DOI QR코드

DOI QR Code

송전 계통 감시 시스템을 위한 취약도 평가 방법 개발

Vulnerability Evaluation for Monitoring Wide Area Outage in Transmission Systems

  • 발행 : 2010.03.01

초록

Defense systems are needed to prevent catastrophic failures of a power grid due to cascaded events. Cascaded events can be occurred by power flow overload. Especially, it is the most dangerous problem that overload line is outage, because it can make the power system face danger of cascaded. In this paper, vulnerability evaluation for monitoring wide are outage is proposed using by configuration information of transmission systems. This method of vulnerability evaluation is considered direct effect and indirect effect of power flow, especially overload. What is more, it can be used when the configuration of power system changes, as simple fault occurs or maintenance of facility. In the case studies, the estimation and simulation network have been testified and analysed in PSSE and C programming.

키워드

참고문헌

  1. B.A. Carreras, V.E. Lynch, I. Dobson, D.E. Newman, "Critical points and transitions in an electric power transmission model for cascading failure blackout", Chaos, vol. 12, no. 4, December 2002, pp. 985-994. https://doi.org/10.1063/1.1505810
  2. P. Fairley. "The Inruly Power Grid", IEEE Spectrum. pp. 22-27, August 2004.
  3. Gregory S. Vassell, Fellow, IEEE, "Northeast Blackout of 1965", IEEE Power Engineering Review, pp. 4-8, January 1991.
  4. "NIGHT OF TERROR", TIME, pp. 24-26, July 25, 1977.
  5. C. W. Taylor, "Improving Grid Behavior. IEEE Spectrum. June 1999. pp. 40-45.
  6. J. Chen, J. S. Thorp and M. Parashar. "Analysis of Electric Power System Disturbance Data", Proceedings of the 34th Hawaii International Conference on System Science, 2001.
  7. A.G. Phadke and J.S. Thorp, "Expose Hidden Failure to Prevent Cascading Outages", IEEE Computer Application in Power, pp. 20-23, July 1996.
  8. Seong-Il Lim, Chen-Ching Liu, Seung-Jae Lee, Myeon-Song Choi and Seong-Jeong Rim. "Blocking of Zone 3 Relays to Prevent Cascaded Events", Power Systes. IEEE Transactions on Volume 23, pp. 747-754, May 2008. https://doi.org/10.1109/TPWRS.2008.919417
  9. Phadke, A.G and Thorp, J.S. "Expose hidden failures to prevent cascading outages in power systems", Computer Applications in Power. IEEE, pp 20-23, July 1996
  10. David C. Elizondo, J. de la Ree, Arun G. Phadke and Stan Horowitz, "Hidden Failures in Protection System and their Impact on Wide-area Disturbances", IEEE, 2001. pp 710-714.
  11. April 2000.U.S.-Canada Power System Outage Task Force, ""Final Report on the August 14, 2003 blackout in the United States and Canada". http://www.ferc.gov/, April, 2004.
  12. Carson W. Taylor, Bonneville Administration, "Improving Grid Behavior-The inglorious summer-of-1996 blackouts taught the west to improve emergency control and protection and to sharpen simulation techniques", IEEE SPECTRUM JUNE 1999, pp. 42-45.
  13. Seong-Il Lim, Han-Chuan Yuan, Seong-Jeong Rim, Seung-Jae Lee and Myeon-Song Choi "Adaptive Blinder for Distance Relay Based on Sensitivity Factors", IEEE 2006, pp. 22-26.