Abstract

The bonded tendon was adopted to the reactor building of some operating nuclear power plants in Korea and the assessment of the effective prestress force on the bonded tendon is being issued as an important pending problem for continuous operation beyond their design life. The sensitivity analysis of various parameters was carried out to evaluate the effective prestress force using the system identification technique and the optimal parameters were determined for SI technique in this study. The 1/5 scaled post-tensioned concrete beams with the bonded tendon type were manufactured and in order to investigate the relationship of the natural frequency and the displacement to the effective prestress force, impact test, SIMO sine sweep test and bending test using the optical fiber sensor and the compact displacement transducer were carried out. As a result of tests, both the natural frequency and the displacement show the good relationship with the effective prestress force and both parameters are available for the SI technique to estimate the effective prestress force.

국내 가동 중 일부 원전의 원자로건물에 부착식 텐던이 설치되어 있고, 부착식 텐던에 대한 유효 긴장력 평가는 이들 원전의 계속운전을 위한 주요 현안으로 부각되고 있다. 따라서, 본 연구에서는 System Identification 기법을 이용한 부착식 텐던의 유효 긴장력 평가를 위하여, SI 기법에 유효한 주요 매개변수의 영향 평가를 수행하고 최적의 매개변수를 도출하였다. 본 연구를 위하여, 원자로건물 벽체의 1/5 축소모형 시험체를 제작하였고, 유효 긴장력과 고유진동수 및 변위와의 상관성을 분석하기 위하여 Impact test, SIMO sine sweep test 및 광섬유센서와 변위계에 의한 휨시험을 수행하였다. 시험결과, 고유진동수와 변위 모두 유효 긴장력과 좋은 상관성을 지니는 것으로 나타나, 이들 매개변수 모두 SI 기법의 입력자료로 활용되어 부착식 텐던의 유효 긴장력 예측이 가능한 것으로 분석되었다.

Keywords

References

  1. 산업자원부(2005) 광섬유를 이용한 원전 격납건물 변형량 계측기술 및 변형 특성, 최종보고서.
  2. 장정범, 이홍표, 황경민, 송영철(2009) 부착식 텐던의 유효 긴장력 예측을 위한 매개변수 연구, 한국원자력학회 2009 추계학술발표회 논문집, 한국원자력학회.
  3. 통상산업부(1994) 차세대 원자로 기술개발(I), 최종보고서.
  4. 한국수력원자력(주)(2006) 월성 1 호기 수명관리 연구(II), 중간보고서.
  5. Abraham, M.A., Park, S.Y., and Stubbs, N. (1995) Loss of prestress prediction on nondestructive damage location algorithms, SPIE, Smart Structures and Materials 2446, pp. 60-67.
  6. Hamed, E. and Frostig, Y. (2006) Natural frequencies of bonded and unbonded prestressed beam-prestress force effects, Journal of Sound and Vibration 295, pp. 28-39. https://doi.org/10.1016/j.jsv.2005.11.032
  7. Kim, J.T., Ryu, Y.S., Cho, H.M., and Stubbs, N. (2003) Damage Identification in beam-type structures : frequency - based method vs mode - shape - based method, Engineering Structures 25, pp. 57-67. https://doi.org/10.1016/S0141-0296(02)00118-9
  8. Law, S.S. and Lu, Z.R. (2005) Time domain responses of a prestressed beam and prestress identification, Journal of Sound and Vibration, pp. 1011-1025.
  9. Lu, Z.R. and Law, S.S. (2006) Identification of prestress force from measured structural responses, Mechanical Systems and Signal Processing 20, pp. 2186-2199. https://doi.org/10.1016/j.ymssp.2005.09.001
  10. Maaskant, R., Alavie, T., Measures, R., Tadros, G., Rizkalla, S., and Guha-Thakurta, A. (1997) Fibre-optic bragg grating sensors for bridge monitoring, Cem. Concr. Compos. Vol. 19, pp. 21-23. https://doi.org/10.1016/S0958-9465(96)00040-6
  11. NCHRP (1999) Nondestructive Methods for Condition Evaluation of Prestressing Steel Strands in Concrete Bridges, Final report.
  12. Saiidi, N., Douglas, B., and Feng, S. (1994) Prestress force effect on vibration frequency of concrete bridges, Journal of Structural Engineering, Vol. 120, No. 7, pp. 2233-2241. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:7(2233)
  13. Unger, J.F., Teughels, A., and Roeck, G.D. (2006) System identification and damage detection of a prestressed concrete beam, Journal of Structural Engineering, ASCE, pp. 1691-1698.