참고문헌
- Branemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410 https://doi.org/10.1016/S0022-3913(83)80101-2
- Rangert B, Jemt T, Jorneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989;4:241-7
- Binon P, Sutter F, Beaty K, Brunski J, Gulbransen H, Weiner R. The role of screws in implant systems. Int J Oral Maxillofac Implants 1994;9:48-63
- Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994;9:169-78
- Hemmings KW, Schmitt A, Zarb GA. Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report. Int J Oral Maxillofac Implants 1994;9:191-6
- Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990;64:185-94 https://doi.org/10.1016/0022-3913(90)90177-E
- Jemt T. Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report. Clin Oral Implants Res 1994;5:142-7 https://doi.org/10.1034/j.1600-0501.1994.050304.x
- Jemt T, Lekholm U. Implant treatment in edentulous maxillae: a 5-year follow-up report on patients with different degrees of jaw resorption. Int J Oral Maxillofac Implants 1995;10:303-11
- Jemt T, Laney WR, Harris D, Henry PJ, Krogh PH Jr, Polizzi G, Zarb GA, Herrmann I. Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants 1991;6:29-36
- Naert I, Quirynen M, van Steenberghe D, Darius P. A sixyear prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. J Prosthet Dent 1992;67:236-45 https://doi.org/10.1016/0022-3913(92)90461-I
- Bickford JH. An introduction to the design and behavior of bolted joints. New York: Marcel Deckker.; 1981. p.247-64
- Cibirka RM, Nelson SK, Lang BR, Rueggeberg FA. Examination of the implant-abutment interface after fatigue testing. J Prosthet Dent 2001;85:268-75 https://doi.org/10.1067/mpr.2001.114266
- Gratton DG, Aquilino SA, Stanford CM. Micromotion and dynamic fatigue properties of the dental implant-abutment interface. J Prosthet Dent 2001;85:47-52 https://doi.org/10.1067/mpr.2001.112796
- Haack JE, Sakaguchi RL, Sun T, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants 1995;10:529-36
- Faulkner MG, Wolfaardt JF, Chan A. Measuring abutment/implant joint integrity with the Periotest instrument. Int J Oral Maxillofac Implants 1999;14:681-8
- Gross M, Abramovich I, Weiss EI. Microleakage at the abutment-implant interface of osseointegrated implants: a comparative study. Int J Oral Maxillofac Implants 1999;14:94-100
- Yildirim M, Edelhoff D, Hanisch O, Spiekermann H. Ceramic abutments--a new era in achieving optimal esthetics in implant dentistry. Int J Periodontics Restorative Dent 2000;20:81-91
- Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999;20:1-25 https://doi.org/10.1016/S0142-9612(98)00010-6
- Heydecke G, Sierraalta M, Razzoog ME. Evolution and use of aluminum oxide single-tooth implant abutments: a short review and presentation of two cases. Int J Prosthodont 2002;15:488-93
- Andersson B, Taylor A, Lang BR, Scheller H, Sch?rer P, Sorensen JA, Tarnow D. Alumina ceramic implant abutments used for single-tooth replacement: a prospective 1-to 3-year multicenter study. Int J Prosthodont 2001;14:432-8
- Cho HW, Dong JK, Jin TH, Oh SC, Lee HH, Lee JW. A study on the fracture strength of implant-supported restorations using milled ceramic abutments and all-ceramic crowns. Int J Prosthodont 2002;15:9-13
- Andresson B. Implants for single-tooth replacement. A clinical and experimental study on the Branemark CeraOne system. Swed Dent J Suppl. 1995;108:1-41
- Yildirim M, Fischer H, Marx R, Edelhoff D. In vivo fracture resistance of implant-supported all-ceramic restorations. J Prosthet Dent 2003;90:325-31 https://doi.org/10.1016/S0022-3913(03)00514-6
- Shin HM, Jeong CM, Jeon YC, Jeong HC, Eom TG. Influence of tightening torque on implant-abutment screw joint stability. [MS dissertation.] Korea: Pusan National University; 2007
- Siamos G, Winkler S, Boberick KG. Relationship between implant preload and screw loosening on implant-supported prostheses. J Oral Implantol 2002;28:67-73 https://doi.org/10.1563/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2
- ISO/FDIS 14801 Dentistry - Fatigue test for endosseous dental implants, International Organization for Standardization, 2003(E)
- Wiskott HW, Nicholls JI, Belser UC. Stress fatigue: basic principles and prosthodontic implications. Int J Prosthodont 1995;8:105-16
- Prestipino V, Ingber A. Esthetic high-strength implant abutments. Part I. J Esthet Dent 1993;5:29-36 https://doi.org/10.1111/j.1708-8240.1993.tb00741.x
