DOI QR코드

DOI QR Code

Evaluation of Human Factors for the Next-Generation Displays: A Review of Subjective and Objective Measurement Methods

  • Mun, Sungchul (Department of Human Computer Interaction and Robotics, University of Science and Technology) ;
  • Park, Min-Chul (Department of Human Computer Interaction and Robotics, University of Science and Technology)
  • Received : 2012.11.12
  • Accepted : 2013.03.06
  • Published : 2013.04.30

Abstract

Objective: This study aimed to investigate important human factors that should be considered when developing ultra-high definition TVs by reviewing measurement methods and main characteristics of ultra-high definition displays. Background: Although much attention has been paid to high-definition displays, there have been few studies for systematically evaluating human factors. Method: In order to determine human factors to be considered in developing human-friendly displays, we reviewed subjective and objective measurement methods to figure out the current limitations and establish a guideline for developing human-centered ultra-high definition TVs. In doing so, pros and cons of both subjective and objective measurement methods for assessing humans factors were discussed and specific aspects of ultra-high definition displays were also investigated in the literature. Results: Hazardous effects such as visually-induced motion sickness, visual fatigue, and mental fatigue in the brain caused by undesirable TV viewing are induced by not only temporal decay of visual function but also cognitive load in processing sophisticated external information. There has been a growing evidence that individual differences in visual and cognitive ability to process external information can make contrary responses after exposing to the same viewing situation. A wide vision, ultra-high definition TVs provide, can has positive and negative influences on viewers depending on their individual characteristics. Conclusion: Integrated measurement methods capable of considering individual differences in human visual system are required to clearly determine potential effects of super-high vision displays with a wide view on humans. All of brainwaves, autonomic responses, eye functions, and psychological responses should be simultaneously examined and correlated. Application: The results obtained in this review are expected to be a guideline for determining optimized viewing factors of ultra-high definition displays and accelerating successful penetration of the next-generation displays into our daily life.

