단일 통풍형과 이중 통풍형 인공습지시스템의 하수처리 효율 비교

Comparison of Removal Efficiencies in Single and Duplex Ventilation Constructed Wetland Systems for Treating Domestic Sewage

  • 서동철 (루이지애나주립대 해양연안과학과) ;
  • 임석천 (경상대학교 응용생명과학부) ;
  • 조인성 (경상대학교 응용생명과학부) ;
  • 이병주 (경상대학교 응용생명과학부) ;
  • 이홍재 (진주산업대학교 환경공학과) ;
  • 김상돈 (국립환경과학원 영산강물환경연구소) ;
  • 이준배 (국립환경과학원 영산강물환경연구소) ;
  • 조주식 (순천대학교 생명환경과학부) ;
  • 허종수 (경상대학교 응용생명과학부)
  • Seo, Dong-Cheol (Department of Oceanography and Coastal Sciences, Louisiana State University) ;
  • Lim, Seok-Cheon (Division of Applied Life Science, Gyeongsang National University) ;
  • Jo, In-Seong (Division of Applied Life Science, Gyeongsang National University) ;
  • Lee, Byeong-Ju (Division of Applied Life Science, Gyeongsang National University) ;
  • Lee, Hong-Jae (Department of Environmental Engineering, Jinju National University) ;
  • Kim, Sang-Don (Yeongsan River Environmental Research Center, National Institute of Environmental Research Ministry of Environment) ;
  • Lee, Jun-Bae (Yeongsan River Environmental Research Center, National Institute of Environmental Research Ministry of Environment) ;
  • Cho, Ju-Sik (Division of Applied Life and Environmental Sciences, Sunchon National University) ;
  • Heo, Jong-Soo (Division of Applied Life Science, Gyeongsang National University)
  • 발행 : 2009.09.30

초록

농어촌 등에서 소규모로 발생하는 하수처리를 위한 환경 친화형 자연정화공법인 인공습지 하수처리장 개발을 위하여 수직흐름조(VF)-수평흐름조(HF) 인공습지 시스템을 수직흐름조는 현행 단일 통풍 구조에서 이중 통풍 구조로, 수평흐름조는 깊이를 현행 1.0 m에서 1.3 m로 하여 체적은 같으면서 표면적을 줄여 시공한 다음, 수직흐름조 통풍방법별, 수평흐름조 깊이별 및 하수부하량에 따른 수처리 효율을 조사하였다. 수직흐름조 통풍 방법에 따른 수처리 효율을 조사한 결과 BOD 및 COD는 이중 통풍형 구조가 단일 통풍형 구조에 비해 높은 처리효율을 보였다. 하지만 총 질소와 총 인은 두통풍형 구조 모두 큰 차이 없이 유사한 결과를 보였다. 따라서 수직흐름조의 최적 통풍방법은 이중통풍형 구조이었다. 수평흐름조 깊이에 따른 수처리 효율을 조사한 결과 BOD, COD, 총 질소 및 총 인 함량은 수평흐름조 깊이에 따라 별차이가 없었지만, 수평흐름조 깊이 1.3 m의 경우 인공습지 하수처리장의 시공시 부지면적을 감소시킬 수 있을 것으로 판단되므로 깊이 1.0 m에 비해 경제성과 유지관리면에서 바람직할 것으로 생각된다. 따라서 수평흐름조의 최적 깊이는 1.3 m이었다. 농어촌 지역에서 소규모로 발생하는 하수의 하수부하 변동에 대한 대응성을 조사하기 위하여 하수부하량에 따른 수처리 효율을 조사한 결과 BOD처리율은 하수부하량이 적을수록 약간 높았으며, COD 및 SS는 하수부하량에 따라서 별 차이가 없었고, 동일한 하수부하량에서는 이중 통풍형 공법이 대조구인 단일 통풍형 공법에 비해 높은 처리효율을 보였다. 총 질소 및 총 인 처리효율도 하수부하량이 증가함에 따라 처리효율이 점점 감소되는 경향이었고, 동일한 부하량에서는 이중 통풍형 공법이 단일 통풍형 공법에 비해 처리율이 약간 높았다. 따라서 하수처리장 공법별 및 하수부하량에서의 하수처리효율과 경제성 및 유지 관리비를 고려해볼 때 농어촌 등에서 소규모로 발생하는 하수를 효과적으로 처리하기 위한 인공습지 하수처리장은 수직흐름조 통풍방법이 이중 통풍형 구조이며 수평흐름조의 깊이가 1.3 m인 이중 통풍형 공법이 되어야 할 것으로 판단된다.

