Shaking Table Test of Isolated EDG Model

면진된 모형 비상디젤발전기의 지진응답 실험

  • 김민규 (한국원자력연구원 종합안전평가연구센터) ;
  • 전영선 (한국원자력연구원 종합안전평가연구센터)
  • Published : 2007.06.30

Abstract

In this study, for research on an improvement of the seismic safety of an EDG system, a small scale EDG system was manufactured. For the isolation system, the Coil Spring-Viscous Damper systems were selected. For the shaking table test, 3 kinds of seismic motions were selected which had different frequency contents. In this study, the isolation effects were different and they depended on the input seismic motion. In the case of an NRC earthquake which had low fiequency contents, the isolation effects of the horizontal direction were 20%. But for the seismic motions which had high fiequency contents, the isolation effects were $50{\sim}70%$. In the case of the vertical direction, poor isolation effects were observed. It was because the design properties and the real properties of the isolation system were a little different.

본 연구에서는 원전내 주요 안전관련 기기중 비상디젤발전기를 대상으로 한 진동대 실험을수행하였다. 원전의 비상디젤 발전기는 원전 전체의 노심손상빈도에 미치는 영향이 매우 크며 또한 면진장치를 설치하여 지진력을 저감시킬 경우 큰 폭으로 노심손상빈도를 감소시킬 수 있으며, 가동중 발생하는 소음과 진동으로 인하여 주변 구조물과 기기에 영향을 미치기도 한다. 따라서 지진력 저감과 기계 진동의 저감효과를 동시에 고려하기 위한 면진장치를 적용하여 그 효과를 평가하여 보고자하였다. 면진장치로는 코일스프링과 점성 댐퍼가 결합된 형태의 면진장치를 선정하였다. 실험의 대상으로 하는 비상디젤발전기는 영광 5,6호기에 설치되어 있는 모델로서 축소모형을 제작하였으며, 제작된 모형에 적합한 코일스프링-점성댐퍼 시스템을 설계하여 제작하였다. 제작된 면진장치를 축소모형에 설치하여 설계지진을 이용한 진동대 시험을 수행하여 지진력 저감효과를 분석하였다 본 연구를 통하여 설계지진의 경우 20% 그리고 Scenario 지진의 경우 70% 까지의 지진력 저감이 가능한 것을 확인하였으며, 면진장치의 기계적 특성이 설계값과 일치하지 않음으로 인하여 실제 지진력 저감효과가 크게 변할 수 있음을 확인할 수 있었다.

Keywords

References

  1. Ebisawa, K., Ando, K. and Shibata, K., 'Progress of a research program on seismic base isolation of nuclear components,' Nuclear Engineering and Design, 198(1-2), 2000, pp. 61-74 https://doi.org/10.1016/S0029-5493(99)00272-1
  2. GERB, Vibration Isolation Systems, 2000
  3. Makris, N. and Constantinou, M.C., 'Spring-Viscous Damper Systems for Combined Seismic and Vibration Isolation,' Earthquake engineering and Structural Dynamics, vol. 21, 1992, pp. 649-664 https://doi.org/10.1002/eqe.4290210801
  4. Makris, N. and Deoskar, H., Prediction of Observed Response of Base-Isolated Structure, Journal of Structural Engineering, Vol. 122, No.5, 1996, pp. 485-493 https://doi.org/10.1061/(ASCE)0733-9445(1996)122:5(485)
  5. Takeda, M., Ohkawa, Y. and Akutsu, Y., 'An Evaluation Method for Seismic isolation Effect in Siting of a Nuclear Facility,' Reliability Engineering and System Safety, Vol. 62, 1998, pp. 241-249 https://doi.org/10.1016/S0951-8320(98)00023-4
  6. US NRC Regulatory Guide 1.60, Design Response Spectra for Seismic Design of Nuclear Power Plants, 1973
  7. 김민규, 전영선, Coil Spring & Viscos Damper System의 동적 거동특성분석, 한국지진공학회 논문집 Vol. 11, No.2, 2007, pp. 19-26 https://doi.org/10.5000/EESK.2007.11.2.019
  8. 김민규, 전영선, 최인길, 원전기기의 면진을 위한 진동대 실험 I: 고무베어링, 한국 지진공학회 논문집, Vol. 8, No.5, 2004, pp. 65-77
  9. 김민규, 전영선, 최인길, 원전기기의 면진을 위한 진동대 실험 II: FPS, 한국 지진공학회 논문집, Vol. 8, No.5, 2004, pp. 79-89
  10. 전영선, 최인길, 원전기기의 지진력 저감이 노심손상빈도에 미치는 영향 평가, 한국원자력학회 추계학술발표회, 2002
  11. 최인길, 전영선, 서정문, Development of a Uniform Hazard Spectrum for a Soil Site by Considering the Site Soil Condition, 2004년 원자력학회 추계 학술발표회, 2004
  12. 최인길, 中島正人, 전영선, 연관희, 확률론적 지진재해도를 이용한 시나리오 지진의 결정기법에 관한 연구, 한국지진공학회 논문집, Vol. 8, No.6, 2004, pp. 23-29