DOI QR코드

DOI QR Code

생활폐기물 소각시 요구되는 요소수의 대체물질로 음식물 폐수 속의 암모니아 적용에 관한 연구

A Study on Investigate the Suitability of ${NH_4}^+$ Applications of Food Waste Water Instead of Urea in the Incineration of Municipal Solid Waste

  • 고성규 (한서대학교 환경공학과) ;
  • 조용균 (한서대학교 환경공학과) ;
  • 이영신 (한서대학교 환경공학과)
  • Go, Sung Gyoo (Department of Environmental Engineering, Hanseo University) ;
  • Cho, Yong Kun (Department of Environmental Engineering, Hanseo University) ;
  • Lee, Young Shin (Department of Environmental Engineering, Hanseo University)
  • 발행 : 2012.12.31

초록

본 연구는 음식물류 폐기물의 처리과정에서 발생하는 음식물류 폐수를 생활폐기물 소각시설에서 생활폐기물과 음식물류폐수를 혼합하여 소각처리 방법과 소각시 음식물류 폐수를 이용한 질소산화물 제거 및 배출가스의 영향등을 조사하였다. 해양투기용으로 발생된 음식물류폐기물 폐수는 성상이 94-96%의 함수율을 갖고 있다. 음식물류폐기물 폐수를 주입하였을 때 소각로 출구 온도는 $897^{\circ}C$이였으며, 평상시는 $925^{\circ}C$로 약 $28^{\circ}C$도 떨어졌다. 음식물류폐기물 폐수를 각각 $200{\ell}/hr$, $300{\ell}/hr$ 투입시 질소산화물의 평균배출농도는 각각 50ppm, 46ppm 이었다. 연관식 폐열보일러는 음식물류 폐수의 투입량이 많을수록 튜브 막힘 현상이 있었으며, 막힘 튜브는 압축공기를 이용한 튜브 청소로 원상태를 유지 할 수 있어 연속적 소각에는 방해가 되지 않았다. 유기성 폐기물인 음식물류 폐수의 자원화 처리방법과 더불어 기존 소각시설을 이용한 소각처리가 육상처리의 한 방법으로 자리매김 할 수 있으며, 소각시 배출가스의 질소산화물이 제거됨으로써 질소산화물 제거용 암모니아, 요소수 등 화학약품비용 절감하는 효과도 있는 것으로 나타났다.

This study examined for possibility of the food wastewater incineration treatment method as one of overland treatment method by incineration through liquefied spray of food wastewater when incinerating domestic wastes under operation and for the relationship, etc of air discharge material discharged in incineration, and the results of study are as follow: The food wastewater as one of overland treatment method was analysed 94-96% of moisture contents. Temperature of incinerator outduct during mixed incineration of food wastewater with MSW was average $897^{\circ}C$ and incineration of only MSW was $925^{\circ}C$. Temperature of the mixed incineration of food wastewater was dropped about $28^{\circ}C$ by incineration of only MSW. Concentration of nitrogen oxides(NOx) among air discharge gases was studied by 50ppm, 46ppm when inputting $200{\ell}/hr$, $300{\ell}/hr$ into the incinerator as the quantity of food wastewater. In the mixed incineration of food wastewater, generation speed of scales in the inside of a tubular exhaust gas boiler became rapid and the scale generation quantity became large but the exhaust gas boiler normally operated since scales were removed in cleaning of the tube with a compressive air cleaning facility and there was no opening clogging phenomena in a filter cloth of the filtering dust collector. The overland treatment method, not ocean dumping of food wastewater can be proposed as a technology since mixed incineration of food wastewater with MSW in the existing domestic waste incineration plant is possible, and operation costs of the incineration facility were reduced since use of chemicals such as ammonia and urinary hydrogen ion excretion, etc used in incineration facilities for removing nitrogen oxides(NOx).

키워드

참고문헌

  1. 환경부, 2009전국폐기물 발생 및 처리현황, (2010).
  2. 정우영, 해양환경공학, 동화기술, (2008).
  3. 국토행양부, 육상폐기물 해양투기 종합대책, pp. 11-12. (2006).
  4. 환경부, 2011년 전국 생활폐기물 자원 회수시설 현황. (2012).
  5. 고광백 외 11명, 폐수처리공학, 동화기술, (2004).