Glass forming technology is used to form channels of external electrode flat fluorescent lamps (FFL). The efficiency of FFL depends on the number and the length of the channels. Five FFLs with same size ($300\;mm{\times}80\;mm$), different channel number, and different channel length were fabricated. The electrical and optical characteristics of 5 FFLs were evaluated. It was found that the FFL with one channel with its channel length of 1,110 mm and channel width of 7 mm corner width was shown to have the highest efficiency at room temperature operation.

키워드

참고문헌

  1. 김영미, 권남옥, 조광섭 "외부전극 형광램프 백라이트의 구형파 구동", 한국진공학회 Vol. 12, No. 1 pp. 46-50, 2003년.
  2. H. S. Kim, el al., SID Symposium Digest 32, pp. 687-689, 2001.
  3. Y. S. Kim, el al., SID Symposium Digest 37, pp. 500-502, 2006.
  4. 조현창, 임영철, 양승학, 박연도, "37인치 LCD TV용 백라이트 시스템에 관한 연구", 전력전자학회 추계학술대회 논문집, pp. 106-109, 2004.
  5. 윤창선, 조현창, 허동영, 김광헌, 임영철, "대화면 LCD TV를 위한 CCFL 백라이트 인버터에 관한 연구" 전력전자학회논문지 제11권 제6호, pp. 502-507, 2006.
  6. 권기현, 한재현, 임영철, 양승학, "대형 LCD 백라이트용 멀티램프 구동 인버터 설계", 전력전자학술대회 논문집, pp. 340-343, 2001.
  7. 전영태, 임성규, "LCD TV용 고균일도 백라이트 구동을 위한 Differential Driving 인버터", 한국마이크로전자 및 패키징학회 논문집, Vol. 11, No. 2. pp. 37-41, 2004.
  8. Jae-Hyeon Ko, CVCE2006 Conference, 2006.
  9. Takashi Nishihara, "Technical trend of light source & inverter for large size LCD TV", Harison Toshiba Lighting, Korea display Conference, 2004.
  10. J.W. Hur, the 6th IMID and the 5th IDMC Conference Digest, pp1725-1728, 2006.