DOI QR코드

DOI QR Code

Performance Evaluation of Adhesively Fixed External Insulation and Finish System Using Vacuum Insulation Panels for Apartment Buildings

공동주택 습식 진공 외단열시스템 성능 평가

  • Park, Si Hyun (Dept. of Architectural Engineering, Ewha Womans Univ.) ;
  • Lim, Jae Han (Dept. of Architectural Engineering, Ewha Womans Univ.) ;
  • Song, Seung Yeong (Dept. of Architectural Engineering, Ewha Womans Univ.)
  • Received : 2013.10.07
  • Accepted : 2013.12.16
  • Published : 2013.12.31

Abstract

For the target goal of Zero-energy House construction in 2025, the government announced that the insulation regulations will be continuously enhanced. It has been predicted that high-performance insulation materials, such as vacuum insulation panel (VIP), should be used to decrease the thickness of outer walls. The aim of this study was to evaluate the performance of adhesively fixed external insulation and finish system (EIFS) with VIP. The energy performance of a base model with conventional internal insulation system and three alternatives of EIFS with VIP were analyzed by three-dimensional heat transfer simulation. Construction cost and convenience of each alternative were also evaluated and compared. As results, effective alternatives in terms of each performance as well as overall performance considering the weighting factors of each performance were suggested.

Keywords

References

  1. Activation plan for green city and building, The 6th conference of green growth committee, Ministry of Construction and Transport, 2009.
  2. Armin Binz et al, Vacuum insulation in the building sector: Systems and applications, IEA/ECBCS Annex 39 High performance thermal insulation systems(HiPTI), 2005.
  3. Par Johansson, Retrofitting of old exterior wall with vacuum insulation panels, Chalmers Univeristy of Technology, 2012.
  4. Markus Erb and Will Symons edited, Vacuum insulation panel properties and building applications, ECBCS Annex 39 Project summary report, 2010.
  5. Design criteria for building energy conservation, Ministry of Construction and Transport, Announcement 2012-69, 2012.
  6. Manual of design criteria for building energy conservation, Korea Energy Management Corporation, 2011.
  7. S. Y. Song, B. K. Koo, B. H. Chio, Insulation performances of the typical floor's front wall-slab and side wall-slab joints of apartment buildings with internal and external insulation systems, Journal of Architectural Institute of Korea, 24(8), 2008, pp.277-284.

Cited by

  1. Effectiveness of the Thermal Performance Improvement for Concurrent EIFS through Multi-dimensional Heat Transfer Analysis vol.32, pp.9, 2016, https://doi.org/10.5659/JAIK_PD.2016.32.9.121
  2. Simulation Performance of Building Wall with Vacuum Insulation Panel vol.180, 2017, https://doi.org/10.1016/j.proeng.2017.04.286