• Title/Summary/Keyword: ProTaper Universal

Search Result 21, Processing Time 0.03 seconds

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.

Effect of Internal Stress on Cyclic Fatigue Failure in ProTaper Universal (ProTaper Universal에 축적된 내부 응력이 피로 파절에 미치는 영향)

  • Jo, Yun-Sung;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.57-66
    • /
    • 2012
  • The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of ProTaper Universal. ProTaper Universal (Dentsply Maillefer) S1, S2, F1, F2, F3, F4 and F5 (25 mm length) were used in this study. To give the internal stress, the ProTaper Universal were put into the .02 taper Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. The rotation speed was 300 rpm and torque value was 1.0 Ncm. ProTaper Universal were grouped by the induced number of internal stress and randomly distributed among one control group and three experimental groups (n=10). The four groups were Stress 0 (control), Stress 1, Stress 2 and Stress 3. These instruments were rotated until separation. For cyclic fatigue measurement, inclined plane was used and time for separation was recorded. It was statistically analyzed using two-way ANOVA and Duncan post-hoc test at 95% confidential level. In all ProTaper Universal, there was statistically significant decrease on time for separation in Stress 3. In F2 and F3, there were statistically significant difference between control group and all experimental groups. And in F4 and F5, Stress 2 and 3 groups showed significantly lower cyclic fatigue resistance from Stress 0 group. In the limitation of this study, cyclic fatigue failure of ProTaper Universal is influenced by accumulated internal stress.

STRESS DISTRIBUTION OF THREE NITI ROTARY FILES UNDER BENDING AND TORSIONAL CONDITIONS USING 3-DIMENSIONAL FINITE ELEMENT ANALYSIS (세가지 니켈 티타늄 파일의 휨과 비틀림 조건에서의 응력 분포에 관한 3차원 유한요소 연구)

  • Kim, Tae-Oh;Lee, Chan-Joo;Kim, Byung-Min;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.323-331
    • /
    • 2008
  • Flexibility and fracture properties determine the performance of NiTi rotary instruments. The purpose of this study was to evaluate how geometrical differences between three NiTi instruments affect the deformation and stress distributions under bending and torsional conditions using finite element analysis. Three NiTi files (ProFile .06 / #30, F3 of ProTaper and ProTaper Universal) were scanned using a Micro-CT. The obtained structural geometries were meshed with linear, eight-noded hexahedral elements. The mechanical behavior (deformation and von Mises equivalent stress) of the three endodontic instruments were analyzed under four bending and rotational conditions using ABAQUS finite element analysis software. The nonlinear mechanical behavior of the NiTi was taken into account. The U-shaped cross sectional geometry of ProFile showed the highest flexibility of the three file models. The ProTaper, which has a convex triangular cross-section, was the most stiff file model. For the same deflection, the ProTaper required more force to reach the same deflection as the other models, and needed more torque than other models for the same amount of rotation. The highest von Mises stress value was found at the groove area in the cross-section of the ProTaper Universal. Under torsion, all files showed highest stresses at their groove area. The ProFile showed highest von Mises stress value under the same torsional moment while the ProTaper Universal showed the highest value under same rotational angle.

Comparison of shaping ability using LightSpeed, ProTaper and Hybrid technique in simulated root canals (모조 레진블락 근관에서 LightSpeed, ProTaper 및 Hybrid technique의 성형 효율 비교)

  • Kang, Soon-Il;Kwak, Sang-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.47 no.7
    • /
    • pp.444-454
    • /
    • 2009
  • The purpose of this study was to compare the shaping abilities of LightSpeed, ProTaper-Universal, and hybrid technique using S-series of ProTaper-Universal and LigthSpeed. The 72 simulated root canals of J-shape were used and classified as flowing 3 groups according to the instrumentation methods; Group P of 24 canal blocks were prepared with ProTaper-Universal, Group L was prepared with LightSpeed, and Group H was prepared with hybrid technique (initial shaping with ProTaper-Universal SI and S2 and apical shaping with LightSpeed from #25 to #50). A second-year resident of Endodontic department prepared the resin block canals to apical size #50 (F5 in Group P). The time lapses for instrumentation and the reduction of root canal curvature after shaping were measured. The pre- and post-instrumented root canals were scanned and superimposed to evaluate and calculate the increased canal width and apical centering ratio. The results were as followings: Group Land H showed significant less instrumentation time than Group P (p < 0.05). The ProTaper system showed greater reduction of root canal curvature and working length diminishment than other methods (p < 0.05). LightSpeed system showed best canal curvature preserving characteristics. The Group P had greater instrumented widths at all levels examined (p < 0.05). Group L and Group H showed lower centering ratio (ability to preserve the canal center; the lower ratio means the better canal center preservation) than Group P (p < 0.05). Group H had the lowest centering ratio at the 1 mm level.

  • PDF

Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatment

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.34-38
    • /
    • 2017
  • Objectives: The aim of this study was to evaluate the cyclic fatigue resistance of the ProTaper Universal D1 file (Dentsply Maillefer) under continuous and adaptive motion. Materials and Methods: Forty ProTaper Universal D1 files were included in this study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which had an artificial stainless steel canal with a $60^{\circ}$ angle of curvature and a 5 mm radius of curvature. The files were randomly divided into two groups (Group 1, Rotary motion; Group 2, Adaptive motion). The time to failure of the files were recorded in seconds. The number of cycles to failure (NCF) was calculated for each group. The data were statistically analyzed using Student's t-test. The statistical significant level was set at p < 0.05. Results: The cyclic fatigue resistance of the adaptive motion group was significantly higher than the rotary motion group (p < 0.05). Conclusion: Within the limitations of the present study, the 'Adaptive motion' significantly increased the resistance of the ProTaper Universal D1 file to cyclic facture.

