• Title/Summary/Keyword: Multi-family houses

검색결과 80건 처리시간 0.027초

해외 집합주택의 공유공간 계획특성 연구 - 유럽, 일본, 중미지역사례를 중심으로 - (A Study on the Design Characteristics of Communal Spaces in multi-family Houses - Focused on Case Studies on Europe, Japan and Middle America -)

  • 이민석
    • 한국실내디자인학회논문집
    • /
    • 제22권3호
    • /
    • pp.174-182
    • /
    • 2013
  • The purpose of this research is to find applicable design characteristics of communal spaces in multi-family houses. With this goal, international multi-family housing projects are selected and their communal spaces are identified. The purpose of study lies in analyzing on recent 10 years trends of shared space of multi-family houses in Europe, Japan, central America. The design characteristics of the communal spaces are analyzed with a special focus on the four Aspects such as Organization of space, access roads, parking, pedestrian movement In terms of the framework for analysis, community, rest, separability, rambling, territory, distribution, entrance, openness, view, prospect and aesthetic characteristics are reviewed. As a result, the communal space of the analysis are integrated in plans and sections throughout the multi-family houses. Openness and connection with surrounding urban environments are articulated by communal spaces. Communal identities and aesthetics are emphasized by various space for dweller and the other inhabitant. For a further research, it is necessary to combine a design method study with new multi-family houses for the future.

최신 자연채광 디자인 사례들 분석 및 그 적용에 관한 연구 - 미국 LEED 인증 공동주택 사례분석을 바탕으로 - (Study on the Analysis and the Application of State-of-the-Art Daylighting Design Cases - Based on the Case Studies of LEED(Leadership in Energy and Environmental Design) Multi-Family housing -)

  • 윤혜경
    • 한국실내디자인학회논문집
    • /
    • 제22권1호
    • /
    • pp.265-273
    • /
    • 2013
  • The purpose of this study is to analyze the state-of-the-art daylighting design among LEED(Leadership in Energy and Environmental Design) multi-family housing cases and to explore the feasibilities for their applications in domestic housing design. Occupants in multi-family houses are reported to consume more electricity power than those in single houses. That may imply the problems of daylighting design in domestic housing design for multi-family houses have better insulation system and less windows and outside walls than single houses. Therefore two systems, daylight delivery system and daylight control system, are scrutinized for daylighting design with LEED cases. The findings show when windows as a daylight delivery system are combined with overhangs, fins, louvers, fenestration materials, speciality fenestration, or interior controls as a daylight control system, the outcome goes with more energy savings and better facade design. Beside those, lightshelves as a daylight delivery system seem to have potentials in domestic multi-family houses with deep plans and less outside walls. Daylighting designs in domestic multi-family houses need to pursue available options more to achieve the integration of energy and aesthetics values.

공동주택의 실내공간구성에 대한 확대 및 노인가족 노인의 선호 - 울산지역의 공동주택 거주 노인을 중심으로 - (Preference of the Old-aged for Interior Space Organization of Multi-family Houses - Focused on the Elderly of Multi-family Houses in Ulsan -)

  • 이춘엽;오찬옥
    • 한국실내디자인학회논문집
    • /
    • 제18권6호
    • /
    • pp.3-11
    • /
    • 2009
  • The ratio of old persons among the total population is rapidly increasing and the apartment has become to the representative housing type in Korea. This means that many old persons would live in multi-family houses. Therefore the study was intended to examine the preferred characteristics of interior space organization in multi-family house by the aged. The characteristics were the number and usage of bedroom, necessity and type of dress room, type of living room, arrangement of work centers in kitchen, LDK type, the number and layout of bathroom, and type of entrance and balcony. The subjects were 122 old persons who lived in multi-family houses in Ulsan. The individual interview was carried out for collecting the data. The results were as the followings; The characteristics of interior space organization in multi-family houses preferred by the elderly were three bedroom, two bathroom, DK or LDK type, open planned living room, L shape arrangement of kitchen work center, entrance connected directly to outdoor space such as elevator hall or corridor, and the balcony located in front of living room and at the back of small bedroom. Even thouth the average age of population has increased, many apartments still be planned and provided without consideration of old persons. This study would contribute to plan the multi-family houses for the elderly.

