References
- Schilder H, Yee FS. Canal debridement and disinfection. In: Cohen S, Burns RC, eds. Pathways of the Pulp, 3rd ed. St. Louis : MO Mosby 1984;175p.
- Pettiette MT, Delano EO, Trope M. Evaluation of success rate of endodontic treatment performed by students with stainless-steel K-files and nickeltitanium hand files. J Endod 2001;27:124-127. https://doi.org/10.1097/00004770-200102000-00017
- Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 1998;14(7):346-351.
- Schafer E, Schulz-Bongert U, Tulus G. Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study. J Endod 2004;30(6):432-435. https://doi.org/10.1097/00004770-200406000-00014
- Chen JL, Messer HH. A comparison of stainless steel hand and rotary nickel-titanium instrumentation using a silicone impression technique. Aust Dent J 2002;47(1):12-20. https://doi.org/10.1111/j.1834-7819.2002.tb00297.x
- Garip Y, Gunday M. The use of computed tomography when comparing nickel-titanium and stainless steel files during preparation of simulated curved canals. Int Endod J 2001;34(6):452-457. https://doi.org/10.1046/j.1365-2591.2001.00416.x
- Glosson CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. J Endod 1995;21(3):146-151. https://doi.org/10.1016/S0099-2399(06)80441-3
- K3 Endo overview. 2002. Available at: http://www.SybronEndo.com.
- Bergmans E, Van Cleynenbreugel J, Wevers M, Lambrechts P. Mechanical root canal preparation with Ni-Ti rotary instruments: rationale, performance and safety. Status report for the American Journal of Dentistry. Am J Dent 2001;14(5):324-333.
- Ayar L, Love R. Shaping ability of ProFile and K3 rotary Ni-Ti instruments when used in a variable tip sequence in simulated curved root canals. Int Endod J 2004;37:593-601. https://doi.org/10.1111/j.1365-2591.2004.00851.x
- Bergmans L, Van Cleynenbreugel J, Beullens M, Wevers M, Van Meerbeek B, Lambrechts Progressive versus constant tapered shaft design using Ni-Ti rotary instruments. Int Endod J 2003;36(4):288-295. https://doi.org/10.1046/j.1365-2591.2003.00650.x
- Kim TO, Cheung GSP, Lee JM, Kim BM, Hur B, Kim HC. Stress distribution of three Ni-Ti rotary files under bending and torsional conditions using a mathematic analysis. Int Endod J 2009;42:14-21. https://doi.org/10.1111/j.1365-2591.2008.01481.x
- Kim HC, Cheung GS, Lee CJ, Kim BM, Park JK, Kang SI. Comparison of forces generated during root canal shaping and residual stresses of three nickel-titanium rotary files by using a threedimensional finite-element analysis. J Endod 2008;34(6):743-747. https://doi.org/10.1016/j.joen.2008.03.015
- Lightspeed recommended technique guide. San Antonio, TX: Lightspeed Technology 1994.
- Thompson SA, Dummer PH. Shaping ability of Lightspeed rotary nickel-titanium instruments in simulated root canals. Part 1. J Endod 1997;23(11):698-702. https://doi.org/10.1016/S0099-2399(97)80405-0
- Thompson SA, Dummer PH. Shaping ability of Lightspeed rotary nickel-titanium instruments in simulated root canals. Part 2. J Endod 1997;23(12):742-747. https://doi.org/10.1016/S0099-2399(97)80347-0
- Portenier IF, Lutz F, Barbakow F. Preparation of the apical part of the root canal by the Lightspeed and step-back techniques. Int Endod J 1998;31(2):103-111. https://doi.org/10.1046/j.1365-2591.1998.00116.x
- Tharuni SL, Parameswaran A, Sukumaran VG. A comparison of canal preparation using the K-file and Lightspeed in resin blocks. J Endod 1996;22(9):474-476. https://doi.org/10.1016/S0099-2399(96)80081-1
- Knowles KI, Hammond NB, Biggs SG, Ibarrola JL. Incidence of instrument separation using LightSpeed rotary instruments. J Endod 2006;32(1):14-16. https://doi.org/10.1016/j.joen.2005.10.008
- Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 1974;18(2):269-296.
- Hartmann MS, Barletta FB, Camargo Fontanella VR, Vanni JR. Canal Transportation after Root Canal Instrumentation: A Comparative Study with Computed Tomography. J Endod 2007;33(8):962-965. https://doi.org/10.1016/j.joen.2007.03.019
- Weine FS, Kelly RF, Lio PF. The effect of preparation procedures on original canal shape and on apical foramen shape. J Endod 1975;1(8):255-262. https://doi.org/10.1016/S0099-2399(75)80037-9
- Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg 1971;32:271-275. https://doi.org/10.1016/0030-4220(71)90230-1
- Cohen S, Hargreaves KM. Cleaning and shaping root canal systems. Pathways of the pulp. 9th ed. St. Louis : MO Mosby 2006;306p.
- Dummer PMH, Alodeh MHA, AI-Omari MAO. A method for the construction of simulated canals in clear resin blocks. Int Endod J 1991;24(2):63-66. https://doi.org/10.1111/j.1365-2591.1991.tb00809.x
- Tharuni SL, Parameswaran A, Sukumaran VG. A Comparison of Canal Preparation Using the K-File and Lightspeed in Resin Blocks. J Endod 1996;22(9):474-476. https://doi.org/10.1016/S0099-2399(96)80081-1
- Griffiths IT, Bryant ST, Dummer PM. Canal shapes produced sequentially during instrumentation with Quantec LX rotary nickeltitanium instruments: a study in simulated canals. Int Endod J 2000;33(4):346-354. https://doi.org/10.1046/j.1365-2591.2000.00311.x
- Thompson SA, Dummer PH. Shaping Ability of Lightspeed Rotary Nickel-Titanium Instruments in Simulated Root Canals. Part 2. J Endod 1997;23(12):742-747. https://doi.org/10.1016/S0099-2399(97)80347-0
- Turpin YL, Chagneau F, Bartier , Cathelineau G, Vulcain JM. Impact of torsional and bending inertia on root canal instruments. J Endod 2001;27(5):333-336. https://doi.org/10.1097/00004770-200105000-00006
- Thompson SA, Dummer PH. Shaping Ability of Lightspeed Rotary Nickel-Titanium Instruments in Simulated Root Canals. Part 1. J Endod 1997;23(11):698-702. https://doi.org/10.1016/S0099-2399(97)80405-0
- Barbakow F. The LightSpeed System. Dent Clin North Am 2004;48(1):113-135. https://doi.org/10.1016/j.cden.2003.10.003
- Walsch H. The hybrid concept of nickel-titanium rotary instrumentation. Dent Clin North Am 2004;48(1):183-202. https://doi.org/10.1016/j.cden.2003.11.003