• Title/Summary/Keyword: Grid converter

Search Result 490, Processing Time 0.029 seconds

Stability Enhancement of a Hybrid Micro-grid System in Grid Fault Condition

  • Ambia, Mir Nahidul;Al-Durra, Ahmed;Caruana, Cedric;Muyeen, S.M.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.225-231
    • /
    • 2013
  • Low voltage ride through capability augmentation of a hybrid micro-grid system is presented in this paper which reflects enhanced reliability in the system. The control scheme involves parallel connected multiple ac-dc bidirectional converters. When the micro-grid system is subjected to a severe voltage dip by any transient fault single power converter may not be able to provide necessary reactive power to overcome the severe voltage dip. This paper discusses the control strategy of additional power converter connected in parallel with main converter to support extra reactive power to withstand the severe voltage dip. During transient fault, when the terminal voltage crosses 90% of its pre-fault value, additional converter comes into operation. With the help of additional power converter, the micro-grid system withstands the severe voltage fulfilling the grid code requirements. This multiple converter scheme provides the micro-grid system the capability of low voltage ride through which makes the system more reliable and stable.

Analysis and Control of Neutral Point Current Deviation in Grid Tied 3-Level NPC Converter under Various Grid Unbalanced Conditions (다양한 불평형 계통 상황에서 계통 연계형 3-레벨 NPC 컨버터의 중성점 전류 변동에 대한 해석 및 제어)

  • Choi, Jaehoon;Suh, Yongsug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.385-393
    • /
    • 2020
  • This study introduces an analysis and control method for the variation of neutral point current in a grid-tied three-level neutral point clamped (NPC) converter under various grid imbalance operating conditions. Various fault cases with unbalanced amplitude and phase are systematically categorized and described using a unified metric called the imbalance factor. The fundamental component of neutral point current is generated under grid imbalance cases. The pattern and behavior of this fundamental component of neutral point current highly depend on the imbalance factor regardless of the particular type of grid fault cases. The control scheme for regulating the negative sequential component of AC input current effectively reduces the size of the fundamental component of neutral point current under a wide range of grid imbalance cases. The control scheme will enable a grid-tied three-level NPC converter to operate reliably and stably under various types of grid faults.

One-Cycle Control Strategy for Dual-Converter Three-Phase PWM Rectifier under Unbalanced Grid Voltage Conditions

  • Xu, You;Zhang, Qingjie;Deng, Kai
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.268-277
    • /
    • 2015
  • In this paper, a dual-converter three-phase pulse width modulation (PWM) rectifier based on unbalanced one-cycle control (OCC) strategy is proposed. The proposed rectifier is used to eliminate the second harmonic waves of DC voltage and distortion of line currents under unbalanced input grid voltage conditions. The dual-converter PWM rectifier employs two converters, which are called positive-sequence converter and negative-sequence converter. The unbalanced OCC system compensates feedback currents of positive-sequence converter via grid negative-sequence voltages, as well as compensates feedback currents of negative-sequence converter via grid positive-sequence voltages. The AC currents of positive- and negative-sequence converter are controlled to be symmetrical. Thus, the workload of every switching device of converter is balanced. Only one conventional PI controller is adopted to achieve invariant power control. Then, the parameter tuning is simplified, and the extraction for positive- and negative-sequence currents is not needed anymore. The effectiveness and the viability of the control strategy are demonstrated through detailed experimental verification.

Grid-tied Power Converter for Battery Energy Storage Composed of 2-stage DC-DC Converter

  • Kim, Do-Hyun;Lee, Yoon-Seok;Han, Byung-Moon;Kim, Ju-Yong;Chae, Woo-Kyu
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1400-1408
    • /
    • 2013
  • This paper proposes a new grid-tied power converter for battery energy storage, which is composed of a 2-stage DC-DC converter and a PWM inverter. The 2-stage DC-DC converter is composed of an LLC resonant converter connected in cascade with a 2-quadrant hybrid-switching chopper. The LLC resonant converter operates in constant duty ratio, while the 2-quadrant hybrid-switching chopper operates in variable duty ratio for voltage regulation. The operation of proposed system was verified through computer simulations. Based on computer simulations, a hardware prototype was built and tested to confirm the technical feasibility of proposed system. The proposed system could have relatively higher efficiency and smaller size than the existing system.

A Noval High Efficiency Grid Connected 1kW PCS for Fuel Cell (새로운 고효율 계통연계 1kW 연료전지용 PCS)

  • Kim, Tae-Jin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.5
    • /
    • pp.417-422
    • /
    • 2008
  • In this paper, a novel DC/DC low-voltage high-current converter circuit is proposed to improve the efficiency of power converter used in the grid-connected fuel-cell generator system. We proposed a novel high efficiency grid-connected power conditioning system for RPG fuel cell. On the result of that, the loss of system was decreased rapidly by driving stack within the condition of maximum efficiency. The peak currents of the current-type inductor and the transformer's coil are reduced by synchronizing switching frequency of Buck-type converter is increased twice as the Push-Pull converter's switching frequency. The novel structure of DC/DC converter is able to realize ZVS-ZCS in fuel-cell system is proposed. The proposed switching component of Push-Pull converter has the ZVS and ZCS function by using the circuit of new passive clamp.

