Reliability Assessment Criteria of Reflector for Lamp of BLU(Back Light Units)

BLU(Back Light Units) 램프 반사갓의 신뢰성평가기준

  • Park, Chang-Kyu (Reliability Assessment Center, Korea Institute of Lighting Technology) ;
  • Jeong, Hee-Suk (Reliability Assessment Center, Korea Institute of Lighting Technology) ;
  • Jeong, Hai-Sung (Dept. of Multimedia Engineering Seowon Univ.)
  • 박창규 (한국조명기술연구소 신뢰성평가센터) ;
  • 정희석 (한국조명기술연구소 신뢰성평가센터) ;
  • 정해성 (서원대학교 멀티미디어공학과)
  • Received : 2010.10.15
  • Accepted : 2010.11.27
  • Published : 2011.03.25

Abstract

Many domestic manufacturers make reflectors for Lamps of BLU(back light units). However, color change and parting occur as a result of diverse usage environment. Therefore, many of the manufacturers are reluctant in R&D investment of reflectors for Lamps of BLU. Hence, in this article reliability assessment criteria for reflector for lamp of BLU are established in terms of performance test, environment test and life test.

Keywords

References

  1. 김명수, 유동수 (2001), 신뢰성평가를 위한 기본 개념과 시험조건 결정, 제2회 부품․소재 신뢰성워크샵
  2. ASTM E 1651-94 (2004), Standard Test Method for Total Luminous Reflectance Factor by Use of 30/t Integrating-Sphere Geometry (Withdrawn 2004).
  3. KS C 1303-2 (2000), 직동식 지시 전기 계기 제2부:전류계 및 전압계.
  4. KS C 1303-3 (2000), 직동식 지시 전기 계기 제3부:전력계 및 무효전력계
  5. KS C IEC 60050-845 (2009), 국제전기기술용어 - 제845장 : 조명.
  6. KS Q 1003 (2006), 랜덤 샘플링 방법.