초록
The single-phase switched reluctance motor(SRM) generates the positive torque in the restricted section. So, it can not started by itself and the torque ripple is heavier than poly-phase. For self-starting and fixing rotating direction, the rotor should be placed at the rising inductance slope when stationary. The parking permanent magnet locates the rotor in the fixed position, which can be started by it-self. It is very simple and cost effective but has some drawbacks. It affects the rotor during the operation, so the characteristics of motor, such as a torque, speed, and ripple are changed to go bad. This paper presents the detent torque of parking magnet starting device through the finite element analysis and experiments. The finite element analysis is performed at incremental rotor positions over one detent torque cycle for any one pole. The prototype, fabricated in the previous research, is used for the experiments. The inductance, instant torque, and detent torque are calculated using the terminal voltage and phase current. Finally, the finite element analysis result and the experiment result are compared for analysis and validity.