신축공동주택에서의 실내공기 오염물질 방출 저감 프로세스에 관한 연구 (A Study on a Proper Reduction Process of Indoor Air Pollutants In Newly-Constructed Multi-Family Houses)

  • 유형규;박진철;이언구
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.468-476
    • /
    • 2005
  • The purpose of this study is to investigate actual air quality in newly-constructed multi-family houses and to improve Indoor Air Quality (IAQ). The field measurement was conducted in four different newly-constructed multi-family house complexes in Seoul and one existing multi-family house complex in Kyong-gi province. The result of the measurement shows that indoor concentrations of Formaldehyde and TVOC in newly-constructed multi-family houses are much higher than the foreign standards. To establish a proper process for reducing indoor air pollutants, various experiments have been conducted; application of natural materials, bake-out practice, closure of all openings without ventilation, and use of mechanical ventilation system. The result indicates that three practices (natural materials, bakeout, mechanical ventilation) can reduce the level of indoor air pollutants almost in half during the experiments. However, each practice has its limitation and is insufficient to satisfy IAQ standards. Therefore, the study proposes a proper reduction process of indoor air pollutants which combines four different practices in time sequence.

실물 주거 시공을 통한 실내공기질에 영향을 미치는 주요 건축자재 및 시공방법에 관한 연구 (A Study on the Major Building Material and Construction Method Influencing to IAQ through Full-Scale House Construction)

  • 유형규;박진철;이언구
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.262-269
    • /
    • 2006
  • Formaldehyde and total volatile organic compounds (TVOC) from building materials have been known as main causes of IAQ problem in Newly-Constructed Multi-Family Houses. Because Multi-Family Houses are built in large quantities in a similar manner, inappropriate selection of building materials and method will detrimental affect IAQ. This research aims to identify major causes of Indoor Air Pollutants in Multi-Family Houses, by constructing Mock-Up & One-Room House. As a result, self leveling concrete, door, and furniture construction is a major cause of indoor formaldehyde increase, and tile bond is TVOC, and urethane water proof is Etylbenzene, and Xylene.

대학주변 원룸형 다가구주택의 계획 방향에 관한 연구 (A Study On the Direction of Planning for One-Room Type Multi-Family Housing Around Campus)

  • 이혜정;홍영애;김성화;권소현;최무혁
    • 한국주거학회논문집
    • /
    • 제10권2호
    • /
    • pp.165-173
    • /
    • 1999
  • Around campus, one-room type multi-family houses have been built for more than any other types of one-room type dwelling units. However, these houses are built in a very small scale and have insufficient facilities due to the limited capital invested by the owners of the houses. Consequently, one-room type multi-family housing are lack of consideration and care for various dwellers. This study examines the existing condition of one-room type multi-family housing around campus and analyzes the data collected from the interviews and analyses of the floor plans of the housing. Finally, based on the findings from the analyses this study suggests the future direction for the planning of one-room type multi-family housing.

  • PDF

공동주택 최대난방부하 계산법의 분석 (An analysis of the Design heating load calculation in multi-family houses)

  • 조동우
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.26-32
    • /
    • 2000
  • Design load calculations which depend on the thermal characteristics of the building structure such as the wall, roof, and fenestration provide the basic data for selecting an HVAC system and its equipment. Most of domestic multi-family houses include a high thermal storage layer like massive concrete structure and a floor heating structure. This study is to compare the results of the design heating load between steady state and unsteady state calculation in order to comprehend the thermal storage effect in multi-family houses. The design heating load under the steady state calculation is estimated from 5.4% to 7.8% larger than that under the unsteady state in the typical floor of a multi-family house model. The design heating load considered the safety factors like a orientation and location factor also is 21.4% to 26.5% larger than that by the unsteady state calculation. So, the safety factors for use of the practicing engineer are analyzed as the main factor of a heating plant oversizing.

