DOI QR코드

DOI QR Code

Steel Probing in Concrete Using Steel Corrosion Surface Measurement Method Modeling

철근부식 표면측정법 모델링을 통한 콘크리트 내 철근 탐사

  • Rhim, Hong-Chul (Dept. of Architectural Engineering, Yonsei University) ;
  • Ma, Hyang-Hwa (Industrial Plant Overseas Business Team, Samsung Engineering) ;
  • Lee, Suk-Yong (Dept. of Architectural Engineering, Yonsei University) ;
  • Lee, Kun-Woo (Dept. of Architecture, Kyungbok College) ;
  • Oh, Jin-Won (Dept. of Architectural Engineering, Yonsei University)
  • 임홍철 (연세대학교 건축공학과) ;
  • 마향화 (삼성엔지니어링 산업해외사업팀) ;
  • 이석용 (연세대학교 건축공학과) ;
  • 이근우 (경복대학 건축과) ;
  • 오진원 (연세대학교 건축공학과)
  • Published : 2009.04.30

Abstract

Using non-invasive surface measurement method, the corrosion state of steel embedded inside concrete can be measured by placing four electrodes on the surface of concrete. Modeling of such measurements can provide valuable information as how interfacial impedance between corroded steel and surrounding concrete results in measured impedance on the concrete surface. In this paper, the modeling of surface measurement technique is used for the determination of the sensitivity of the measurements with respect to steel bar size embedded inside concrete and cover thickness. Modeling results indicated that steel bar sizes varied from D10 to D35 could be identified. Concrete cover thickness changes from 0.02 m to 0.1 m was also distinguished using the modeling scheme. The results confirm this modeling technique is capable of determining steel bar sizes and cover thickness, as well as simulating corrosion responses.

콘크리트 표면에 4개의 전극배열을 이용한 비파괴 표면측정법을 통하여 철근의 피복을 벗겨내지 않고도 콘크리트 내 철근의 부식상태 및 철근의 배치상태를 추정할 수 있다. 표면측정법 모델링은 부식된 철근과 주위 콘크리트사이의 계면 임피던스가 콘크리트 표면에서 측정된 임피던스와 어떤 관련이 있는지를 보여준다. 본 연구에서는 콘크리트에 매립된 철근 크기와 콘크리트 피복두께 등의 탐지를 위하여 철근부식 표면측정 모델링을 이용하였다. 모델링 결과 철근 크기가 D10에서 D35로 커짐에 따라 표면임피던스 변화가 나타났으며, 또한 콘크리트 피복두께가 0.02 m에서 0.1 m로 커짐에 따라 그 변화에 대한 영향이 표면측정 임피던스를 통해 나타났다. 그러므로 표면측정법 모델링을 통하여 콘크리트 내 철근부식반응을 시뮬레이션 할 수 있으며, 동시에 철근직경과 매입 깊이 등에 대한 정보도 얻을 수 있음 알 수 있다.

Keywords

References

  1. 오창희, 윤재환, 임서형, “콘크리트중의 철근부식에 관한 전기화학적 진단 방법에 관한 연구,” 대한건축학회논문집, 6권, 3호 1990, pp. 281-289.
  2. 강태혁, 조원일, 조병원, 주재백, 윤경석, “전기화학적 임피던스법에 의한 철근콘크리트의 부식연구,” Journal of Korean Ind. & Eng. Chemistry, Vol. 9, No. 6, 1998, pp. 907-913.
  3. Feliu, V., Gonzales, J. A., Andrade, C., and Feliu, S., “Equivalent Circuit for Modeling the Steel-Concrete Interface, I. Experimental Evidence and Theoretical Predictions,” Corrosion Science, Vol. 40, No. 6, 1998, pp. 975-993. https://doi.org/10.1016/S0010-938X(98)00036-5
  4. Monteiro, P. J. M., Morrison, F., and Frangos, W., “Nondestructive Measurement of Corrosion State of Reinforcing Steel in Concrete,” ACI Materials Journal Technical Paper, 1998, pp. 704-709.
  5. Zhang, J., Monteiro, P. J. M., and Morrison, F., “Noninvasive Surface Measurement of Corrosion Impedance of Reinforcing Bar in Concrete-Part 2: Forward Modeling,” ACI Materials Journal Technical Paper, Title No. 99-M24, 2002, pp. 242-249.
  6. Zhang, J., Monteiro, P. J. M., Morrison, F., and Mancio, M., “Noninvasive Surface Measurement of Corrosion Impedance of Reinforcing Bar in Concrete - Part 3: Effect of Geometry and Matrial Properties,” ACI Materials Journal, Vol. 101, No.4, 2004, pp. 273-280.
  7. 임홍철, 이형우, “철근부식 표면측정 모델링을 이용한 철근의 직경변화 탐지,” 대한건축학회 논문집, 21권, 5호, 2005, pp. 3-9.
  8. Wenner, F., “A Method of Measuring Earth Rsistivity,” Bull. of the Bureau of Standards, Vol. 12, No. 4, 1915, pp. 468-478.
  9. Practice for Conducting Potentiodynamic Oolarization Resistance Measurements, G 59, ASTM, 1997.
  10. Carino, N. J., “Nondestructive Techniques to Investigate Corrosion Status in Concrete Structures,” Journal of Performance of Constructed Facilities, 1999, pp. 96-106. https://doi.org/10.1061/(ASCE)0887-3828(1999)13:3(96)
  11. 조승호, 정란, “철근부식에 따른 철근콘크리트 부재의 부식량 측정기법에 관한 연구,” 대한건축학회 학술발표 논문집, 20권, 2호, 2000, pp. 225~228.
  12. Test Method for Field Measurement of Soil Rsistivity Using the Wennr Electrode Method, G 57, ASTM, 1997.