• Title/Summary/Keyword: Vertical bed

Search Result 208, Processing Time 0.023 seconds

A Study on the Modal Analysis of Hybrid Vertical Grinding System Bed (수직형 복합 연삭시스템 베드의 동특성 해석에 관한 연구)

  • Choi, Seung-Geon;Kim, Seong-Hyun;Choi, Woong-Kirl;Shin, Hyun-Jung;Lee, Eun-Sang;Kim, Kyu-Dong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.50-56
    • /
    • 2013
  • Machine tools are the cores of industrial development in recent period. It is difficult to develop a system which can do cutting and grinding process in the one system. Hybrid Vertical Grinding System is capable of processing in a single apparatus cutting or grinding. The modal analysis and structural analysis for the development of Hybrid Vertical Grinding System is the first time of domestic work. In this study, Hybrid Vertical Grinding System bed was designed and analyzed by using SS401 and FC300 as materials. And by using Finite Element Methods, the design and material of the bed was analysed. Finally, we can make a better choice of structure and material of the bed by comparing the analysis results.

Vertical Flow Zeolite-Filled Reed Bed for Treatment of Artificial Sewage with Intermittent Feeding (수직 흐름 제올라이트 갈대 여과상의 간헐적 주입에 의한 인공하수 처리)

  • 서정윤;김태형;최민수
    • KSBB Journal
    • /
    • v.18 no.2
    • /
    • pp.140-144
    • /
    • 2003
  • The artificial sewage was treated using a vertical flow zeolite-filled reed bed. The artificial sewage was fec into the reed bed for 10 minutes every 6 hours at the hydraulic load 314 L/$m^2$ \ulcorner day. The filtering height of the reed bed was 100 cm and the zeolite mixture was filled in the reed bed. The mixture consisted of the same volume of two types of zeolites ; 0.5~1 mm and 1~3 mm in diameter. Annual average removal efficiency was CO$D_{Cr}$ 95.1%, T-N 49.5%, $NH{_4^+}$-N 99.4% and T-9 56.4%. T-N removal efficiency decreaced remarkably from 73 to 27% with the operating time. Most of T-P was adsorbed in the uper area of the reed bed. The major portion of adsorbed phosphorus was composed of Fe-, Ca- and reductant selubele Fe-P.

Vertical Distribution of Tiger Worm (Oligochaeta : Eisenia fetida) Population in the Rearing Bed (지렁이 사육상에서 줄지렁이(Eisenia fetida) 개체군의 수직분포)

  • Park, Kwang-Il;Kim, Byung-Woo;Bae, Yoon-Hwan
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.4
    • /
    • pp.93-99
    • /
    • 2007
  • Vertical distribution of tiger worm(Eisenia fetida) population in the earthworm rearing bed was investigated with feeding paper mill sludge. More than 50% of larva and adult population of Eisenia fetida lived within the depth of 5 cm from the surface of rearing bed. And more than 96% of the population of larva, adult and cocoon lived within the depth of 20 cm. Percental vertical distribution of Eisenia fetida population in the rearing bed was not much influenced by the changes in the height of rearing bed or density of earthworm population.

  • PDF

Numerical analysis of fluid flow and thermal fields in the vertical fluidized bed heat exchanger (수직형 순환유동층 열교환기에서의 유체유동과 온도장의 수치해석)

  • Lee, B.C.;Kang, H.K.;Lee, M.S.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.16 no.4
    • /
    • pp.24-29
    • /
    • 2012
  • The numerical analysis by using CFX 11.0 commercial code was done for prediction of fluid flow and thermal field in the vertical heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the fluid flow and temperatures in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which the solid particles of glasses (3 $mm{\Phi}$) were used in the fluidized bed with a smooth tube. The effect of circulation on the distance(L) of tube inlet and baffle plate was also examined. The present experimental and numerical results showed that the particles in the distance (Ds) of 15 mm showed a more efficient circulation without stacked the space and the LMTD(Log Mean Temperature Difference) in the fluidized bed type was much lower than that in the typical type shell and tube heat exchanger.

Community Structure and Vertical Distribution of Macrobenthos in the Mussel Bed on the Goijeong Rocky Shore in Jinhae (진해 괴정 암반 조간대 담치대의 대형저서동물 군집구조 및 수직분포)

  • PAIK Sang-Gyu;YUN Sung Gyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.5
    • /
    • pp.500-508
    • /
    • 2003
  • The fauna associated with mussel (Mytilus galloprovincialis) beds and vertical distribution of macrobenthos were studied on the Goijeong rocky shore in Jinhae Bay, Korea. Sampling was conducted seasonally using a quadrate from January to October, 1998. In the first experiment, to reveal the community structure of macrobenthos in mussel bed, a total of 62 species $(10,690ind./m^2,\;3,802.1\;g/m^2)$ were identified, which included polychaetes $(32\;spp.,\;52.6\%),$ molluscs (16 spp.), crustaceans (10 spp.), and others. The density-dominant species were Pseudopolydora antennata, Nereis heterocirrata, Littorina brevicula and Balanus kondakovi. And the density of associated fauna was correlated with that of mussel (r=0.951, p=0.049). In the second experiment, to reveal the vertical distribution of macrobenthos on the rocky shore, ANOVA showed highly significant differences between the density of top 5 dominant species (Chthamalus challengeri, Littorina brevicula, Balanus kondakovi, Septifer virgatus and Granulilittorina exigua) and tidal levels (P=0.000). Vertical distribution of macrobnethos was characterized by Ghthamalus belt and Balanus-Septifer belt in the mussel bed.