To develop environmentally friendly constructed wetlands(CWs) for treating domestic sewage which was produced in farming and fishing village, the efficiency of water treatment at different ventilation systems in the vertical bed, depths of horizontal bed, and sewage loads was investigated. In the vertical bed, BOD and COD by duplex ventilation system were lower than those by single ventilation system. But T-N and T-P concentrations by both ventilation systems in the vertical bed were little different. In the horizontal bed, BOD, COD, T-N and T-P in 1.0 m and 1.3 m depths were little different. To reduce the CWs' area and to improve the pollutant removal efficiencies, the optimum depth of horizontal bed was 1.3 m. In single and duplex ventilation CWs, the removal rate of BOD, COD, SS, T-N and T-P decreased slightly with the sewage load increases. In same sewage load conditions, the removal rates of BOD, COD, SS, T-N and T-P by duplex ventilation CWs were higher than those by single ventilation CWs. In summary, to effectively treat domestic sewage from farming and fishing village, the optimum constructed wetlands would be the duplex ventilation CWs.

키워드

참고문헌

  1. Kwun, S. K. and Yoon, C. G. (1999) Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas. Kor. J. Environ. Agric. 18(4), 310-315
  2. Park, M. R. (2005) Development of sewage treatment apparatus for detached house in agricultural village by natural purification method. Master Thesis. Gyeongsang National University of Education, Korea
  3. Kim, H. J. (2008) Development of natural purification technology for sewage treatment of a detached house in agricultural village. Master Thesis. Gyeongsang National University of Education, Korea
  4. Seo, D. C., Lee, H. J., Cho, J. S., Park, H. G., Kim, H. K. and Heo, J. S. (2003) Selection of optimum pebbles size in sewage treatment plant by natural purification method. Kor. J. Environ. Agric. 26(1), 26-35
  5. Chung, D. Y. (1999) Development of an environmentally friendly sewage disposal model for agricultural and fishing village areas. J. Korea Env Res & Reveg. Tech. 2(1), 10-20
  6. Seo, D. C., Park, W. Y., Lim, J. S., Park, C. H., Lee, H. J., Kim, H. C., Lee, S. W., Lee, D. J., Cho, J. S. and Heo, J. S. (2008) A Study on the improvement of treatment efficiency for nitrogen and phosphorus by improved sewage treatment process in constructed wetland by natural purification method. Kor. J. Environ. Agric. 27(1), 27-34 https://doi.org/10.5338/KJEA.2008.27.1.027
  7. Lim, S. C. (2003) Efficiency of Sewage Treatment by Improvement of Water Treatment System in Environmentally Friendly Constructed Wetland. Master Thesis. Gyeongsang National University of Education, Korea
  8. Kim, J. T., Moon, K. H. and Kim, J. W. (2001) The standard method of water analysis. Shinkwang a publishing company (in Korea)
  9. APHA, AWWA, WCF. (2005) Standard methods for the examination of water and wastewater, 17th Edition. American Public Health Association, Washington, DC
  10. Seo, D. C. (2002) Development of sewage treatment apparatus by natural purification method. Master Thesis. Gyeongsang National University of Education, Korea
  11. Seo, D. C. (2005) Development of treatment process of biological nitrogen and phosphorus in sewage treatment plant by natural purification system. Doctor Thesis. Gyeongsang National University of Education, Korea
  12. Corbitt, R. A. and Bowen, P. T. (1994) Constructed wetlands for wastewater treatment, in Applied Wetlands science and technology, Kent, D. M. (ed.), Publishers Lewis, 221-241
  13. Seo, D. C., Cho, J. S., Lee, H. J. and Heo, J. S. (2005) Phosphorus retention capacity of filter media for estimating the longevity of constructed wetland. Wat. Res. 39, 2445-2457 https://doi.org/10.1016/j.watres.2005.04.032
  14. Korean Ministry of Environment (2006) Environmental White Book of 2006. Ministry of Environment Republic, Seoul (in Korea)
  15. Yoon, C. K., Kwun, S. K., Woo, S. H. and Kwun, T. Y. (1999) Review of 3 - year experimental data from treatment wetland for water quality improvement in rural area. J. Korean Soc. Environ. Eng. 15(4), 581-589

피인용 문헌

  1. Long-term performance of vertical-flow and horizontal-flow constructed wetlands as affected by season, N load, and operating stage for treating nitrogen from domestic sewage vol.23, pp.2, 2016, https://doi.org/10.1007/s11356-015-5214-z