Keywords

References

  1. Abe, M., Yoshizawa, M., Sugita, N., Tanaka, A., Chiba, S., Yambe, T. and Nitta, S., A Method for Evaluating Effects of Visually-Induced Motion Sickness Using ICA for Photoplethysmography, Proceedings of the 30th International IEEE EMBS Conference, (pp. 4591-4954), Vancouver, BC. 2008.
  2. Ahn, C., Technology Development Trends of Ultra High Definition TV, Korea Society Broadcast Engineers Magazine, 13(1), 97-112, 2008.
  3. Csikszentmihalyi, M., Play and Intrinsic Rewards, Journal of Humanistic Psychology, 15(3), 41-63, 1975. https://doi.org/10.1177/002216787501500306
  4. Emoto, M., Nojiri, Y. and Okana, F., Changes in Fusional Vergence Limit and Its Hysteresis After Viewing Stereoscopic TV, Displays, 25(2-3), 67-76, 2004. https://doi.org/10.1016/j.displa.2004.07.001
  5. Hagura, H., Nakajima, M., Owaki, T. and Takeda, T., Study of Asthenopia Caused by the Viewing of Stereoscopic Images: Measurement by MEG and Other Devices, Proceedings of SPIE Conference on Human Vision and Electronic Imaging XI, 6057 (pp. 192-202), San Jose, CA. 2006.
  6. Halpern, S.D., Andrews, T.J. and Purves, D., Interindividual Variation in Human Visual Performance, Journal of Cognitive Neuroscience, 11(5), 521-534, 1999. https://doi.org/10.1162/089892999563580
  7. ITU-R BT.500, Methodology for the Subjective Assessment of the Quality of TV Pictures.
  8. Kim, Y.K., The Effects of Color Temperature on Video in Broadcasting Lighting, Journal of Broadcast Engineering, 16(1), 73-84, 2011. https://doi.org/10.5909/JEB.2011.16.1.073
  9. Lambooij, M., Ijsselsteijn, W.A., Fortuin, M.F. and Heynderickx, I., Visual Discomfort and Visual Fatigue of Steroscopic Displays: A Review, Journal of Imaging Science and Technology, 53(3), 030201: 1-14, 2009.
  10. Lambooij, M., Fortuin, M.F., IJsselsteijn, W.A. and Heynderickx, I., Reading Performance as Screening Tool for Visual Complaints from Stereoscopic Content, Displays, 33(2), 84-90, 2012. https://doi.org/10.1016/j.displa.2012.03.002
  11. Lee, C. and Choi, J., Strategy for providing QoS in IPTV Network, TTA Journal, 107, 41-45, 2006.
  12. Lee, E.C., Park, K.R., Whang, M. and Min, K., Measuring the Degree of Eyestrain Caused by Watching LCD and PDP Devices, International Journal of Industrial Ergonomics, 39(5), 798-806, 2009. https://doi.org/10.1016/j.ergon.2009.02.008
  13. Lee, E.C., Heo, H. and Park, K.R., The Comparative Measurements of Eyestrain Caused by 2D and 3D Displays, IEEE Transactions on Consumer Electronics, 56(3), 1677-1683, 2010. https://doi.org/10.1109/TCE.2010.5606312
  14. Lee, J.-H. and Song, J.-K., Individual Variation in 3D Visual Fatigue Caused by Stereoscopic Images, IEEE Transactions on Consumer Electronics, 58(2), 500-504, 2012. https://doi.org/10.1109/TCE.2012.6227453
  15. Li, H.-C.O., Seo, J., Kham, K. and Lee, S., Measurement of 3D Visual Fatigue Using Event-Related Potential (ERP): 3D Oddball Paradigm, Proceedings of 3DTV Conference, (pp. 213-216), Istanbul, 2008.
  16. Li, H-C.O., Human Factor Research on the Measurement of Subjective Three Dimensional Fatigue, Journal of Broadcast Engineering, 15(5), 607-616, 2010. https://doi.org/10.5909/JBE.2010.15.5.607
  17. Mun, S., Park, M.-C., Park, S. and Whang, M., SSVEP and ERP Measurement of Cognitive Fatigue Caused by Stereoscopic 3D, Neuroscience Letters, 525(2), 89-94, 2012a. https://doi.org/10.1016/j.neulet.2012.07.049
  18. Mun, S., Park, M.-C. and Yano, S., Human Factors of Super Hi-vision TV, Korea Society Broadcast Engineers Magazine, 17(4), 92-101, 2012b.
  19. Murata, A., Uetake, A. and Takasawa, Y., Evaluation of Mental Fatigue Using Feature Parameter Extracted From Event-related Potential, International Journal of Industrial Ergonomics, 35(8), 761-770, 2005. https://doi.org/10.1016/j.ergon.2004.12.003
  20. Nakasu, E., Super Hi-Vision on the Horizon: A Future TV System That Conveys an Enhanced Sense of Reality and Presence, IEEE Consumer Electronics Magazine, 1(2), 36-42, 2012
  21. Nishida, Y., Masaoka, K., Sugawara, M., Ohmura, K., Emoto, M. and Nakasu, E., Super Hi-vision System Offering Enhanced Sense of Presence and New Visual Experience, IET Journals, 3, 5-10, 2011.
  22. Park, I., Ha, K., Kim, M., Cho, S. and Choi, J.S., Analysis on Subjective Image Quality Assessments for 4K-UHD Video Viewing Environments, Journal of Broadcast Engineering, 15(4), 563-581, 2010. https://doi.org/10.5909/JBE.2010.15.4.563
  23. Park, S., Whang, M., Kim, J., Mun, S. and Ahn, S., Autonomic Nervous System Response Affected by 3D Visual Fatigue Evoked During Watching 3D TV, Korean Journal of The Science of Emotion & Sensibility, 14(4), 653-662, 2011.
  24. Sugawara, M., Masaoka, K., Emoto, M., Matsuo, Y. and Nojiri, Y., Research on Human Factors in Ultra-high-definition Television to Determine Its Specifications, SMPTE Motion Imaging Journal, 117(3), 23-29, 2008.
  25. Yang, S., Schlieski, T., Selmins, B., Cooper, S.C., Doherty, R.A., Corriveau, P.J. and Sheedy, J.E., Stereoscopic Viewing and Reported Perceived Immersion and Symptoms, Optometry and Vision Science, 89(7), 1068-1080, 2012. https://doi.org/10.1097/OPX.0b013e31825da430
  26. Yano, S., Ide, S., Mitsuhashi, T. and Thwaites, H., A Study of Visual Fatigue and Visual Comfort for 3D HDTV/HDTV Images, Displays, 23(4), 191-201, 2002. https://doi.org/10.1016/S0141-9382(02)00038-0

Cited by

  1. Overview of Measurement Methods for Factors Affecting the Human Visual System in 3D Displays vol.11, pp.11, 2015, https://doi.org/10.1109/JDT.2015.2389212