Abstract

The seismic fragility analysis method has been used as a quantitative seismic safety evaluation method for the NPP(Nuclear Power Plant) structures and equipments. The seismic fragility analysis gives a realistic seismic capacity excluding the convertism included in the design stage. The conservatism is considered as the probabilistic parameters related to the response and capacity in the seismic fragility analysis. In this study, the displacement based seismic fragility analysis method was proposed based on the nonlinear dynamic analysis results. In this study, the seismic safety of the prestressed concrete containment building of KSNP(Korean Standard Nuclear Power Plant) was evaluated for the scenario earthquakes, neat-fault, far-fault, design earthquake and probability based scenario earthquake, which can be occurred in the NPP sites.

원전 구조물 및 주요기기의 지진 안전성 평가에서는 내진성능을 정량화하는 방법으로 취약도 분석이 사용되고 있다. 지진취약도 분석은 격납건물의 설계 시 반영된 보수성을 배제한 실질적인 내진성능을 평가하는 것으로 이러한 보수성을 성능 및 응답에 관련된 확률론적 변수로 고려하여 평가하게 된다. 본 연구에서는 비선형 지진 해석으로부터 얻은 구조물의 변위응답을 기초로 한 지진취약도 분석 방법을 제시하였다. 또한 원전부지에서 선정된 발생가능한 근거리지진, 원거리지진, 설계지진 및 확률론적 시나리오지진을 시나리오지진으로 선정하고 이들 지진동에 대한 비선형 지진해석을 통하여 한국 표준형 원전 격납건물의 지진취약도를 평가하였다.

Keywords

References

  1. US NRC Regulatory Guide 1.60, Design Response Spectra for Seismic Design of Nuclear Power Plants, 1973
  2. Paul Somerville, 'Characterization of Near-Fault Ground Motions,' US-Japan Workshop on the Effects of Near-Field Earthquake Shaking, San Francisco, California, pp.21-29, 2000
  3. Xu, J., Philippacopoulas, A. J., Miller, C. A. and Costantino, C. J., CARES(Computer Analysis for Rapis Evaluation of Structures), NUREC/CR-5588, Vol. 2, 1990
  4. US NRC Regulatory Guide 1.165, Identification and Characterization of Seismic Sources and Determination of Safe Shutdown Earthquake Ground Motion, 1997
  5. Chopra, A. K., Dynamics of Structures: Theory and Applications to Earthquake Engineering, Prentice- Hall, Inc, 1995
  6. Malhorta, P. K., 'Response of Building to Near-Field Pulse-Like Ground Motions,' Earthquake Engineering and Structural Dynamics, Vol. 28, 1999, pp.1309-1326 https://doi.org/10.1002/(SICI)1096-9845(199911)28:11<1309::AID-EQE868>3.0.CO;2-U
  7. Malhorta, P. K., Effects of Near-Field Pulse-Like Ground Motions on Tall Buildings, 한국지진공학회 추계학술대회 논문집, 1998
  8. Korea Power Engineering Company, Inc. and Sargent & Lundy, 'Design Report : Containment Shell and Dome,' Report No. 9-310-C409-003, Rev. 0, July 16, 1990
  9. ABAQUS, Inc., ABAQUS Version 6.4, 2003
  10. 株式會社 ARK Information System, TDAP III Ver 2.13, 2005
  11. Park, Y. J., Hofmayer, C. H., Technical Guidelines for Aseismic Design of Nuclear Power Plants, Translation of JEAG 4601-1987, NUREG/CR-6241, 1994
  12. Japan Electric Association, Technical Guideliness for a Seismic Design of Nuclear Power Plants, JEAG 4601-1991 Supplement, 1991
  13. Ang ZH-s, Tang, W. H., Probability Concepts in Engineering Planning and Design, Basic Principles, Vol. 1, Wiley, New York, 1975
  14. Read, J. W., Kennedy, R. P., Buttemer, D. R., Idriss, I. M., Moore, D. P., Barr, T., Wooten, K D. and Smith, J. E., A Methodology for Assessment of Nuclear Power Plant Seismic Margin (Revision 1), EPRI NP-6041-SL, 1991
  15. Lee, N.H. and Song, K.B. 'Seismic Capacity Evaluation of the Prestressed/Reinforced Concrete Containment, Young-gwang Nuclear Power Plant Unit 5 & 6,' Nuclear Engineering and Design, 192, 1999, pp.189-203 https://doi.org/10.1016/S0029-5493(99)00108-9
  16. Kennedy, R. P. and Ravindra, M. K., 'Seismic Fragilities for Nuclear Power Plant Risk Studies,' Nuclear Engineering and Design, 79, 1984
  17. Korea Electric Power Company, External Event Analysis for Young-gwang Units 5 & 6 PSA, 2001
  18. Ozaki, M., Okazaki, A., Tomomoto, K., Iba, T., Satoh, R., Nanba, H., Seya, H., Moriyama, K. and Ugata, T. 'Improved Response Factor Methods for Seismic Fragility of Reactor Building,' Nuclear Engineering and Design, 185, 1998