Abstract
In order to know the shear performances of a bolted connection in reinforced glulam depending upon the combination of textile glass fiber, a tensile-type shear test was conducted. Textile glass fiber was used as a reinforcement, whose glass fiber arrangement was a plain weaving type or a diagonal cloth type. Reinforced glulam was made up of 5 plies and it was produced by inserting and laminating the plies between laminas depending upon a changed insert position and combination form of textile glass fiber. Tensile-type shear test specimens were a steel plate insert-type and joined at end-distance 7D with bolts whose diameter 12 or 16 mm. In textile glass fiber reinforced glulam, whose volume ratio was 1%, the yield shear strength of a 12 mm bolted connection increased by 10% when a test specimen had reinforced internal layers than when external layers were reinforced. As for textile glass fiber reinforced glulam, whose volume ratio was 2%, the yield shear strength of a 12 mm bolted connection increased significantly by about 22% compared to the bolted connection of non-reinforced glulam, and the yield shear strength of a 16 mm bolted connection was improved by about 20% compared to the bolted connection of non-reinforced glulam.
직물형 유리섬유 조합에 따른 보강 집성재의 볼트 접합부 전단 성능을 알아보기 위하여 인장형 전단시험을 실시하였다. 보강재는 직물형 유리섬유로서 유리섬유 배열 형태는 평직형과 능직형을 사용하였다. 보강 집성재는 5층으로 직물형 유리섬유의 삽입 위치와 조합 형태를 달리하여 층재 사이에 삽입 적층시켜 제작하였다. 인장형 전단 시험편은 강판 삽입형로서 끝면거리 7D에 직경 12, 16 mm의 볼트로 접합하였다. 체적비 1% 직물형 유리섬유 보강 집성재의 경우 12 mm 볼트 접합부의 항복 전단내력은 집성재 외층부보다 내층부를 보강한 시험편에서 10% 큰 값을 나타내었다. 체적비 2% 직물형 유리섬유 보강 집성재의 항복 전단내력은 12 mm 볼트 접합부의 경우 각층재 사이에 삽입 적층시킨 시험편이 보강하지 않은 접합부보다 약 22% 향상되었으며, 16 mm 볼트 접합부의 항복 전단내력은 약 20% 향상되었다.