References
- Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 18:269-296, 1974.
- Skidmore AE, Bjorndal AM. Root canal morphology of the human mandibular first molar. Oral Surg Oral Med Oral Pathol 32:778-784, 1971. https://doi.org/10.1016/0030-4220(71)90304-5
- Weine F, Kelly R, Lio P. The effect of preparation procedures on the original canal shape and on apical foramen shape. J Endod 1:255-262, 1975. https://doi.org/10.1016/S0099-2399(75)80037-9
- Walia H, Brantely WA. Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endod 14:346-351, 1988. https://doi.org/10.1016/S0099-2399(88)80196-1
- Glosson CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. J Endod 21:146-151, 1995 https://doi.org/10.1016/S0099-2399(06)80441-3
- Serene TP, Adams JD, Saxena A. Nickel-titanium instruments: applications in endodontics. St. Louis, Mosby. 67-78, 1995
- Barbakow F, Lutz F. The 'Lightspeed' preparation technique evaluated by Swiss clinicians after attending continuing education courses. Int Endod J 30:46-50, 1997. https://doi.org/10.1111/j.1365-2591.1997.tb01097.x
- Zuolo ML, Walton RE. Instrument deterioration with usage: Nickel-Titanium versus stainless steel. Quintessence Int 28:397-402, 1995.
- Mandel E, Adib-Yazdi M, Benhamou LM, Lachkar T, Mesgouez, Sobel M. Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage. Int Endod J 32:436-443, 1999. https://doi.org/10.1046/j.1365-2591.1999.00239.x
- Ruddle C. Cleaning and shaping the root canal system. Pathways of the Pulp, 8th ed. St. Louis, Mosby, 231-292, 2002.
- Sattapan B, Nervo GJ, Palamara JEA, Messer HH. Defect in rotary nickel-titanium files after clinical use. J Endod 26:161-165, 2000. https://doi.org/10.1097/00004770-200003000-00008
- Haikel Y, Serfaty R, Bateman G, Senger B, Allemann C. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instrument. J Endod 25:434-440, 1999. https://doi.org/10.1016/S0099-2399(99)80274-X
- Gambarini G. Cyclic fatigue of Profile rotary instruments after prolonged clinical use. Int Endod J 34:386-389, 2001. https://doi.org/10.1046/j.1365-2591.2001.00259.x
- Pruett JP, Clement DJ, Carnes Jr. DL. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 23:77-85, 1997. https://doi.org/10.1016/S0099-2399(97)80250-6
- Gary C. Influence of material properties on the rotational speed of engine-driven nickel-titanium instrument. Contemporary Endod 28-30, 2002.
- Mize SB, Clement DJ, Carnes DL, Pruett JP. Effect of sterilization on cyclic fatigue of Ni-Ti instruments. Abstracts of research. AAE 54th session. J Endod 23(OR9):251, 1997. https://doi.org/10.1016/S0099-2399(97)80066-0
- Yared GM, Bou Dagher FE, Machtou P. Cyclic fatigue of Profile rotary instruments after clinical use. Int Endod J 33:204-207, 2000. https://doi.org/10.1046/j.1365-2591.1999.00296.x
- Peters OA, Barbakow F. Dynamic torque and apical forced of ProFile .04 rotary instruments during preparation of curved canals. Int Endod J 35:379-389, 2002. https://doi.org/10.1046/j.0143-2885.2001.00494.x
- Booth JR, Sheetz JP, Lemons JE, Eleazer PD. A comparison of torque reqiured to fracture three different nickel-titanium rotary instruments around curves of the same angle but of different radius when bound at the tip. J Endod 29:55-57, 2003. https://doi.org/10.1097/00004770-200301000-00015
- Gambarini G. Cyclic fatique of nickel-titanium rotary instruments after clinical use with low- and high torque endodontic motors. J Endod 27:772-774, 2001. https://doi.org/10.1097/00004770-200112000-00015
- 조종춘 외. 금속손상진단. 서울, 진영사 15-41, 2002
- 이동령. 금속강도학. 서울, 문운당 219-291, 1985
- Zinelis S, Margelos J. Aging of endodontic instruments and materials. Eliades G, Eliades T, Brantley W, Watt DC eds. Dental materials in vivo: aging and related phenomena. Carol Stream, Quintessence Publishing Co Inc, 180-186, 2003