Predictive control and modeling of a point absorber wave energy harvesting connected to the grid using a LPMSG-based power converter

  • Abderrahmane Berkani;Mofareh Hassan Ghazwani;Karim Negadi;Lazreg Hadji;Ali Alnujaie;Hassan Ali Ghazwani
    • Ocean Systems Engineering
    • /
    • v.14 no.1
    • /
    • pp.17-52
    • /
    • 2024
  • In this paper, the authors explore the modeling and control of a point absorber wave energy converter, which is connected to the electric grid via a power converter that is based on a linear permanent magnet synchronous generator (LPMSG). The device utilizes a buoyant mechanism to convert the energy of ocean waves into electrical power, and the LPMSG-based power converter is utilized to change the variable frequency and voltage output from the wave energy converter to a fixed frequency and voltage suitable for the electric grid. The article concentrates on the creation of a predictive control system that regulates the speed, voltage, and current of the LPMSG, and the modeling of the system to simulate its behavior and optimize its design. The predictive model control is created to guarantee maximum energy output and stable grid connection, using Matlab Simulink to validate the proposed strategy, including control side generator and predictive current grid-side converter loops.

BPF-based Grid Voltage Feedforward Control of Grid-connected Converters for Improving Robust Stability

  • Yang, Shude;Tong, Xiangqian;Yin, Jun;Wang, Haiyan;Deng, Yaping;Liu, Le
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.432-441
    • /
    • 2017
  • Grid voltage feedforward is extensively used for controlling grid-connected converters. However, the conventional voltage feedforward control reduces the stability margins of the converter connected to a high-impedance grid. The effect mechanism of voltage feedforward on the grid-connected converter control under high-inductive conditions of the grid impedance is clearly explained in this study using the equivalent transformations of control block diagrams. Results show that the delay produced by the digital control is the root cause of this effect. An improved voltage feedforward strategy, in which a bandpass filter (BPF) is introduced into the feedforward path, is proposed to strengthen the converter's robust stability against grid impedance variations. The selection method of the BPF's bandwidth is also provided considering the tradeoff between the response speed to the grid voltage sag and the system's robust stability. The converter can work stably over a wide range of the grid impedance through the proposed approach. Simulation and experimental results fully verify the effectiveness of the BPF-based voltage feedforward strategy.

Voltage Feedforward Control with Time-Delay Compensation for Grid-Connected Converters

  • Yang, Shude;Tong, Xiangqian
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1833-1842
    • /
    • 2016
  • In grid-connected converter control, grid voltage feedforward is usually introduced to suppress the influence of grid voltage distortion on the converter's grid-side AC current. However, owing to the time-delay in control systems, the suppression effect of the grid voltage distortion is seriously affected. In this paper, the positive effects of the grid voltage feedforward control are analyzed in detail, and the time-delay caused by the low-pass filter (LPF) in the voltage filtering circuits and digital control are summarized. In order to reduce the time-delay effect on the performance of the feedforward control, a voltage feedforward control strategy with time-delay compensation is proposed, in which, a leading correction of the feedforward voltage is used. The optimal leading step used in this strategy is derived from analyzing the phase-frequency characteristics of a LPF and the implementation of digital control. By using the optimal leading step, the delay in the feedforward path can be further counteracted so that the performance of the feedforward control in terms of suppressing the influence of grid voltage distortion on the converter output current can be improved. The validity of the proposed method is verified through simulation and experiment results.

DC Fault Study in Point-to-Point HVDC Grid based on MMC VSC (MMC VSC 기반 Point-to-Point HVDC Grid에서의 DC 고장 분석)

  • Lee, Dong-Su;Kim, Ki-Suk;Jang, Gil-soo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.161-162
    • /
    • 2015
  • 최근 세계적으로 전력계통의 대륙 간 연계나 신재생에너지, 분산전원의 계통 연계를 위해 HVDC(High voltage Direct Current)에 대한 연구가 활발히 진행되고 있다. 대용량, 장거리 송전이 필요한 경우 HVAC에서의 전력손실과 송전거리의 한계를 극복하기 위하여 HVDC가 새로운 대안으로 떠오르고 있으며, LCC(Line commutated Converter)와 VSC(Voltage Source Converter)의 기술발전이 비약적으로 이뤄지고 있다. 특히, DC Grid화를 위해서 유럽에서는 해상풍력을 연계한 Windfarm을 DC Grid화 하는 프로젝트가 활발히 진행되고 있다. 이러한 신재생 에너지의 계통 연계를 위해서 DC Grid가 본격적으로 논의가 되고 있고 관련분야에서는 기술개발을 앞다퉈 진행하고 있는 상황이다. DC Grid 구현을 위해 VSC HVDC가 최근 주목받고 있으며, VSC로 연계된 DC Grid의 AC 계통과의 연계를 위해 가장 필요한 것이 바로 DC 차단기라고 할 수 있겠다. 본 논문에서는 DC Grid의 고장분석을 위한 기초연구로써 MMC(Modular Multilevel Converter) VSC를 기반으로 한 Point-to-Point HVDC Grid에서의 DC 고장에 대한 분석을 실시하였으며 그 특징을 분석하였다.

  • PDF

High-Efficiency Power Conditioning System for Grid-Connected Photovoltaic Modules

  • Choi, Woo-Young;Choi, Jae-Yeon
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.561-567
    • /
    • 2011
  • This paper presents a high-efficiency power conditioning system (PCS) for grid-connected photovoltaic (PV) modules. The proposed PCS consists of a step-up DC-DC converter and a single-phase DC-AC inverter for the grid-connected PV modules. A soft-switching step-up DC-DC converter is proposed to generate a high DC-link voltage from the low PV module voltage with a high-efficiency. A DC-link voltage controller is presented for constant DC-link voltage regulation. A half-bridge inverter is used for the single-phase DC-AC inverter for grid connection. A grid current controller is suggested to supply PV electrical power to the power grid with a unity power factor. Experimental results are obtained from a 180 W grid-connected PV module system using the proposed PCS. The proposed PCS achieves a high power efficiency of 93.0 % with an unity power factor for a 60 Hz / 120 Vrms AC power grid.