DOI QR코드

DOI QR Code

Control Strategy for Three-Phase Grid-Connected Converters under Unbalanced and Distorted Grid Voltages Using Composite Observers

  • 투고 : 2012.11.27
  • 발행 : 2013.05.20

초록

This paper proposes a novel scheme for the current controller for the grid-side converter (GSC) of permanent-magnet synchronous generator (PMSG) wind turbines to eliminate the high-order harmonics in the grid currents under grid voltage disturbances. The voltage unbalance and harmonics in three-phase systems cause grid current distortions. In order to mitigate the input current distortions, multi-loop current controllers are applied, where the positive-sequence component is regulated by proportional-integral (PI) controllers, and the negative-sequence and high-order harmonic components are regulated by proportional-resonance (PR) controllers. For extracting the positive/negative-sequence and harmonic components of the grid voltages and currents without a phase delay or magnitude reduction, composite observers are applied, which give faster and more precise estimation results. In addition, an active damping method using PR controllers to damp the grid current component of the resonant frequency is employed to improve the operating stability of VSCs with inductor-capacitor-inductor (LCL) filters. The validity of the proposed method is verified by simulation and experimental results.

키워드

참고문헌

  1. K. Hatua, A. K. Jain, D. Banerjee, and V. T. Ranganathan, "Active damping of output LC filter resonance for vectorcontrolled VSI-fed AC motor drives," IEEE Trans. Ind. Electron., Vol. 59, No. 1, pp. 334-342, Jan. 2012. https://doi.org/10.1109/TIE.2011.2141093
  2. D.-E. Kim and D.-C. Lee, "Feedback linearization control of three-phase UPS inverter systems," IEEE Trans. Ind. Electron., Vol. 57, No. 3, pp. 963-968, Mar. 2010.
  3. M. Liserre, R. Teodorescu, and F. Blaabjerg, "Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values," IEEE Trans. Power. Electron., Vol. 21, No. 1, pp. 263-272, Jan. 2006. https://doi.org/10.1109/TPEL.2005.861185
  4. X. Zhang, W. Pan, Y. Liu, and D. Xu, "Improved grid voltage control strategy for wind farm with DFIG connected to distribution networks," Journal of Power Electronics, Vol. 12, No. 3, pp. 495-502, May 2012. https://doi.org/10.6113/JPE.2012.12.3.495
  5. H.-S. Song and K. Nam, "Dual current control scheme for PWM converter under unbalanced input voltage conditions," IEEE Trans. Ind. Electron., Vol. 46, No. 5, pp. 953-959, Oct. 1999. https://doi.org/10.1109/41.793344
  6. J. Dannehl, C. Wessels, and F. Wilhelm, "Limitations of voltage-oriented PI current control of grid-connected PWM rectifiers with LCL filters," IEEE Trans. Ind. Electron., Vol. 56, No. 2, pp. 380-388, Feb. 2009. https://doi.org/10.1109/TIE.2008.2008774
  7. J. Dannehl, M. Liserre, and F. Wilhelm, "Filter-based active damping of voltage source converters with LCL filters," IEEE Trans. Ind. Electron., Vol. 58, No. 8, pp. 3623-3632, Aug. 2011. https://doi.org/10.1109/TIE.2010.2081952
  8. X. Wang, X. Ruan, S. Liu, and C. K. Tse, "Full feedforward of grid voltage for grid-connected inverter with LCL filter to suppress current distortion due to grid voltage harmonics," IEEE Trans. Power. Electron., Vol. 25, No. 12, pp. 3119-3127, Dec. 2010. https://doi.org/10.1109/TPEL.2010.2077312
  9. Y. A. R. I. Mohamed, "Mitigation of dynamic, unbalanced, and harmonic voltage disturbances using grid-connected inverters with LCL filter," IEEE Trans. Ind. Electron., Vol. 58, No. 9, pp. 3914-3924, Sep. 2011. https://doi.org/10.1109/TIE.2010.2098372
  10. E. Twining and D. G. Homles, "Grid current regulation of a three-phase voltage source inverter with an LCL input filter," IEEE Trans. Power. Electron., Vol. 18, No. 3, pp. 888-895, May. 2003. https://doi.org/10.1109/TPEL.2003.810838
  11. F. Liu, Y. Zhou, S. Duan, J. Yin, and F. Liu, "Parameter design of a two-current-loop controller used in a gridconnected inverter system with LCL filter," IEEE Trans. Ind. Electron., Vol. 56, No. 11, pp. 4483-4491, Nov. 2009. https://doi.org/10.1109/TIE.2009.2021175
  12. K. Lee, T. M. Jahns, T. A. Lipo, V. Blasko, and R. D. Lorenz, "Observer-based control methods for combined source-voltage harmonics and unbalance disturbances in PWM voltage-source converters," IEEE Trans. Ind. Appl., Vol. 45, No. 6, pp. 2010-2021, Nov./Dec. 2009. https://doi.org/10.1109/TIA.2009.2031854
  13. T. H. Nguyen and D.-C. Lee, "Control of three-phase grid converters based on composite observer for unbalanced and distorted grid voltage," in Proc. IEEE ISIE, May. 2012, pp. 1874-1879.
  14. S. Alepuz, S. B. Monge, J. Bordonau, J. A. M. Velasco, C. A. Silva, J. Pontt, and J. Rodriquez, "Control strategies based on symmetrical components for grid-connected converters under voltage dips," IEEE Trans. Ind. Electron., Vol. 56, No. 6, pp. 2162-2173, Jun. 2009. https://doi.org/10.1109/TIE.2009.2017102
  15. R. Data and V. T. Ranganathan, "A method of tracking the peak power points for a variable speed wind energy conversion system," IEEE Trans. Energy Convers., Vol. 18, No. 1, pp. 163-168, Mar. 2003. https://doi.org/10.1109/TEC.2002.808346
  16. K. Selvajyothi and P. A. Janakiraman, "Reduction of voltage harmonics in single phase inverters using composite observers," IEEE Trans. Power Del., Vol. 25, No. 2, pp. 1045-1057, Apr. 2010. https://doi.org/10.1109/TPWRD.2009.2035917
  17. K. Selvajyothi and P. A. Janakiraman, "Extraction of harmonics using composite observers," IEEE Trans. Power Del., Vol. 23, No. 1, pp. 31-40, Jan. 2008. https://doi.org/10.1109/TPWRD.2007.911141
  18. T. H. Nguyen, D.-C. Lee, and S.-G. Lee, "Sinusoidal current control of single-phase PWM converters under voltage source distortion using composite observer," Trans. of KIPE, Vol. 16, No. 5, pp. 466-476, Oct. 2011. https://doi.org/10.6113/TKPE.2011.16.5.466
  19. S.-K. Sul, Control of electric machine drive systems, Wiley, 2011.
  20. A. O. Ibrahim, T. H. Nguyen, D.-C. Lee, and S.-C. Kim, "A fault ride-through technique of DFIG wind turbine systems using dynamic voltage restorers," IEEE Trans. Energy Convers., Vol. 26, No. 3, pp. 871-882, Sep. 2011. https://doi.org/10.1109/TEC.2011.2158102
  21. P. Rodriguez, J. Pou, J. Bergas, J. I. Candela, R. P. Burgos, and D. Boroyevich, "Decoupled double synchronous reference frame PLL for power converters control," IEEE Trans. Power Electron., Vol. 22, No. 2, pp. 584-592, Mar. 2007 https://doi.org/10.1109/TPEL.2006.890000

