무치악 환자에서 CAD/CAM을 이용한 임플란트 식립($NobelGuide^{TM}$) 및 즉시하중 증례

Restoration of an Edentulous Patient with CAD/CAM Guided Implant Surgery ($NobelGuide^{TM}$) and Immediate Loading: Case Report

  • 고경호 (강릉원주대학교 치과대학 보철학교실 및 구강과학연구소) ;
  • 임광길 (강릉원주대학교 치과대학 보철학교실 및 구강과학연구소) ;
  • 김대곤 (강릉원주대학교 치과대학 보철학교실 및 구강과학연구소) ;
  • 박찬진 (강릉원주대학교 치과대학 보철학교실 및 구강과학연구소) ;
  • 조리라 (강릉원주대학교 치과대학 보철학교실 및 구강과학연구소)
  • Ko, Kyoung-Ho (Department of Prosthodontics and Research Institute of Oral Science, Gangneung-Wonju National University) ;
  • Lim, Kwang-Gil (Department of Prosthodontics and Research Institute of Oral Science, Gangneung-Wonju National University) ;
  • Kim, Dae-Gon (Department of Prosthodontics and Research Institute of Oral Science, Gangneung-Wonju National University) ;
  • Park, Chan-Jin (Department of Prosthodontics and Research Institute of Oral Science, Gangneung-Wonju National University) ;
  • Cho, Lee-Ra (Department of Prosthodontics and Research Institute of Oral Science, Gangneung-Wonju National University)
  • 투고 : 2011.02.12
  • 심사 : 2011.06.25
  • 발행 : 2011.06.30

초록

임플란트 시술에서 CAD/CAM을 포함한 컴퓨터 기술의 발달은 단순히 임플란트를 보다 정확하고, 예측 가능하게 식립하는 것뿐 아니라, 무피판(flapless) 수술과 즉시하중을 가능하게 하였다. 그러므로 술후 출혈과 불편감의 감소 및 시술시간과 치유기간을 단축시키는 장점이 있으며, 시술 후 즉시 보철물을 장착해 줌으로써 환자의 구강기능을 단기간에 회복시키고 경조직과 연조직의 형태를 보존하여 최종보철 시 유리한 환경을 만들어 줄 수 있게 되었다. 본 증례는 상 하악 무치악 상태로 내원한 40세 남성 환자로 하악 총의치의 불안정성 및 불편감 등을 호소하였으며, 하악에 임플란트 지지 고정성 보철물을 통한 수복을 원하였다. 충분한 골량, 환자의 참여도, 경제적인 여건, 전신적인 건강 등을 고려하여 하악에는 CAD/CAM 기반의 수술용 스텐트를 이용한 수술 및 미리 제작된 고정성 임시보철물을 이용하여 즉시하중을 부여하는NobelGuide 보철을 계획하였으며, 상악에는 총의치를 계획하였다. 환자의 안모를 평가하여 임시의치를 제작하였으며, 복제한 임시의치를 바탕으로 스텐트를 제작하고, 컴퓨터단층촬영을 시행하였다. 3차원으로 변환된 영상을 기반으로 하악에 7개의 고정체를 생역학적 조건과 치조골의 상태에 맞게 분산 배치하였다. 제작된 수술용 스텐트에 맞게 주모형을 제작하고, 임시고정성 보철물을 제작하여 장착함으로써 즉시하중을 부여하였다. 식립 3개월 후 골유착 정도를 평가하고 최종보철물을 제작하였다. 추후 발생할 수 있는 상악 골흡수를 방지하기 위해 주기적인 내원 및 검사를 통해 성공적인 치료가 될 수 있도록 노력하였다.

With the use of computed tomography (CT), computer-aided design/computer-assisted machining (CAD/CAM) technology and internet, the implant dentistry has been evolved. The surgical templates made by CAD/CAM technology and precise installation of implants, permit restorations to be inserted immediately after implants have been placed. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla and mandible received 7 implants in mandible using CAD/CAM surgical templates. Prefabricated provisional fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics and function during 6 months. Definitive prostheses were fabricated. At 6 months recall appointment, patient's occlusion was slightly changed. To prevent additional adverse effect, regular check-up and occlusal adjustment would be needed.

