Acknowledgement
Supported by : 중소기업청
References
- Ludwig B, Baumgaertel S, Bowman SJ. Mini-implants in orthodontics. Innovative anchorage concepts. 1st ed. London: Quintessence Publishing; 2008. p. 23.
- Ramaswamy R, Evans S, Kosashvili Y. Holding power of variable pitch screws in osteoporotic, osteopenic and normal bone: are all screws created equal? Injury 2010;41:179-83. https://doi.org/10.1016/j.injury.2009.08.015
- Saka B. Mechanical and biomechanical measurements of five currently available osteosynthesis systems of self-tapping screws. Br J Oral Maxillofac Surg 2000;38:70-5. https://doi.org/10.1054/bjom.1999.0230
- Miyawaki S, Koyama I, Inoue M, Mishima K, Sugahara T, Takano-Yamamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 2003;124:373-8. https://doi.org/10.1016/S0889-5406(03)00565-1
- Miyamoto I, Tsuboi Y, Wada E, Suwa H, Iizuka T. Influence of cortical bone thickness and implant length on implant stability at the time of surgery-clinical, prospective, biomechanical, and imaging study. Bone 2005;37:776-80. https://doi.org/10.1016/j.bone.2005.06.019
- Uhthoff HK. Mechanical factors influencing the holding power of screws in compact bone. J Bone Joint Surg Br 1973;55:633-9.
- Motoyoshi M, Hirabayashi M, Uemura M, Shimizu N. Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 2006;17:109-14. https://doi.org/10.1111/j.1600-0501.2005.01211.x
- BUchter A, Wiechmann D, Koerdt S, Wiesmann HP, Piffko J, Meyer U. Load-related implant reaction of mini-implants used for orthodontic anchorage. Clin Oral Implants Res 2005;16:473-9. https://doi.org/10.1111/j.1600-0501.2005.01149.x
- Park HS. Orthodontic treatment using micro-implant: clinical applications of micro-implant anchorage. Seoul: DaehanNare Publishing; 2006. p. 5-33.
- Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501.
- Yu WJ, Kyung HM. Torque and mechanical failure of orthodontic micro-implant influenced by implant design parameters. Korean J Orthod 2007;37:171-81.
- Chun HJ, Cheong SY, Han JH, Heo SJ, Chung JP, Rhyu IC, et al. Evaluation of design parameters of osseointegrated dental implants using finite element analysis. J Oral Rehabil 2002;29:565-74. https://doi.org/10.1046/j.1365-2842.2002.00891.x
- Hansson S, Werke M. The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study. J Biomech 2003;36:1247-58. https://doi.org/10.1016/S0021-9290(03)00164-7
- Nam OH, Yu WJ, Kyung HM. Cortical bone strain during the placement of orthodontic microimplant studied by 3D finite element analysis. Korean J Orthod 2008;38:228-39. https://doi.org/10.4041/kjod.2008.38.4.228
- Park JS, Yu WJ, Kyung HM, Kwon OW. Finite element analysis of cortical bone strain induced by self-drilling placement of orthodontic microimplant. Korean J Orthod 2009;39:203-12. https://doi.org/10.4041/kjod.2009.39.4.203
- You ZH, Bell WH, Schneiderman ED, Ashman RB. Biomechanical properties of small bone screws. J Oral Maxillofac Surg 1994;52:1293-302. https://doi.org/10.1016/0278-2391(94)90052-3
- Kincaid B, Schroder L, Mason J. Measurement of orthopedic cortical bone screw insertion performance in cadaver bone and model materials. Experimental Mechanics 2007;47:595-607. https://doi.org/10.1007/s11340-007-9056-6
- Krenn MH, Piotrowski WP, Penzkofer R, Augat P. Influence of thread design on pedicle screw fixation. Laboratory investigation. J Neurosurg Spine 2008;9:90-5. https://doi.org/10.3171/SPI/2008/9/7/090
- Brinley CL, Behrents R, Kim KB, Condoor S, Kyung HM, Buschang PH. Pitch and longitudinal fluting effects on the primary stability of miniscrew implants. Angle Orthod 2009;79:1156-61. https://doi.org/10.2319/103108-554R.1
- Motoyoshi M, Yano S, Tsuruoka T, Shimizu N. Biomechanical effect of abutment on stability of orthodontic mini-implant. A finite element analysis. Clin Oral Implants Res 2005;16:480-5. https://doi.org/10.1111/j.1600-0501.2005.01130.x
- Park HS, Jeong SH, Kwon OW. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2006;130:18-25. https://doi.org/10.1016/j.ajodo.2004.11.032
- Chen Y, Kyung HM, Zhao WT, Yu WJ. Critical factors for the success of orthodontic mini-implants: a systematic review. Am J Orthod Dentofacial Orthop 2009;135:284-91. https://doi.org/10.1016/j.ajodo.2007.08.017
- Song YY, Cha JY, Hwang CJ. Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness. Angle Orthod 2007;77:979-85. https://doi.org/10.2319/090606-363.1
- Song YY, Cha JY, Hwang CJ. Evaluation of insertion torque and pull-out strength of mini-screws according to different thickness of artificial cortical bone. Korean J Orthod 2007;37:5-15.
- Hwang CJ, Choi BJ, Kim KN, Kim KM, Lee YK. Orthodontic materials and clinical technique. Seoul: DaehanNare Publishing; 2003. p. 24.
Cited by
- The temporary anchorage devices research terrain: Current perspectives and future forecasts! vol.24, pp.1, 2018, https://doi.org/10.1053/j.sodo.2018.01.014
- A Brief Review on Micro-Implants and Their Use in Orthodontics and Dentofacial Orthopaedics vol.11, pp.22, 2011, https://doi.org/10.3390/app112210719