DOI QR코드

DOI QR Code

Evaluation of daylighting performance of bar-type mirror reflector system in tunnel

터널 적용 바형식 반사거울시스템의 채광성능 평가

  • Received : 2012.01.13
  • Accepted : 2012.01.25
  • Published : 2012.01.31

Abstract

The basic study was preceded for reducing maintenance and power cost of lighting fixture applying daylighting because most of the tunnel lighting depend on the artificial lighting. This study aims to evaluate the daylighting performance of daylighting performance of bar-type mirror reflector system in tunnel. Illuminance and luminance was measured. As a result of horizontal illuminance measurements, it was satisfied in tunnel recommended illuminance (KSA 3703) that total average was 1,170 lx increased 6.5 times more than this system was not used. Also, as a result of evaluating driver's glare on the opposite lane, glare did not occur and the luminance ratio was 3.01 which satisfies the luminance ratio standard 10.

대부분의 터널 조명은 인공조명에 의존하고 있어 조명설비의 유지관리비 및 전력비를 절감하기 위해 자연채광을 적용한 기초연구가 선행되었다. 이에 본 연구는 터널 조경 바형식 반사거울시스템의 채광성능(조도, 휘도)을 평가하였다. 수평면 조도를 측정한 결과, 전체 평균 1,170 lx로 미설치 대비 6.5배 이상 증가하여 채광유효구간에서 구간별 터널기준조도(KSA 3703)를 만족시키는 것으로 나타났으며, 터널 밖으로 나오는 반대편 차로 운전자의 휘도를 측정하여 분석한 결과, 전체 평균 3.01로 현휘 기준치인 10 이내로 평가되어 눈부심이 발생하지 않는 것으로 나타났다.

Keywords

References

  1. 이범석 (2005), "태양광 채광시스템에 의한 실내공간의 빛환경 특성", 한국생태환경건축학회 춘계학술발표회 논문집, 제5권, 제1호, pp. 109-116.
  2. 이범석 (2011), "시뮬레이션 분석을 통한 반사거울시스템의 터널 적용성 연구", 한국터널지하공간학회논문집, Vol. 13, No. 5, pp. 371-383.
  3. 이은풍 (2006), "터널조명시스템에서의 에너지절약을 위한 기법연구", 한국터널지하공간학회논문집, 제8권, 제4호, pp. 85-98.
  4. 정명순 (2011), "터널의 조명환경 개선을 위한 반사거울시스템의 위치 선정에 관한 기초연구", 한국터널지하공간학회논문집, Vol. 13, No. 5, pp. 385-393.