Abstract
Nowadays, precise prediction of the pump performance becomes more important than ever before in high-value industries such as power plants and large ships. The power consumed in such pumps of large head and capacity definitely affects the efficiency of the entire system. In this study, we report the theoretical and CFD results used in prediction of the performance change caused by the reduction of impeller diameter. We have found that the theoretical calculation is somehow useful at least in estimating the very beginning condition for the CFD main calculation.