DOI QR코드

DOI QR Code

A Fatigue Stability Study of an Existing Bridge Due to Vehicle Load Direction Change

차량 하중 방향 변경에 의한 기존교량의 피로안정성 연구

  • Yi, Gyu-Sei (Department of Civil Engineering, Sunmoon University) ;
  • Lee, Sung-Yol (Department of Civil Engineering, Sunmoon University)
  • Published : 2009.08.31

Abstract

During a construction of a road, a temporary bridge is often connected to a existing bridge. In this case, a fatigue stability problem, which was not considered in the design of the bridge, can be occurred in the main girder of the existing bridge due to the vehicle load direction change. In this study, the fatigue stability of the main girder and cantilever slab of the bridge was tested with the allowable fatigue stress of the design specifications of the road bridge. The big stress change was occurred at 55m away from the support, and the middle of the span. Furthermore, the excess of the allowable fatigue stress of the design specifications of the road bridge was confirmed at the cross section. The bridge after the reinforcement was tested for the fatigue stability, and it was confirmed that the bridge is safe.

도로 건설 중 기존 교량에 가교를 접속하여 사용하는 경우가 종종 발생한다. 이 경우 차량 하중 방향의 변경으로 인하여 기존 교량의 주형의 설계 시 고려하지 못한 피로 안정성 문제가 발생할 수 있다. 따라서 본 연구에서는 기존 교량의 내민 슬라브와 주형의 안정성을 도로교 설계기준의 허용 피로 응력을 이용하여 검토하였다. 응력변동이 가장 큰 지점은 가교 접속 구간의 교량 시점에서 55m 떨어진 지점부, 그리고 교량 시점과 지점부 사이의 중앙점(교량 시점에서 32.5m 떨어진 지점)의 응력 변동이 크다는 것을 알 수 있었다. 이에 대한 기존 교량의 내민 슬라브와 주형에 보강이 필요함을 확인하여 보강대책을 수립하였고 보강 후 가교와 기존 교량의 피로 안정성 검토를 다시 수행하여, 도로교 설계 기준의 허용 피로 응력에 만족함을 확인하였다.

Keywords

References

  1. 도로교 설계 기준 사단법인 한국도로교통협회, 2005.
  2. 강영종, 김승준, 한택희, 최현수 "국내외 강구조물의 피로설계기준에 관한 연구" 한국강구조학회 학술발표논문집, 2007.
  3. 제 19회 MIDAS 기술세미나 '강상판형교의 반복하중에 의한 피로해석, 2008.
  4. 신동구, 권태형 박영석 "통행차량 특성을 반영한 강교량 피로설계트럭의 피로파괴 신뢰도 해석" 한국강구조학회 논문집, 2007.