고 선량율 감마선 조사에 따른 렌즈의 열화

A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation

  • 발행 : 2009.07.01

초록

Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

키워드

참고문헌

  1. J.Sejvar, 'Normal Operating Radiation Levels In Pressurized Water Reactor Plants', Nuclear Technology, Vol.36, p48-55, Nov.1977 https://doi.org/10.13182/NT77-A31957
  2. 'Comparison of Radiation Susceptibility for Microcircuits of Different Technologies', MIL-HDBK-978-B
  3. John V. Draper, Reid L. Kress and Barry L. Burks, 'Remote Maintenance Design Guide for Compact Processing Units', ORNL/TM-2000/124, 2000
  4. R.H. Jabs and D.E. Rygg, 'Extending Qualified Life of Class IE Equipment', IEEE Trans. on Energy Conversion, Vol. 4, No.2, June 1989, 211-215 https://doi.org/10.1109/60.17914
  5. Weed Instrument, 'DTN 2010 Pressure Transmitter', Product Data Sheet
  6. Rosemount, '1152 Alphaline${\circledR}$ Nuclear Pressure Transmitter', Product Data Sheet, 00813-0100-4235 Rev BA, 2007
  7. Weed Instrument, 'N4000R-99 Series RTD Temperature Transmitter Nuclear Qualified', Product Data Sheet
  8. C. Choi, Y.K. Choiu and C.C. Park, ' The Color Retrieval System with Color Component Analysis', International Workshop on Image Systems and Techniques, pp 35-39, 2004A https://doi.org/10.1109/IST.2004.1397277
  9. Ghosh, S. Devadas, K. Keutzer and J. White, 'Estimation of Average Switching Activity in Combinational and Sequential Circuits,' ACM/IEE Design Automation Conf., pp. 253-259, 1992. https://doi.org/10.1109/DAC.1992.227826