DOI QR코드

DOI QR Code

Calibration of a Five-Hole Pressure Probe using a Single Sector Error Interpolation Model

단일영역 오차보간 모델을 이용한 5-Hole Pressure Probe의 교정

  • Published : 2006.05.31

Abstract

A new calibration method for five-hole pressure probe is presented. This method provides accuracies better than those based on the traditional regression method. The calibration algorithm uses a single sector interpolation response surface calculated by comparing the regression curve fits with the actual calibration data. A five-hole pressure probe with hemispherical tip was fabricated and calibrated at Reynolds number of $4.11{\times}10^6$/m and flow angle of ${\pm}48$ degrees. Two data prediction models, the least-square regression and a single sector error interpolation, were evaluated. The comparison of these two calibration methods to a five-hole probe is described and discussed. An evaluation of the calibration accuracy is also given.

기존의 전통적인 회귀분석 기반 교정방법에 비해 높은 교정정밀도를 얻을 수 있는 5-hole pressure probe의 교정방안을 연구하였다. 이 새로운 교정기법은 교정시험으로부터 획득한 데이터와 곡선적합 결과간의 차이를 이용하여 산정한 단일 영역에 대한 오차보간 반응곡면을 사용한다. 끝단의 직경이 4.0 mm인 5-hole probe를 자체 제작하고, 레이놀즈수$4.11{\times}10^6$/m와 흐름각 ${\pm}48$에서 교정시험을 수행하였다. 최소자승 회귀분석모델과 단일영역 오차보간 모델을 적용하여 자료처리를 수행하고 이들 두 교정방안에 대한 비교평가와 분석을 수행하였으며, 아울러 교정 정밀도에 대한 평가도 수행하였다.

Keywords

References

  1. Gallington, G. G., 'Measurement of Very Large Flow Angles with Non-Nulling Seven-Hole Probes', USAFA-TR-80-17, 1980
  2. Zilliac, G. G., 'Calibration of Seven-Hole Pressure Probes for Use in Fluid Flows with Large Angularity', NASA-TM-102200, Dec. 1989
  3. Wenger, C. W. and Devenport, W. J., 'A Seven-Hole Pressure Probe Measurement System and Calibration Method Utilizing Error Tables', AIAA-98-0202, 1998
  4. Sung, Bongzoo, 'Analysis of the Vortical Flow around a 60 Degree Delta Wing with Vortex Flap', Ph.D. Thesis, Dec. 1985
  5. 성봉주, 장병희, '최소 자승법을 이용한 5-Hole Yawhead Probe의 간략한 보정법', 한국항공우주학회지, 제 16권, 제 2호, June 1988
  6. Bryer, D. W. and Pankhurst, R. C., 'Pressure-probe methods for determining wind speed and flow direction', HMSO, 1971
  7. Everett, K. N., Gerner, A. A. and Durston, D. A., 'Theory and Calibration of Non-Nulling Seven-Hole Cone Probes Suitable for Use in Complex Flow Measurement', AIAA-82-0232, Jan. 1982
  8. Using MATLAB, Version 6.1, The Math Works, Inc., Natick, 2002
  9. Vijayagopal, R., Pathanl, M. M., and Rediniotis, O. K., 'Miniature Multi-Hole Pressure Probe - Neural Network Calibration and Frequency Response Enhancement', AIAA-98-0204, 1998
  10. 오세윤, 안승기, 최장섭, '회귀분석과 보간법을 이용한 5-Hole Probe의 교정', 2004 풍동워크샵, 세미나 II, 2004. 5. 14
  11. Zeiger, M. D., Chalmenta, L. P. and Telionis, D. P., 'Tip Geometry Effects on Calibration and Performance of Seven-Hole Probes', AIAA-98-2810, 1998
  12. 정낙삼 외, '측정불확도 표현 지침', 한국표준과학연구원, 1998

Cited by

  1. An Experimental Study of Test Section Velocity Calibration for Low-Speed Wind Tunnel vol.40, pp.3, 2012, https://doi.org/10.5139/JKSAS.2012.40.3.230