전부주조관용 Ni-Cr 합금 재주조에 따른 변연의 적합도에 대한 연구
A study on the fitness of the margin to recast with a Ni-Cr alloy for full cast crown
- 문희경 (진주보건대학 치기공과)
- Moon, Hee-Kyung (Dept. of Dental laboratory Technology, Jin Ju Health College)
- 발행 : 2009.03.31
초록
This experimental study was to determine the fitness on each cervical margin of recast using crown base metal alloy. The alloy used in this experimental study was a Ni-Cr alloy(Wirolloy, Bego, Germany) for the fabrication of full cast crown prosthesis. Twenty-five copings were divided into the five groups. And the group A, B, C, D and E were cording successively according to the frequency of recast to five times. Each specimen was recasted without adding new metal. The experimental results were as follows: 1. The group A and B showed good fitness had subtle differences in each cervical margin adaptation, in other words, the mesio and disto cervical margin showed worse adaptation than the bucco and linguo cervical margin. 2. The group C got good fitness in bucco and linguo cervical margins, but the mesio and disto cervical margin showed inaccurate fitness. And I could not get good casting bodies without adding new metal. 3. The group D and E showed bad fitness for each cervical margin. Therefore the group D and E lost its function as a dental restoration.