DOI QR코드

DOI QR Code

A Study on the Automatic Sensing Device for Gas Leakage of Cooling Plate Using the Microprocessor System

  • Wang, Jee-Seok (Division of Mechanical and Information Engineering, Korea Maritime University) ;
  • Yoon, Hee-Jong (Department of Research and Development, Hazon Co., Ltd.) ;
  • Kang, Ki-Seong (Department of Research and Development, Hazon Co., Ltd.) ;
  • Kim, Jong-Do (Division of Marine Engineering, Korea Maritime University)
  • 투고 : 2011.04.11
  • 심사 : 2011.05.21
  • 발행 : 2011.05.31

초록

The cooling water circulation plates had been used to drop the temperature of refractory outside shell of common cooling system by using cooling plate or stave type. When they are attacked by surrounding gas, they are corroded and the water flows in the refractory due to leakage of water. So, the life of refractory material is shortened and changed due to the worse conditions of cooling system. The automatic sensing device for water leakage of cooling plate is developed to check the position of trouble by using the microprocessor system when cooling water leak and gas are flowed into the cooling plate through the leakage position. The flowed gas is detected in the micro-process system which delivers the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave against the water leakage part immediately and then deliver the signal to main control room by using the microprocessor system and wireless-radio relay station. This system will be developed in changing the working condition from manual system to unmanned auto alarm system.

키워드

참고문헌

  1. E. Chanran, B. Maton and A. Four Ment, "Effect of Postural Muscle Fatigue on the Relation Between Segmental Posture and Movement", J. Electromyography and Kinesiology , vol. 12, pp. 67-69, 2002. https://doi.org/10.1016/S1050-6411(01)00027-X
  2. Vitasalo JHT, et al., "Signal Characteristics of EMG during Fatigue", Eur J Appl.Physiol, vol. 37, pp. 111-121, 1977. https://doi.org/10.1007/BF00421697
  3. C.J.De Luca, "The Use of Surface Electromyography in Biomechanics", J. Appl. Physiol. vol. 13, No. 2. pp. 135-163, 1997.
  4. The Freedonia Group, Inc., Power Supplies for Portable Products to 2008, Pub Date, 2004.
  5. H.L. Garner, "Number systems and arithmetic", Advenced in Computers, vol. 6, pp. 131-194, 1975.
  6. S. Bahng, Y. Park and J. Kim, "QR-LRL signal detection for spatially multiplexed MIMO system," IEICE TRANS. Commun., vol. E91-B, No.10, pp. 3383-3386, 2008. https://doi.org/10.1093/ietcom/e91-b.10.3383