Abstract

A hybrid electromagnetic actuator with an air mount is designed so as to achieve the desired isolation reduce the vibration efficiency on the floor vibration. The performance specification of the hybrid electromagnetic actuator is determined based on the vibration criterion for vibration-sensitive equipment. In the design stage of the electromagnetic actuator, the simple reluctance method is adapted to analyze magnetic circuits. The result is verified by finite element analysis using ANSYS Emag. Finally, in order to confirm the design performance, a dynamic characteristic test is carried out for the prototype of a hybrid electromagnetic actuator.

Keywords

References

  1. Jang, H. K., Hong, S. I., Kim, H. S., Lee, D. H. and Lee, K. D., 2006, A Vibration Isolation System Design for a Vibration-sensitive Equipment, Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 16, No. 3, pp. 307-312. https://doi.org/10.5050/KSNVN.2006.16.3.307
  2. An, C. H., Yim, K. H., Jin, K. B. and Rim, K. H., 2007, Active Control of Vibration Isolation Table Using Air-spring, Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 17, No. 7, pp. 565-571. https://doi.org/10.5050/KSNVN.2007.17.7.565
  3. Shin, Y. H., Oh, K. Y., Lee, J. H. and Kim, K. J., 2007, Performance Enhancement of Pneumatic Vibration Isolation Table in Low Frequency by Active Control, Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 17, No. 1, pp. 72-79. https://doi.org/10.5050/KSNVN.2007.17.1.072
  4. Sun, J. O., Shin, Y. H. and Kim, K. J., 2007, A Study on Response Analysis of 6-DOF Pneumatic Vibration Isolation Table by Transient Movements of Carriage on It, Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 17, No. 6, pp. 515-523. https://doi.org/10.5050/KSNVN.2007.17.6.515
  5. Kim, H. T., Kim, C. H., Lee, K. W., Lee, G. S., Son, S. W. and Chun, C. K., 2009, Performance Estimation of Active Electro-magnetic Isolator for Semiconductor Manufacturing Machine, Proceedings of the KSNVE Annual Spring Conference, pp. 579-580.
  6. Moon, S. J., Jung, H. J., Shin, Y. H., Jang, D. D., Jeong, J. A. and Moon, Y. J., 2011, Development of a Hybrid Mount System Combined Airspring with Piezostack Actuator for Microvibration, Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 21, No. 1, pp. 56-65. https://doi.org/10.5050/KSNVE.2011.21.1.056
  7. Gordon, C. G., 1991, Generic Criteria for Vibration-sensitive Equipment, Proceedings of SPIE Conference on Vibration Control and Metrology, pp. 71-85, San Jose, CA
  8. http://www.newport.com
  9. Amick, H., Gendreau, M., Busch, T. and Gordon, C. G., 2005, Evolving Criteria for Research Facilities: I - Vibration, Proceedings of SPIE Conference on Buildings for Nanoscale Research and Beyond, pp. 1-13.
  10. Braucer, J. R., 2006, Magnetic Actuators and Sensors, IEEE Magnetic Society, Wiley-Interscience.

Cited by

  1. A Comparative Study on the Dynamic Characteristics and Control Performances of Hybrid Mounts According to Element Configuration vol.22, pp.6, 2012, https://doi.org/10.5050/KSNVE.2012.22.6.556
  2. A Hybrid Structure of Dual Stators and a Pneumatic Spring for Resonance Control in an Air Mount vol.05, pp.03, 2013, https://doi.org/10.4236/jemaa.2013.53019
  3. New Mount with Moving-Coil-Type Electromagnetic Actuator for Naval Shipboard Equipment vol.23, pp.10, 2013, https://doi.org/10.5050/KSNVE.2013.23.10.885