Abstract
This paper presents the test results of 12 direct tensile specimens to investigate the effect of cover thickness on the tension stiffening behavior in axially loaded reinforced concrete tensile members. Six concrete cover thickness ratios are selected as a main experimental parameter. The results showed that, as cover thickness became thinner, more extensive split cracking along the reinforcement occurred and transverse crack spacing became smaller, making the effective tensile stiffness of thin specimens at the stabilized cracking stage to be much smaller than that of thick specimens. This observation is not implemented in the current design provisions, in which the significant reduction of tension stiffening effect can be achieved by applying thinner cover thickness. Based on the present results, a modified tension stiffening factor is proposed to account for the effect of the cover thickness.
이 논문은 인장증강효과에 대한 피복두께의 영향을 알아보기 위하여 실시한 12개의 축하중을 받는 직접인장 실험체의 실험 결과를 정리 분석한 것이다. 피복두께와 철근 직경의 비를 주 변수로 선정하여 6개의 서로 다른 피복 두께를 갖는 실험체를 제작하여 실험을 실시하였다. 실험 결과에 따르면 피복두께가 얇을수록 쪼갬균열의 영향이 크게 나타났으며, 인장증강효과와 균열간격이 감소하였다. 그리고 균열안정화 단계에서의 인장증강효과도 피복두께가 얇아질수록 감소하는 것을 확인하였다. 현행 설계기준의 인장증강효과 모델들은 피복두께의 변화에 따른 인장증강 거동의 차이를 반영할 수 없으며, 특히 피복두께가 얇을수록 인장증강효과가 감소하는 현상을 고려하지 못하고 있다. 따라서 이 연구에서 수행한 실험 및 분석 결과를 근거로 하여 인장증강효과에 피복두께의 영향을 반영할 수 있는 인장증강 계수 수정식을 제안하였다.