• Title/Summary/Keyword: 열매체유

Search Result 14, Processing Time 0.029 seconds

A Study on the Actual Status of Heat Transfer oils in Industries for Process Safety Management (공정안전관리 사업장의 열매체유 사용실태에 관한 연구)

  • Lee, Keun Won;Lee, Joo Yeob
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.33-39
    • /
    • 2014
  • Heat transfer oils are used in applications such as chemical plant heating systems, refinery heat exchange systems, certain gas processes, injection molding systems, and pulp and paper processing. These oils are extremely stable and resistant to thermal and oxidative degradation. In the event of a spill or accidental release of heat transfer oils, it can be ignited easily when there is an ignition source. This study discusses the status of safety management through the actual status of the heat transfer oils to prevent fire and explosion accidents in industries for process safety management. The actual status of the heat transfer oils in process system of industries surveyed by a questionnaire developed. The results of this study can be used to help establishment of safety management to prevent fire and explosion accidents, such as the management of heat transfer oils, safe operation and maintenance in heat transfer oil processes.

Flammability and Thermal Stabilities of Heat Transfer Oils (열매체유의 인화성과 열안정성)

  • Lee, Keun-Won;Lee, Jung-Suk;Choi, Yi-Rac
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.82-87
    • /
    • 2011
  • Heat transfer oils are used in applications such as heating systems of chemical plant, refinery heat exchange systems, gas plant process, injection molding systems, and pulp and paper processing. These oils are extremely stable and resistance to thermal and oxidative degradation. In the event of a spill or accidental release of heat transfer oils, it can be ignite easily when there is an ignition source. This paper discusses the flammability and thermal stabilities of new and used oils. The flammability of the oils are assessed by measuring changes in flash point and auto ignition temperature. The thermal stability of oils are evaluated by the thermal screening unit ($TS^u$) and the differential scanning calorimeter (DSC). From the experimental results, it is suggested to give fire hazard characteristics to safe precautions for the proper use and treatment of heat transfer oils.

An Experimental Study on Heat Transfer Performance of Heating Medium Oil Fluidized Bed Heat Exchanger (열매체유 유동층 열교환기의 전열성능에 대한 실험적 연구)

  • Park, Sang-Il;Ko, Chang-Bok;Lee, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.146-151
    • /
    • 2015
  • The heat transfer performance of heating medium oil fluidized bed heat exchanger was measured. The operation variables were air flow rate, air inlet temperature, moisture content, water flow rate and water inlet temperature. The outside heat transfer coefficient was determined from the heat exchanger experiment and its experimental correlation was determined as a function of air velocity and viscosity of heating medium oil. Effect of viscosity was well agreed with the previous studies. Errors of the correlation equation was less than about 10% for outside heat transfer coefficient developed in this study when compared with the measured value. Hot water with the temperature greater than $77^{\circ}C$ could be produced by using the heating medium oil fluidized bed heat exchanger.

Simultaneous analysis of ethylene glycol and glycolic acid in bio-specimens by GC/MS (생체시료에서 GC/MS에 의한 에틸렌글리콜 및 대사체인 글리콜산 동시분석)

  • Lee, Joon-Bae;Park, Mee-Jung;Sung, Tae-Myung;Choi, Byung-Ha;You, Jae-Hoon;Shon, Shung-Kun;Paeng, Ki-Jung
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.544-550
    • /
    • 2010
  • Mistaking pink colored thermal oil for grape wine, a victim drank the oil to death which was analyzed to contain 39% of ethylene glycol. Thermal oil could be used for heat transfer to prevent the malfunction due to the high pressure in the boiler operated at high temperature when using water. Main component of thermal oil is known to be mineral oil or ethylene glycol. From the blood and other tissue of the victim from autopsy, ethylene glycol and its metabolite were simultaneously analyzed by GC/MS after extraction under acidic condition with acetonitrile followed by derivatization with BSTFA. About 0.2 g of the specimens were pretreated with 50 uL of 0.5 M HCl solution to keep acidic condition, then dehydrated with anhydrous sodium sulfate followed by concentration under nitrogen stream. Ethylene glycol and glycolic acid concentration in blood was measured to be $2,755\;{\mu}g/mL$ and $174\;{\mu}g/mL$ respectively. In other specimen, the concentration of ethylene glycol and glycolic acid was $860\;{\mu}g/g\sim1,290\;{\mu}g/g$ and $93\;{\mu}g/g\sim134\;{\mu}g/g$. Especially, crystal appeared in kidney which was supposed xalate from the metabolite of ethylene glycol.

흡수탑에서 VOCs 제거 기술개발을 위한 세정수의 특성연구

  • 김혜진;최상기;박문기;박상원;최성우
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2001.11a
    • /
    • pp.44-45
    • /
    • 2001
  • VOCs의 일종인 benzene을 흡수하기 위한 최적의 세정액으로 열매체유를 선정하여, 충진탑(Packed Tower), 흡수칼럼에 세정액만 채워 bubble 시킨 기포탑(Aeration Tower)와 충진물과 세정액을 채워 bubble 시킨 Combined Packed & Aeration Tower의 3가지 시스템을 비교한 결과 Combined Packed 쇼 Aeration Tower 시스템에서 benzene 흡수효율이 가장 좋았다.

  • PDF

Simulation Study on Liquid Air Energy Storage (LAES) System using Dual Refrigeration Cycles and Thermal Oil Circulation (냉매사이클과 열매체유 순환을 활용한 액화공기에너지저장 시스템 공정모사 연구)

  • Jang, Soonnam;Park, Jongpo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.63-73
    • /
    • 2018
  • Innovative technical process for Energy Storage System (ESS), Liquid Air Energy Storage system (LAES) is mature technologies based on the gas liquefaction process. In spite of many advantages such as high energy density, no geographical constraints, low investment costs and long useful life, the system has not yet widely commercialized due to low round trip efficiency. To improve RTE and acquire high yield of liquid air, various configurations of LAES process have been considered. In this research, dual refrigerants cycle (R-600a and methanol) for air liquefaction and thermal oil circulation for power generation via liquid air gasification have been applied to improve cycle performance significantly using Aspen HYSYS simulator.

A Study on the Actual Conditions of Safety Management in Thermal Oil System (열매체유 시스템의 안전관리 실태에 관한 연구)

  • Lee, Joo Yeob;Lee, Keun Won;Woo, In Sung
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.60-66
    • /
    • 2014
  • Depending on the progress of the industrial advances, the use of the thermal oil system in the utility system has been increased, which became an important part in the operation of the plant. However, fire or explosion have occurred due to lack of risk awareness and safety management, more frequently than we know. In this study, by using a questionnaire, actual conditions of safety management in thermal oil system is surveyed and analyzed, it is composed of general, a safety status of the thermal oil system component and the stage of recognition and management in the thermal oil system. These results of this study can be used as basic data to the safety management and the accident prevention of fire or explosion in the workplace.