Abstract
Recently, pre-engineering building (P.E.B.) systematic frames are increasingly being used in steel factory buildings, but almost of the related techniques are dependent on the engineering program (e.g, MBS, LTI), which is usually imported from other countries. These are designed under the AISC-ASD because at present there is no Korean design code for P.E.B. frames. Also, there are few studies onbehaviour and we need to develop the element techniques by using H-shaped components.In particular, there is a tendency towards overestimated design because column-rafter connections have been designed with extended end plate type joint, which is treated asrigid joint,so structural examinations are needed. Therefore, this study represents a basic step in ascertaining the application of P.E.B. systematic frames by using H-shaped column-rafter connectionwith flush type end plate. Its structural performance is compared with that of existing extended type joint using a structural performance test. The structural behaviour of specimen was understood qualitatively and the possibility of application (e.g, design aid charts) of semi-connection (flush type) with H-shaped column-rafter was determined.
최근 들어 강구조 공장건축은 상당부분 P.E.B.시스템으로 지어지고 있으나 관련기술이 대부분 외국에서 수입된 것으로 전용프로그램(예, MBS, LTI 등)에만 의존하고 있고 국내의 설계지침이 없어서 AISC-ASD에 의해 설계하고 있다. 또한 P.E.B.골조의 구조적 거동을 검토한 연구 및 H형강을 이용한 요소기술 개발이 부족한 실정에 있다 특히, 기둥-보(rafter) 접합부는 Extended type end plate에 의한 접합에만 의존하여 과다설계의 경향이 있으므로. 접합부에 대한 구조적 검토가 필요하다. 따라서 이 연구에서는 P.E.B.시스템 공장건물에서 H형강-보(rafter)의 접합부(Extended/Flush type)의 구조성능을 실험적으로 평가하여 구조적, 경제적으로 우수한 P.E.B. 시스템 골조의 설계를 위한 기초자료를 제공하고자 한다.