피인용 문헌

  1. Pattern Recognition of Monitored Waveforms from Power Supplies Feeding High-Speed Rail Systems vol.11, pp.1, 2016, https://doi.org/10.5370/JEET.2016.11.1.055
  2. A Series-Connected Topology of a Diode Rectifier and a Voltage-Source Converter for an HVDC Transmission System vol.29, pp.4, 2014, https://doi.org/10.1109/TPEL.2013.2283368
  3. IDA-PBC controller design for grid connected Front End Converters under non-ideal grid conditions vol.142, 2017, https://doi.org/10.1016/j.epsr.2016.08.041
  4. DC-Link Capacitance Minimization in T-Type Three-Level AC/DC/AC PWM Converters vol.62, pp.3, 2015, https://doi.org/10.1109/TIE.2014.2345354
  5. Grid integration improvement for single-phase inverters of small wind turbines under distorted voltage conditions vol.87, 2017, https://doi.org/10.1016/j.ijepes.2016.11.003
  6. Fault Tolerant Control of DC-Link Voltage Sensor for Three-Phase AC/DC/AC PWM Converters vol.14, pp.4, 2014, https://doi.org/10.6113/JPE.2014.14.4.695
  7. Grid-connected Control Strategies for a Dual Power Flow Wind Energy Conversion System vol.45, pp.18, 2017, https://doi.org/10.1080/15325008.2017.1401181