키워드

참고문헌

  1. Adell R, Lekholm U, Rockler B and Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10:387-416. https://doi.org/10.1016/S0300-9785(81)80077-4
  2. Szmukler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000;11:12-25. https://doi.org/10.1034/j.1600-0501.2000.011001012.x
  3. Gapski R, Wang HL, Mascarenhas P and Lang NP. Critical review of immediate implant loading. Clin Oral Implants Res 2003;14:515-427. https://doi.org/10.1034/j.1600-0501.2003.00950.x
  4. Ostman PO. Immediate/early loading of dental implants. Clinical documentation and presentation of a treatment concept. Periodontol 2000 2008:47; 90-112. https://doi.org/10.1111/j.1600-0757.2007.00244.x
  5. Degidi M, Piattelli A, Felice P, and Carinci F. Immediate functional loading of edentulous maxilla; a 5-year restrospective study of 388 titanium implants. J Periodontol 2005;76:1016-24. https://doi.org/10.1902/jop.2005.76.6.1016
  6. Horiuchi K, Uchida H, Yamamoto K, Sugimura M. Immediate loading of Branemark system implants following placement in edentulous patients: a clinical report. Int J Oral Maxillofac Implants 2000;15: 824-30.
  7. Bergkvist G, Sahlholm S, Karlsson U, Nilner K, Lindh C. Immediately loaded implants supporting fixed prostheses in the edentulous maxilla: a preliminary clinical and radiologic report. Int J Oral Maxillofac Implants 2005;20:399-405.
  8. Aalam AA, Nowzari H, Krivitsky A. Functional restoration of implants on the day of surgical placement in the fully edentulous mandible: a case series. Clin Implant Dent Relat Res 2005;7:10-6. https://doi.org/10.1111/j.1708-8208.2005.tb00041.x
  9. Wolfinger GJ, Balshi TJ, Rangert B. Immediate functional loading of Brånemark system implants in edentulous mandibles: clinical report of the results of developmental and simplified protocols. Int J Oral Maxillofac Implants 2003;18:250-7.
  10. Ioannidou E, Doufexi A. Does loading time affect implant survival? A meta-analysis of 1,266 implants. J Periodontol 2005;76:1252-8. https://doi.org/10.1902/jop.2005.76.8.1252
  11. Fuster-Torres MA, Albalat-Estela S, Alcañiz-Raya M, Penarrocha-Diago M. CAD / CAM dental systems in implant dentistry: update. Med Oral Patol Oral Cir Bucal 2009;14:141-5.
  12. Strub JR, Rekow ED, Witkowski S. Computer-aided design and fabrication of dental restorations: current systems and future possibilities. J Am Dent Assoc 2006;137:1289-96. https://doi.org/10.14219/jada.archive.2006.0389
  13. Verstreken K, Van Cleynenbreugel J, Marchal G, Naert I, Suetens P, van Steenberghe D. Computer- assisted planning of oral implant surgery: a three- dimensional approach. Int J Oral Maxillofac Implants 1996;11:806-10.
  14. Tee-Khin N, Cheng AC, Lee H, Wee AG, Leong EW. The management of a completely edentulous patient using simultaneous maxillary and mandibular CAD/CAM-guided immediately loaded definitive implant-supported prostheses: a clinical report. J Prosthet Dent 2008;99:416-20. https://doi.org/10.1016/S0022-3913(08)00069-3
  15. Balshi SF, Wolfinger GJ, Balshi TJ. Surgical planning and prosthesis construction using computed tomography, CAD/CAM technology, and the Internet for immediate loading of dental implants. J Esthet Restor Dent 2006;18:312-23. https://doi.org/10.1111/j.1708-8240.2006.00029.x
  16. Kupeyan HK, Shaffner M, Armstrong J. Definitive CAD/CAM-guided prosthesis for immediate loading of bone-grafted maxilla: a case report. Clin Implant Dent Relat Res 2006;8:161-7. https://doi.org/10.1111/j.1708-8208.2006.00018.x
  17. van Steenberghe D, Glauser R, Blombäck U, Andersson M, Schutyser F, Pettersson A, Wendelhag I. A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. Clin Implant Dent Relat Res 2005;7 Suppl 1:S111-20 https://doi.org/10.1111/j.1708-8208.2005.tb00083.x
  18. Marchack CB. An immediately loaded CAD/CAM- guided definitive prosthesis: a clinical report. J Prosthet Dent 2005;93:8-12. https://doi.org/10.1016/j.prosdent.2004.10.012
  19. Dreiseidler T, Neugebauer J, Ritter L, Lingohr T, Rothamel D, Mischkowski RA, Zöller JE. Accuracy of a newly developed integrated system for dental implant planning. Clin Oral Implants Res 2009;20:1191-9. https://doi.org/10.1111/j.1600-0501.2009.01764.x
  20. Eggers G, Patellis E, Mühling J. Accuracy of template-based dental implant placement. Int J Oral Maxillofac Implants. 2009;24:447-54.
  21. Park HS, Hwang JW. Implant overdenture & fixed complete prosthesis. 1st ed. Seoul: Well Pub. Co.; 2005.
  22. Sadowsky. The implant-supported prosthesis for the edentulous arch: Design considerations. J Prosthet Dent 1997;78:28-33 https://doi.org/10.1016/S0022-3913(97)70084-2
  23. van Steenberghe D, Naert I, Andersson M, Brajnovic I, Van Cleynenbreugel J, Suetens P. A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. Int J Oral Maxillofac Implants 2002;17:663-70.
  24. Yong LT, Moy PK. Complications of computer-aided- design / computer-aided-machining-guided (Nobel Guide) surgical implant placement: an evaluation of early clinical results. Clin Implant Dent Relat Res 2008;10:123-7. https://doi.org/10.1111/j.1708-8208.2007.00082.x
  25. Komiyama A, Klinge B, Hultin M. Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery. Clin Oral Implants Res 2008;19:677-85. https://doi.org/10.1111/j.1600-0501.2008.01538.x
  26. Gupta S, Lechner SK, Duckmanton NA. Maxillary changes under complete dentures opposing mandibular implant-supported fixed prostheses. Int J Prosthodont 1999;12:492-7.
  27. Valente F, Schiroli G, Sbrenna A. Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. Int J Oral Maxillofac Implants. 2009:24:234-42.