  • PDF

공동주택 거주자의 주거관리의식 - 서울시 아파트와 연립, 다세대 주택을 중심으로 - (Attitude of resident to the management of multihousing - In case of aparment and raw houses, multi-family houses)

  • 강순주
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 1994년도 학술발표대회논문집 상
    • /
    • pp.37-44
    • /
    • 1994
  • The purpose of this research is to present necessity of manament system establishment and policy direction for fundmental data, understanding management reality and problem, comparing resident's management attitude to related variables in apartment and raw houses multi-family houses. The major finding were as follows : 1) The management attitude of Apartment inhabitant is very highm especially the attitude of maintenance management is the higest. But they disagree with the raise of management cost necessary to maintenance management. 2) The management attitude of Raw multi-family houses inhbitant is especially high, the maintenance management demand for safety and community-life contol attitude, resident's mutual cooperation is especially high, they think much of autonomy management, desire to achieve under more sysemnatic plan.

  • PDF

다가구.다세대주택 소유자의 주거환경 개선 및 활용 요구에 관한 연구 (A Study on the Needs of the utilization and improvement of the multi-family housing residence)

  • 김혜연;이영선;장미선;이연숙
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.135-139
    • /
    • 2008
  • Through the industrialization since 1960, Korean housing has been developed in a uniform way which is to demolish first and then construct from the scratch. In this process, detached houses and multi-family living detached houses have disappeared without being paid much attention. The detached houses with blood or non-blood related multi-family living situations are typically popular, and worthy enough to explore for professionals right and creative solutions to enhance their values. But many of the people suffered for the expenses and the absence of the idea to enhance their housing themselves. The purpose of this research is to clarify user's demands of developing an adaptable lifespan house and to try to find the solution about the expenses of self improvement. This study used a Small group workshop Panel Method. The workshop consisted of three stage, such as the awareness of their existing residence and lease status, the needs of the housing improvements and the demands of the adaptable house. This study is expected to serve as a fundamental data to promote discussion on reuse of existing residence building and to promote rental detached houses.

  • PDF

대학생 거주 원룸형 다가구주택의 겨울철 실내열공기환경 실태 (The Indoor Thermal and Air Environment during Winter in One-room Type Multi-family Houses Occupied by University Students)

  • 최윤정;김운학
    • 한국생활과학회지
    • /
    • 제19권4호
    • /
    • pp.745-760
    • /
    • 2010
  • The purposes of this study were to investigate the state of indoor thermal and air environment during winter in the one-room type multi-family houses occupied by university students and to analyze factors which influenced this environment. Field survey was conducted in 10 houses between 30th January, 2009 and 13th February, 2009 which measured indoor thermal and air elements as well kept records of interviews with residents and other related factors. Measured elements were air temperature, relative humidity, as well as concentrations of $CO_2$, CO, TVOC, and PM-10. The results can be summarized as follows. 1) The mean air temperature in each house ranged from 19.3 to $25.3^{\circ}C$, so most houses were not suitable for evaluation criteria($20-22^{\circ}C$). The average $CO_2$ concentration in each house was 965~3259ppm, so most houses exceeded evaluation criteria(1000ppm). The average TVOC concentration in each house were 0.00~1.17ppm, 5 houses exceeded evaluation criteria(0.12ppm). 2) Relative humidity, CO concentration, and PM-10 concentration were suitable for evaluation criteria. Therefore, indoor thermal and air environment during winter in one-room type multi-family housing occupied by university students was found to be generally uncomfortable. Important factor which were found to influence air temperature and the concentration of $CO_2$ were smaller space capacity than general house. Other factors which were found to influence the environment of these houses were the existence of a balcony as well as factors relating to the behavior of occupants such whether or not heating were operated, whether windows were opened, whether fans used, whether occupants smoked or used cosmetics, and whether the space was dusted.