Temperature and Power Generation Characteristics of c-Si G/G Spandrel Window depending on Opening Ratio of PV Module

스팬드럴용 투광형 결정계 PV창호의 셀 간격 개구율에 따른 온도 및 발전성능 해석연구

  • Yoon, Jong-Ho (Dept. of Architectural Engineering, Hanbat National University) ;
  • Kim, Dong-Su (Dept. of Architectural Engineering, Hanbat National University) ;
  • Oh, Myung-Hwan (Dept. of Architectural Engineering, Hanbat National University) ;
  • Lee, Jae-Beom (Dept of Climatic Change, National Institute of Environmental Research)
  • 윤종호 (한밭대학교 건축공학과) ;
  • 김동수 (한밭대학교 건축공학과) ;
  • 오명환 (한밭대학교 건축공학과) ;
  • 이재범 (국립환경과학원 기후변화연구과)
  • Received : 2012.08.17
  • Accepted : 20120000
  • Published : 2012.08.30

Abstract

This study aims to analyze characteristics of Cell surface temperature and generated power performance for improving PV(Photovoltaic) system condition according to the cell opening ratio of transparent crystal PV system at Spandrel of curtain-wall. For this purpose, alternatives were classified for eight different cases that opening ratio of transparent crystal PV system varied from 0% to 70%, which was used by simulation tool, EnergyPlus. As results, it turned out that increasing opening ratio of transparent crystal PV system led higher PV surface temperature, back-sheet type was thus the most advantageous for decreasing surface temperature, annual generating efficiency, and annual accumulated generating power. Consequently, blocking off air space from outside insolation can advantageously keep to be better condition for generated power performance.

Keywords

References

  1. http://en.wikipedia.org/wiki/spandrel
  2. Yoon, Jong-ho. Kim, Jae-ung., Experimental Study on the Thermal Effect of BIPV Modules Depending on the Ventilation Type of PV Module Backside, Journal of the Korean Solar Energy Society, Vol.26 No.1, 2006
  3. Yoon, Jong-ho., Experimental Study on the Combined Effect Power and Heat in 3kW Roof Integrated PV Module System, Journal of the Korean Solar Energy Society, 2007.3
  4. Yoon, Jong-ho. Oh, Myung-Hwan., A Study on the Glazing Surface Temperature and Thermal Shock of BIPV Window Applied to the SpandrelArea of Curtain Wall System in Office Building, Journal Architectural Institute of Korea, 2012
  5. Pack, Kyung-Eun., Generation Characteristics of BIPV Module as Spandrel Glass accoding to Temperature Variation, Korean Institute of Architectural Sustaninable Environment and Building Systems, 2007
  6. Pack, Kyung-Eun. Kang, Gi-Hwan., Experimental Verification of Prediction Equatin for Crystalline PV Modules Electrical Performance Considered Temperature Variation, Journal of the Korean Solar Energy Society, 2010
  7. Sin, Chi-Ung., SI Unit Air conditioning equipment, 2008
  8. Kim, Gwang-Man. Lee, In-Hyeok., the Story of Engineer Architectural Execution, 2007
  9. EnergyPlus Engineering Reference, Lawrence Berkeley National Laboratory, p.1117 Sandia Photovoltaic Performance Model, Oct 2010,
  10. Frederick C. Winkelmann, Modeling Windows in Energy Plus, IBPSA, Building Simulation, Sept 2011
  11. Yazdanian, M. and J.H. Klems, Measurement of the Exterior Convective Film Coefficient for Windows in Low-Rise Buildings, ASHRAE Transactions, Vol. 100 Part 1, p.1087, 1994
  12. B.T.Griffith, Photovoltaic and Solar Thermal Modeling with the Energy Plus Calculation Engine, July 2004
  13. Stephen K Wittkopf, Development of a Solar radiation and BIPV Design tool as EnergyPlus Plugin for Google Sketchup, July 2009
  14. D.L King, W.E. Boyson, J.A Kratochvil, 2004, Photovoltaic Array Performance Model, Sandia National Labs,

Cited by

  1. The Characteristics on CIGS Thin Film PV Module for Curtain Wall Spandrel Applications vol.33, pp.3, 2013, https://doi.org/10.7836/kses.2013.33.3.107
  2. 반투과형 태양전지를 이용한 창호형 BIPV 건물의 환경성능 분석 vol.11, pp.1, 2012, https://doi.org/10.5804/lhij.2020.11.1.087