Abstract
The objective of this study is to verify whether the composite action is sufficiently strong to withstand at the interface and the structural behavior of LB-DECK panel with field concrete slab strengthened with main reinforcing bars. Static and fatigue tests are performed for LB-DECK panels with varied shapes and amounts of rebars, and the results are compared with those of field concrete panel(FCP). The test results indicate that the LB-DECK panel with 1.5 times of more rebars inside significantly increase the overall stiffness. LB-DECK penel usually shows on average 52.1 percent of improved stiffness compared with the FCP. The fatigue test results also show that the LB-DECK panel can withstand two-million cycles of repeated loads without any damage.
본 연구는 최근 교량에 많이 이용되고 있는 프리캐스트 바닥판(LB-DECK) 패널과 후타설 현장콘크리트 슬래브의 합성거동 여부 및 내부에 매입된 하면 주철근의 합성 후 구조적 거동을 분석한 것이다. 이를 위하여 현장배근 주철근의 철근량 및 배근방법에 따라 LB-DECK 패널의 정적거동 실험을 하여 현장타설 콘크리트 패널(FCP)과 비교 분석하였으며, 반복하중에 대한 평가를 위하여 피로실험을 하였다. 실험 결과, LB-DECK 패널 주철근량의 50%를 LB-DECK 패널 내부에 추가 배근하였을 경우 가장 우수한 강성을 나타내었으며, LB-DECK 패널이 FCP에 비해 평균 52.1%의 강성 증가 효과가 있음을 알 수 있었다. 또한 LB-DECK 패널에 대한 피로 실험 결과 200만회 반복하중에서도 충분한 건전도를 유지함을 알 수 있었다.