References
- Engh, C.A. and Bobyn, J.D. 'The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty,' Clin. Orthop., Vol. 231, pp. 7-28, 1988
- Albrektsson, T. and Albrektsson, B., 'Osseointegration of bone implants. A review of alternative mode of fixation,' Acta Orthop Scand, Vol.58, p567, 1987 https://doi.org/10.3109/17453678709146401
- Briitish orthopedic research society-JBJS, suppl IV 79B, p465, 1997
- Burke, D.W., Bragdon, C.R., O'Connor, D., 'Dynamic measurement of interface mechanics in vivo and the effect of micromotion on bone ingrowth into a porous coated surface device under controlled loads in vivo Trans,' 37th Annual ORS, Vol. 16, pp. 103, 1991
- Albrektsson, T., Carlsson, L.V., Morberg, P. and Wennergberg, A., 'Direct Bone-Anchored Implants; With Special Emphasis on the Concept of osseointegration in Orthopedic Surgery,' Bone Implant Interface, Mosby-year Book, Inc, 1994
- Capello, W.N. and Bauer, T.W., 'Hydroxy apatite in orthopedic Surgery,' Bone Implant Interface, by Mosby-year Book, Inc, 1994
- Charnley, J., 'Total hip replacement by low friction arthorplasty,' Clin. Orthop. Rel. Res., Vol. 72, pp. 7-21, 1972
- Charnley, 'Acrylic Cement in Orthopedic Surgery,' Williams and Wilkins, Baltimore, pp. 213-358, 1970
- Korea Health Industry Development Institute, 'Medical device industry white book,' 2004
- Oppenheim research, 11/2003
- Rush-Presbyterian-St., Luke's Medical Center, Chicago, 'Wear debris in Total Joint replacements,' AAOS, Vol. 2, No.1, pp. 212-220, 1994 https://doi.org/10.5435/00124635-199407000-00004
- Cameron, H.U., 'A review of the 2 to 8 year results with a proximally fixed noncemented threaded modular total hip.,' Acta Orthop, Belg, Vol. 58, pp. 420, 1992
- Thompson, M.S., 'The design of a Novel Hip Resurfacing Prosthesis,' Ph.D. thesis, Queen Mary and Westfield College, University of London, 2001
- Wagner, H., 'Surface replacement arthroplasty of the hip.,' Clin. Orthop. Rel. Res., Vol. 134, pp. 102-30, 1978
- Huiskes, R., Strens, P., Vroemen, W., Slooff, T.J., 'Post-loosening Mechanical Behavior of Femoral Resurfacing Prosthesis,' Clin. Mat., Vol. 6, pp. 37-55, 1990 https://doi.org/10.1016/0267-6605(90)90043-U
- Spears, I.R., Pfleiderer, M., Schneider, E., Hille, E., Morlock, M.M., 'The effect of interfacial parameters on cup-bone relative micromotions: A finite element investigation,' J. Biomech., Vol. 34, pp. 113-120, 2001 https://doi.org/10.1016/S0021-9290(00)00112-3
- William, G.W., Karen, S.J., Frederick, J.D., and Jeffrey, J.E., 'Extramedullary porous coating to prevent diaphyseal osteolysis and radiolucent lines around proximal tibia replacement,' J. Bone Joint Surgery Am, Vol.75, pp. 976-987, 1993 https://doi.org/10.2106/00004623-199307000-00003
- Kim, K.C., Shin, H.K., Son, K.M., Ko, C.S., 'The Treatment of Unstable Intertrochanter Fracutures of Femur - Comparison between Proximal Femoral Nail and Dynamic Hip Screw,' Journal of the Korean Fracture Society, Vol. 18, No.4, October, 2005 https://doi.org/10.12671/jkfs.2005.18.4.369
- Burstein, A.H., Currey, J., Frankel, V.H., Heiple, K.G., Lunseth, P., Vessely, J.C .. 'Bone strength: the effect of screw holes,' J. Bone Joint Surg Am, Vol.54 pp.1143-1156, 1972 https://doi.org/10.2106/00004623-197254060-00001
- Bartucci, E.J., Gonzalez, M.H., Cooperman, D.R.., 'The effect of adjunctive methylmethacrylate on failures of fixation and function in patients with intertrochanteric fracture and osteoporosis,' J. Bone Joint Surg Am, Vol. 67, pp1084-1107, 1985 https://doi.org/10.2106/00004623-198567070-00014
- Branemark, P.I., Adell, R., Albrektsson, T., Lekholm, U., Lundkvist, S. and Rockier, B., 'Osseointegrated titanium fixtures in the treatment of edentulousness,' Biomaterials, Vol.4, No.1, pp. 25-28, 1983 https://doi.org/10.1016/0142-9612(83)90065-0
- Perel, ML., 'Parafuntional Habits, Nightguards, & Root Form Implants,' Implant Dent, Vol. 3, pp. 261-263, 1994 https://doi.org/10.1097/00008505-199412000-00011