- Prestipino V, Ingber A. Esthetic high-strength implant abutments. Part II. J Esthet Dent 1993;5:63-8 https://doi.org/10.1111/j.1708-8240.1993.tb00750.x
- Prestipino V, Ingber A. All-ceramic implant abutments: esthetic indications. J Esthet Dent 1996;8:255-62 https://doi.org/10.1111/j.1708-8240.1996.tb00876.x
- Scherrer SS, Kelly JR, Quinn GD, Xu K. Fracture toughness (KIc) of a dental porcelain determined by fractographic analysis. Dent Mater 1999;15:342-8 https://doi.org/10.1016/S0109-5641(99)00055-X
- Glauser R, Sailer I, Wohlwend A, Studer S, Schibli M, Sche'rer P. Experimental zirconia abutments for implantsupported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. Int J Prosthodont 2004;17:285-90
- Gehrke P, Dhom G, Brunner J, Wolf D, Degidi M, Piattelli A. Zirconium implant abutments: fracture strength and influence of cyclic loading on retaining-screw loosening. Quintessence Int 2006;37:19-26
- Butz F, Heydecke G, Okutan M, Strub JR. Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation. J Oral Rehabil 2005;32:838-43 https://doi.org/10.1111/j.1365-2842.2005.01515.x
- Att W, Kurun S, Gerds T, Strub JR. Fracture resistance of single-tooth implant-supported all-ceramic restorations: an in vitro study. J Prosthet Dent 2006;95:111-6 https://doi.org/10.1016/j.prosdent.2005.12.003
- Korioth TW, Cardoso AC, Versluis A. Effect of washers on reverse torque displacement of dental implant gold retaining screws. J Prosthet Dent 1999;82:312-6 https://doi.org/10.1016/S0022-3913(99)70086-7
- Mcglumphy EA. Keeping implant screws tight : the solution. J Dent Symp. 1993 Aug;1:20-3
- Adrian ED, Krantz WA, Ivanhoe JR, Turner KA. A silicone obturator for the access canal in an implant-retained fixed prosthesis. J Prosthet Dent 1991;65:597 https://doi.org/10.1016/0022-3913(91)90306-H
- Kirkwood WF, Feng WW, Scott RG, Streit RD, Goldberg A. Mechanical properties and science of engineering materials. In: Blake A[ed]. Handbook of Mechanics, Materials, and Structures. London: Wiley, 1985:320-8
- Leempoel PJ, Van't Hof MA, de Haan AF. Survival studies of dental restorations: criteria, methods and analyses. J Oral Rehabil 1989;16:387-94 https://doi.org/10.1111/j.1365-2842.1989.tb01355.x
- Mericske-Stern R, Zarb GA. In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants. Clin Oral Implants Res 1996;7:153-61 https://doi.org/10.1034/j.1600-0501.1996.070209.x
- Richter EJ. In vivo vertical forces on implants. Int J Oral Maxillofac Implants 1995;10:99-108
- Carlsson GE, Haraldson T. Functional response in tissueintegrated prosthesis, 4th ed. Quintessence Publ, co, 1986:74-78
- Bates JF, Stafford GD, Harrison A. Masticatory function - a review of the literature. III. Masticatory performance and efficiency. J Oral Rehabil 1976;3:57-67 https://doi.org/10.1111/j.1365-2842.1976.tb00929.x
- Richter EJ. In vivo vertical forces on implants. Int J Oral Maxillofac Implants 1995;10:99-108
- Norton MR. Assessment of cold welding properties of the internal conical interface of two commercially available implant systems. J Prosthet Dent 1999;81:159-66 https://doi.org/10.1016/S0022-3913(99)70243-X
- Weiss EI, Kozak D, Gross MD. Effect of repeated closures on opening torque values in seven abutment-implant systems. J Prosthet Dent 2000;84:194-9 https://doi.org/10.1067/mpr.2000.108069
- Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9
- Merz BR, Hunenbart S, Belser UC. Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000;15:519-26
- Cibirka RM, Nelson SK, Lang BR, Rueggeberg FA. Examination of the implant-abutment interface after fatigue testing. J Prosthet Dent 2001;85:268-75 https://doi.org/10.1067/mpr.2001.114266
- Binon PP. Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs. Int J Prosthodont 1995;8:162-78
- Schwarz MS. Mechanical complications of dental implants. Clin Oral Implants Res 2000;11:156-8 https://doi.org/10.1034/j.1600-0501.2000.011S1156.x
- Binon PP. Implants and components: entering the new millennium. Int J Oral Maxillofac Implants 2000;15:76-94
- Leempoel PJ, Van't Hof MA, de Haan AF. Survival studies of dental restorations: criteria, methods and analyses. J Oral Rehabil 1989;16:387-94 https://doi.org/10.1111/j.1365-2842.1989.tb01355.x
- Sutter F, Weber HP, Sorensen J, Belser U. The new restorative concept of the ITI dental implant system: design and engineering. Int J Periodont Rest Dent 1993;13:409-31
- Balfour A, O'Brien GR. Comparative study of antirotational single tooth abutments. J Prosthet Dent 1995;73:36-43 https://doi.org/10.1016/S0022-3913(05)80270-7