DOI QR코드

DOI QR Code

증기분사에 의한 가스터빈 열병합발전 시스템의 성능과 운전조건 변화 - 압축기 작동 변화를 중심으로

Changes in Performance and Operating Condition of a Gas Turbine Combined Heat and Power System by Steam Injection - A Focus on Compressor Operation

  • 투고 : 2011.08.05
  • 심사 : 2011.10.04
  • 발행 : 2011.12.01

초록

This study simulated the effect of steam injection on the performance and operation of a gas turbine combined heat and power (CHP) system. A commercial simple cycle gas turbine was analyzed. A full off-design analysis was carried out to investigate the variations in not only engine performance but also the operating characteristics of the compressor caused by steam injection. Variation in engine performance and operation characteristics according to various operation modes were examined. First, the impact of full steam injection was investigated. Then, operations aiming to guarantee a minimum compressor surge margin, such as under-firing and partial steam injection, were investigated. The former and latter were turned out to be relatively superior to each other in terms of power and efficiency, respectively.

키워드

참고문헌

  1. Proietti, S., Arcioni, L. and Desideri, U., 2006, "Implementation of a system for the analysis and evaluation of advantages of distributed generation," ASME paper 2006, GT2006-90765, pp. 807-815.
  2. Jonsson, M., Yan, J., 2005, "Humidified gas turbines-a review of proposed and implemented cycles," Energy, Vol. 30, Issue 7, pp. 1013-1078. https://doi.org/10.1016/j.energy.2004.08.005
  3. Bolland, O., Stadaas, J. F., 1995, "Comparative evaluation of combined cycles and gas turbine systems with water injection, steam injection, and recuperation," Transactions of the ASME, Vol. 117, No. 1, pp. 138-145. https://doi.org/10.1115/1.2822294
  4. Rice, I. G., 1995, "Steam-injected gas turbine analysis: steam rates," Journal of engineering for gas turbines and power, Vol. 117, pp. 347-353. https://doi.org/10.1115/1.2814101
  5. Kim, T. S., Cho, M. K., Ro, S. T., Kauh, S. K., 1997, "Analysis of small steam injected gas turbine system with heat recovery," Trans. of the KSME(B), Vol. 21, No. 8, pp. 996-1008.
  6. Paepe, De M., Dick, E., 2000, "Cycle improvements to steam injected gas turbines," International journal of energy research, Vol. 24, pp. 1081-1107. https://doi.org/10.1002/1099-114X(20001010)24:12<1081::AID-ER641>3.0.CO;2-6
  7. Fischer, A. C., Frutschi, H. U., Haselbacher, H., 2001, "Augmentation of gas turbine power output by steam injection," ASME paper, 2001-GT-0107.
  8. Yadav, R., Kumar, P., 2003, "Comparative thermodynamic analysis of combined and steam injected gas turbine cycles," IJPGC2003-40118, pp. 531∼537.
  9. Bouam, A., Aissani, S., Kadi, R., 2008, "Combustion chamber steam injection for gas turbine performance improvement during high ambient temperature operations," Journal of engineering for gas turbine and power, Vol. 130, No. 4, pp. 1-10.
  10. Srinivas, T., Gupta, V.S.S.K.S. A., Reddy, B. V., 2008, "Sensitivity analysis of STIG based combined cycle with dual pressure HRSG," International journal of thermal sciences, Vol. 47, pp. 1226-1234. https://doi.org/10.1016/j.ijthermalsci.2007.10.002
  11. Lee, J. J., Jeon, M. S., Kim, T. S., 2010, "The influence of water and steam injection on the performance of a recuperated cycle microturbine for combined heat and power application," Applied energy, Vol. 87, pp. 1307-1316. https://doi.org/10.1016/j.apenergy.2009.07.012
  12. Enter Software. GateCycle ver 6.0, 2006.
  13. Kim, Y. S., Lee, J. J., Kim, T. S., Sohn, J. L., 2011, "Effects of syngas type on the operation and performance of a gas turbine in integrated gasification combined cycle," Energy Conversion and Management, Vol. 52, Issue 5, pp. 2262-2271. https://doi.org/10.1016/j.enconman.2011.01.009
  14. Erbes, M. R., Gay. R. R., 1989, "Gate/Cycle predictions of the off-design performance of combined-cycle power plants," ASME Winter Annual Meeting, Vol. 124, pp. 43-51.
  15. http://mysolar.cat.com/cda/files/304496/7/ds65gs.pdf
  16. Rocha, G., Reynolds, S., Brown, T., 2008, "Introduction of the TaurusTM65 industrial gas turbine for power generation," GT2008-51328.
  17. Ganapathy, V., 1985, "Heat-recovery boiler design for cogeneration," Oil & Gas Journal, pp. 116-125.
  18. Kehlhofer, R., 1978, "Calculation for part-load operation of combined gas/steam turbine plants," Brown Boveri Rev, Vol. 65, No. 10, pp. 672-679.

피인용 문헌

  1. Influence of steam injection and hot gas bypass on the performance and operation of a combined heat and power system using a recuperative cycle gas turbine vol.27, pp.8, 2013, https://doi.org/10.1007/s12206-013-0639-0
  2. 증기 분사 방식에 따른 가스터빈 시스템의 엑서지 해석 vol.28, pp.5, 2011, https://doi.org/10.7316/khnes.2017.28.5.570
  3. Online process monitoring and fault-detection approach based on adaptive neighborhood preserving embedding vol.52, pp.5, 2011, https://doi.org/10.1177/0020294019838580