버퍼의 넓이가 다른 스너버의 수치해석 비교

The CFD Analysis Comparison of Several Snubbers with different Buffer Width

  • 이경환 (경상대학교 대학원 정밀기계공학과) ;
  • 심규진 (경상대학교 대학원 정밀기계공학과) ;
  • 이용훈 (경상대학교 대학원 정밀기계공학과) ;
  • 정한식 (경상대학교 정밀기계공학과, 해양산업연구소) ;
  • 정효민 (경상대학교 대학원 정밀기계공학과, 해양산업연구소)
  • 발행 : 2007.11.30

초록

Pulsation is an inherent phenomenon in reciprocating compressors. It interacts with piping to cause vibrations and performance problems. Indiscriminately connecting to a compressor can be dangerous and cost money in the form of broken equipment and piping, poor performance, inaccurate metering, unwanted vibration, and sometimes noise. Piping connected to a compressor can materially affect the performance and response. To minimize these detrimental effects, reciprocating compressor system should be equipped by pulsation suppression system. The system usually comprises bottle volume, called snubber. Snubber is one of the most important parts in hydrogen compressing system. It has installed reciprocating hydrogen compressor. One of these components is snubber which has function to reduce pulsation waveform and to remove the impurities in the hydrogen gas. A snubber has an inclined plate as a buffer, which is installed inside snubber. When the pressure loss and the pulsation of pressure within a snubber is minimized, the snubber could get more applicability. Therefore, a study to find an optimum geometric size on a several snubbers which have different buffer width, has been conducted using a numerical analysis.

키워드