References
- M. A. Northrup, M. T. Ching, R. M. White, and R. T. Watson, 'DNA amplication with a microfabricated reaction chamber', Proc. Int. Conf. Solid-State Sensors and Actuators, pp. 924-926, 1993
- M. U. Kopp, A. J. de Mello, and A. Manz, 'Chemical amplification: Continuous-flow PCR on a chip, Science', Science, vol. 280, pp. 1046-1048, 1998 https://doi.org/10.1126/science.280.5366.1046
- J. H. Daniel, S. Iqbal, R. B. Millington, D. F. Moore, C. R. Lowe, D. L. Leslie, M. A. Lee, and M. 1. Pearce, 'Silicon microchambers for DNA amplification', Sensors and Actuators A, vol. 71, pp. 81-88, 1998 https://doi.org/10.1016/S0924-4247(98)00158-7
- A. Fuchs, H. Jeanson, P. Claustre, J. A. Gruss, F. R. Cavalier, P. Caillat, U. Mastromatteo, M. Scurati, F. Villa, G. Barlocchi, P. Corona, and B. Grieco, 'A silicon lab-on-chip for integrated sample preparation by PCR and DNA analysis by hybridization', lnt. Conf. on Microtechnologies in Medicine & Biology, pp. 227-231, 2002
- Y.-K. Kim, 'The Trend of MEMS Technology', J. Sensors Soc., vol. 8, no. 5, pp. 354-358, 1999
- D. S. Yoon, Y. S. Lee, H. J. Cho, S. W. Sung, K. W. Oh, J. H. Cha, and G. B. Lim, 'Precise temperature control and rapid thermal cycling in a micro-machined DNA polymerase chain reaction chip', J. Micromechanics and Microengineering, vol. 12, pp. 813-823, 2002 https://doi.org/10.1088/0960-1317/12/6/312
- S. L.-Esteban, E. Saiz, S. Fujino, T. Oku, K. Suganuma, and A. P. Tomsia, 'Bioactive glass coatings for orthopedic metallic implants', J. of the Europ. Ceramic Soc., vol. 23, pp. 2921-2930, 2003 https://doi.org/10.1016/S0955-2219(03)00303-0
- J. Ballarre, J. C. