Abstract
The purpose of this paper is to evaluate the fire resistance of the TSC beam, a composite beam composed of a concrete beam enclosed by steel plates. Since a discrepancy was observed between the structural mechanisms of TSC and typical composite beams, the fire performances of the two beams are likewise believed to be partially dissimilar. In this experiment, small and medium-sized TSC beams were tested under given conditions in the laboratory, with/without one of the most widely used spray-on fire protections in Korea. Furthermore, based on the steel and concrete properties under elevated temperatures that were obtained from Eurocode, temperature development across the section was suggested, analyses. To determine the capacity of a modified plastic section, th e fire performance of the model was also examined.
복합 구조 시스템은 강재와 콘크리트의 합성으로 내화성능이 우수할 것으로 판단된다. 그러나 복합구조의 내화성능에 대한 연구는 아직 초기 단계로 기둥과 보 등의 부재에 대한 내화실험 결과가 일부 발표 되었으나 합성보에 대한 자료는 거의 없다. 이에 본 연구에서는 TSC 합성보의 내화성능 평가를 위해 내화실험과 수학적 및 수치 해석적인 방법을 통해 평가하였다. 내화실험은 형상의 종류와 가력 하중, 내화피복재 보강방법 등을 변수로 실험을 실시하였다. 또한 수치 해석 중 강재와 콘크리트의 재료특성은 Eurocode에 준하였으며 온도의 변화는 열전도 FE 해석과 수학적인 방법을 사용하였다.