Performance Analysis of Moving Bed Heat Exchanger of Solid Particles in a Vertical Pipe (고체입자 이동층을 이용한 수직 전열관 열교환기의 성능해석)

  • Park, Sang-Il;Choe, Gyeong-Bin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.2916-2923
    • /
    • 1996
  • A numerical analysis of the moving bed heat exchanger of solid particles inside the vertical pipe was performed using finite difference method. Also, the theoretical solutions were obtained for comparison when the wall heat flux or the wall temperature was assumed constant. The comparison showed that their results agreed well each other. The moving bed heat exchanger was classified as countercurrent-flow, parallel-flow, and cross-flow types according to the gas flow direction. For each type, the thermal efficiency of heat exchanger was calculated as a function of non-dimensional parameters such as the characteristic length of heat exchanger, Biot number and the ratio of thermal capacities of gas and solid particles.

Development of a Particle Bed Heat Exchanger(II) -An Experimental Study on Heat Transfer Characteristics of Fluidized Bed Heat Exchanger with Double Pipe (Parallelflow) (입자층(粒子層)을 이용(利用)한 열교환기(熱交換器) 개발(開發)에 관(關)한 연구(硏究)(II) - 유동층형(流動層形) 이중관식(二重管式) 열교환기(熱交換器)의 전열특성(傳熱特性)에 대한 실험적(實驗的) 연구(硏究)(병행류식(竝行流式)))

  • Kim, G.C.;Yoo, J.O.;Yang, H.J.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.2
    • /
    • pp.127-136
    • /
    • 1990
  • Air-solid bed has been known to be an effective heat transfer augmentation device which could be applied to heat exchangers. In this study, pressure drop and heat transfer characteristics of vertical annular fluidized bed heat exchanger with air flowing through were studied experimentally. The experiments was conducted to calculate overall heat transfer coefficient on fluidized bed heat exchangers immersed single vertical tube and investigate minimum fluidized velocity in fluidized bed of alumina beads and steel balls. The influence of flow direction, particle diameter, the heights of static bed and air mass fluidizing velocity has been examined. The experimental results showed the optimum operating condition and effective static bed height for fluidized bed heat exchangers. For the same power loss, comparisions of heat transfer effect between the fluidized bed heat exchanger and the single phase forced convetion heat exchanger indicate that both miniaturization of heat exchanger and heat transfer augmentation at low flow velocity are possible by application of the air-solid to heat exchangers.

  • PDF

PORE PRESSURE AND EFFECTIVE STRESS IN THE SATURATED SAND-BED UNDER THE VARIATION OF WATER PRESSURE

  • HoWoongShon
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.2
    • /
    • pp.107-119
    • /
    • 2003
  • The behavior of pore pressure and effective stress in a highly saturated sand bed under variations in the water pressure in its surface were investigated to determine the mechanism of the collapse of hydraulic structures during flooding or when attacked by storm waves. The vertical, one-dimensional model was used as a basic model to clarify the effect of water pressure variation on only to the vertical direction. The theoretical results show that a sand bed under variations of water pressure is weakened by an increase in excess pore pressure and that under certain conditions the sand bed will liquefy. Although many factors related to water pressure variation and property of the material determine this phenomenon, the mist important factor seems to be the small amount of air present in the sand bed. The theoretical results reported are verified by experiments.

  • PDF

Heat Transfer in the Vertical Type Fluidized Bed Heat Exchanger with Corrugated Tubes (파형관을 갖는 수직형 순환유동층 열교환기의 열전달)

  • Ahn Soo Whan;Bae Sung Taek;Kim Myung Ho;Lee Byung-Chang;Lee Yoon Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1149-1155
    • /
    • 2004
  • An experimental study was performed to investigate the characteristics of heat transfer in a vertical type fluidized bed shell-and-tube type heat exchanger with corrugated tube. Seven different solid particles having the same volume were circulated in the heat of exchanger. The effects of various parameters such as water flow rates, particle geometries, materials, and corrugated tube geometries were investigated. The present work showed that the higher thermal capacities of materials and the geometries closer to the spherical one have higher heat transfer performances. In addition, heat transfer coefficients in the corrugated tubes were a little higher than those in the smooth tubes.

Stress analysis according to the vertical bone level in the implant placement (임플란트 매식 시 수직골 높이에 따른 응력분석)

  • Kim, Min-Ho;Park, Young-Rok;Kay, Kee-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.301-311
    • /
    • 2002
  • The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different vertical bone level of implant fixture. The two kinds of finite element models were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$). The cemented crowns for mandibular first and second molars were made. Three- dimensional finite element model was created with the components of the implant and surrounding bone. Vertical loads were applied with force of 200N distributed within 0.5mm radius circle from the center of central fossa and distance 2mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the supporting bone, fixtures, abutment screws, and crown. The results were as following : (1) In vertical loading at the center circle of central fossa on model 1 and 2, the difference from vertical bone in implant placement did not affect the stress pattern on all components of implant except for crown. (2) With offset distance incerasing and the bone level of implant decreasing, the concentration of stress occured in the buccal side of long crown, around the buccal crestal bone, and on the fixture- abutment interface. As a conclusion, the research showed a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the vertical level of bone around fixture was different. Since the same vertical bone bed has more benefits than the different bone bed around fixtures, it is important to prepare a same vertical level of bone bed for the success of implants under occlusal loads.