Abstract
Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.
목 적: 전립선암 환자의 방사선 치료 시 전립선의 위치 변화 및 비뇨기계 부작용을 줄이기 위해 방광의 체적을 일정하게 유지하도록 한 후 초음파를 이용하여 방광의 체적 변화를 측정 하였다. 대상 및 방법: 2002년 12월부터 2007년 8월 까지 이대 목동병원에서 전립선 암으로 진단받고 근치적 목적의 방사선 치료를 받은 환자 26명을 대상으로 하였다. 13명의 실험군 환자는 방광의 체적을 일정하게 유지하기 위하여 모의조사, CT 스캔, 및 치료 1시간 전에 450 cc의 물을 마시도록 하였다. 나머지 13명의 대조군 환자에 대해서는 특별한 지시를 하지 않았다. 각 환자의 CT영상에서 방광의 체적을 측정하였다. 3차원 입체 조형 치료 계획이 설계되었고 처방선량 70.2 Gy 조사할 경우 방광과 직장의 유효체적을 계산 하였다. 실험군에 속해 있는 환자에 대해 방사선 치료 전 방광의 체적을 초음파를 이용하여 6-8주 간 매주 측정하였고 방광의 체적 변화를 분석하였다. 결과: CT상에서 측정 한 방광의 평균 체적 및 표준 오차는 실험군의 경우 $283.5{\pm}114.0\;cc$ (40%) 이고 대조군의 경우 $181.2{\pm}120.1\;cc$ (66%) 이다. 실험군의 경우 CT 상의 방광 체적과 CT scan 전에 획득한 초음파 영상상의 방광 체적은 통계적으로 유의하지 않으나 상관관계가 있는 것으로 보이고 초음파를 이용하여 측정한 방광의 체적은 CT상에서의 체적의 평균 62% 이다. 실험군에 있어서 초음파 시스템을 이용하여 주간 측정한 방광의 체적의 변화는 상당히 컸으며 최소 33%에서 최대 75%까지 변화 하였다. 결론: CT 스캔 전에 일정한 양의 물을 마시도록 지시한 실험군의 환자들의 경우 대조군대비 평균 방광의 체적을 크게 유지할 수 있었다. 그러나 일정한 양의 물을 마시도록 지시하더라도 6-8주간의 치료 기간 중에 방광의 체적을 일정히 유지 하는데는 어려움이 있었다.