Shaping ability and apical debris extrusion after root canal preparation with rotary or reciprocating instruments: a micro-CT study

  • Emmanuel Joao Nogueira Leal da Silva;Sara Gomes de Moura;Carolina Oliveira de Lima;Ana Flavia Almeida Barbosa;Waleska Florentino Misael;Mariane Floriano Lopes Santos Lacerda;Luciana Moura Sassone
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.16.1-16.11
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the shaping ability of the TruShape and Reciproc Blue systems and the apical extrusion of debris after root canal instrumentation. The ProTaper Universal system was used as a reference for comparison. Materials and Methods: Thirty-three mandibular premolars with a single canal were scanned using micro-computed tomography and were matched into 3 groups (n = 11) according to the instrumentation system: TruShape, Reciproc Blue and ProTaper Universal. The teeth were accessed and mounted in an apparatus with agarose gel, which simulated apical resistance provided by the periapical tissue and enabled the collection of apically extruded debris. During root canal preparation, 2.5% sodium hypochlorite was used as an irrigant. The samples were scanned again after instrumentation. The percentage of unprepared area, removed dentin, and volume of apically extruded debris were analyzed. The data were analyzed using 1-way analysis of variance and the Tukey test for multiple comparisons at a 5% significance level. Results: No significant differences in the percentage of unprepared area were observed among the systems (p > 0.05). ProTaper Universal presented a higher percentage of dentin removal than the TruShape and Reciproc Blue systems (p < 0.05). The systems produced similar volumes of apically extruded debris (p > 0.05). Conclusions: All systems caused apically extruded debris, without any significant differences among them. TruShape, Reciproc Blue, and ProTaper Universal presented similar percentages of unprepared area after root canal instrumentation; however, ProTaper Universal was associated with higher dentin removal than the other systems.

Root canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals

  • Park, Hyun-Jin;Seo, Min-Seock;Moon, Young-Mi
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.3.1-3.10
    • /
    • 2018
  • Objectives: The aim of this study was to compare root canal volume change and canal transportation by Vortex Blue (VB; Dentsply Tulsa Dental Specialties), ProTaper Next (PTN; Dentsply Maillefer), and ProTaper Universal (PTU; Dentsply Maillefer) nickel-titanium rotary files in curved root canals. Materials and Methods: Thirty canals with $20^{\circ}-45^{\circ}$ of curvature from extracted human molars were used. Root canal instrumentation was performed with VB, PTN, and PTU files up to #30.06, X3, and F3, respectively. Changes in root canal volume before and after the instrumentation, and the amount and direction of canal transportation at 1, 3, and 5 mm from the root apex were measured by using micro-computed tomography. Data of canal volume change were statistically analyzed using one-way analysis of variance and Tukey test, while data of amount and direction of transportation were analyzed using Kruskal-Wallis and Mann-Whitney U test. Results: There were no significant differences among 3 groups in terms of canal volume change (p > 0.05). For the amount of transportation, PTN showed significantly less transportation than PTU at 3 mm level (p = 0.005). VB files showed no significant difference in canal transportation at all 3 levels with either PTN or PTU files. Also, VB files showed unique inward transportation tendency in the apical area. Conclusions: Other than PTN produced less amount of transportation than PTU at 3 mm level, all 3 file systems showed similar level of canal volume change and transportation, and VB file system could prepare the curved canals without significant shaping errors.

Cyclic fatigue, bending resistance, and surface roughness of ProTaper Gold and EdgeEvolve files in canals with single- and double-curvature

  • Khalil, Wafaa A.;Natto, Zuhair S.
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.2
    • /
    • pp.19.1-19.9
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate the cyclic fatigue, bending resistance, and surface roughness of EdgeEvolve (EdgeEndo) and ProTaper Gold (Dentsply Tulsa Dental Specialties) nickel-titanium (NiTi) rotary files. Materials and Methods: The instruments (n = 15/each) were tested for cyclic fatigue in single- ($60^{\circ}$ curvature, 5-mm radius) and double-curved (coronal curvature $60^{\circ}$, 5-mm radius, and apical curvature of $30^{\circ}$ and 2-mm radius) artificial canals. The number of cycles to fracture was calculated. The bending resistance of both files were tested using a universal testing machine where the files were bent until reach $45^{\circ}$. Scanning electron microscopy and x-ray energy-dispersive spectrometric analysis were used for imaging the fractured segments, while the atomic force microscope was used to quantify the surface roughness average (Ra). Results: EdgeEvolve files exhibited higher cyclic fatigue resistance than ProTaper Gold files in single- and double-curved canals (p < 0.05) and both files were more resistant to cyclic fatigue in single-curved canals than double-curved canals (p < 0.05). EdgeEvolve files exhibited significantly more flexibility than did ProTaper Gold files (p < 0.05). Both files had approximately similar Ni and Ti contents (p > 0.05). EdgeEvolve files showed significantly lower Ra values than ProTaper Gold files (p < 0.05). Conclusions: Within the limitation of this study, EdgeEvolve files exhibited significantly higher cyclic fatigue resistance than ProTaper Gold files in both single- and double-curved canals.

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.

Screw-in forces during instrumentation by various file systems

  • Ha, Jung-Hong;Kwak, Sang Won;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.4
    • /
    • pp.304-309
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Materials and Methods: Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS-k, DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Results: Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest (p < 0.05). Conclusions: Geometrical differences rather than shaping motion and alloys may affect the screw-in force during canal instrumentation. To reduce screw-in forces, the use of NiTi files with smaller cross-sectional area for higher flexibility is recommended.