimenatal design of laminated veneer lumber fiber reinforced composite: Processing parameters and its durability. 16th International Conference on Composite Structures. ICCS 16. FEUP, Porto, 2011.
  6. Sinha, Arijit and Rakesh Gupta. 2009. Strain distribution in OSB and GWB in wood-frame shear walls. Journal of Structural Engineering 135(6): 666-675. https://doi.org/10.1061/(ASCE)0733-9445(2009)135:6(666)
  7. Winistorfer S. and L. Soltis 1994. Lateral and withdrawal strength of nail connections for manufactured housing. Journal of Structural Engineering 120(12): 3577-3594. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:12(3577)
  8. 국토교통부. 2009. 건축구조기준 제8장 목구조.
  9. 서진석, 황성욱, 황권환, 정기영, 정하현. 2012. 오에스비 대체용 국내산 합판의 못 접합부 전단내력성능. 목재공학 40(4): 287-293.
  10. 오세창. 2000. 국산 $2{\times}4$ 구조재 못 결합부의 인발 및 전단성능. 한국목재공학회 2000 학술발표논문집: 13-18.
  11. 장상식. 1999. 목재-판재 못 접합부의 압축전단시험. 한국목재공학회 1999 추계학술발표논문집: 79-84.
  12. 한국표준협회. 2002. KS F 3020 침엽수 구조용재.
  13. 한국표준협회. 2004. KS F ISO 9087 목재의 못 또는 나사못 뽑기 저항시험방법.
  14. 한국표준협회. 2005. KS F 2153 목구조 철물접합부의 전단시험방법.
  15. 황권한, 박문재. 2008. 오에스비에 대한 각종 부재의 못전단성능. 목재공학 36(4): 66-76. https://doi.org/10.5658/WOOD.2008.36.4.066
  16. 日本木材學會.物理.工學編編輯委員會. 1985. 木材科學實驗書 -工學編. 日本木材學會創立30周年記念事業委員會.

Cited by

  1. Wood Plastic Composite Panels: Influence of the Species, Formulation Variables and Blending Process on the Density and Withdrawal Strength of Fasteners vol.22, pp.2, 2014, https://doi.org/10.1007/s10924-013-0634-7