• Title/Summary/Keyword: 2.4 mm locking compression plate

Search Result 4, Processing Time 0.018 seconds

Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture (해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료)

  • Chung, Hyung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

Hook Plate Fixation for Isolated Greater Tuberosity Fractures of the Humerus

  • Lee, Kyoung-Rak;Bae, Ki-Cheor;Yon, Chang-Jin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.222-229
    • /
    • 2017
  • Background: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. Methods: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. Results: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were $156.7^{\circ}$, $152.2^{\circ}$, $61.1^{\circ}$, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. Conclusions: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.

The Volar Plating of Fracture of the Coronoid Process - Report of Two Cases - (구상돌기 골절에서 내측 접근법을 통한 전방 금속판 고정술 - 2예 보고 -)

  • Jung, Gu-Hee;Cho, Chul-Hyun;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.260-265
    • /
    • 2010
  • Purpose: To report the clinical results of two cases of coronoid process fractures that were treated with volar plating through a medial approach. Materials and Methods: Two fractures of the coronoid process that needed to be fixed were managed with open reduction and internal fixation through a medial approach using 2.4 mm locking compression plates (Compact Hand set$^{(R)}$, Synthes, Switzerland). The patients were followed up for 14 months and 17 months and were evaluated using the Mayo Elbow Performance Score (MEPS). Results: The MEPS was 95 for Case 1 and 100 for Case 2. Active elbow joint motions were $5^{\circ}-120^{\circ}$ (Case 1) and $0^{\circ}-130^{\circ}$ (Case 2). Supination and pronation fully recovered. Conclusion: Satisfactory results can be obtained in cases of coronoid process fractures because volar plating through a medial approach allows sound fixation and early mobilization of the elbow joint.

3.5 mm T-shaped LCP (Locking Compression Plate) Fixation for Unstable Distal Clavicular Fractures (3.5 mm T형 잠김 금속판을 이용한 원위 쇄골 골절의 치료 결과)

  • Lee, Churl-Woo;Kim, Hee-Chun;Roh, Jae-Young;Park, Young-Su
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • Purpose: To review the clinical and radiological results after an open reduction and internal fixation with a T-shaped LCP for unstable distal clavicle fractures. Materials and Methods: From February 2005 to June 2006, ten patients with distal clavicle Neer type II fractures were treated with an open reduction and internal fixation with a T-shaped LCP. Bony union was identified by plain radiography. The clinical results were analyzed according to the UCLA scoring system. Results: The mean time to fracture union was 9weeks and union was achieved in all cases. The mean UCLA score was 33.4 (30-35); excellent in 8 cases and good in 2 cases. In one case, loosening of one distal screw was occured and mild AC joint subluxation was observed in another case. Conclusion: 3.5 mm T-shaped LCP fixation is a useful technique for treating unstable distal clavicle fractures. This procedure provide stable fixation with no further AC joint injury.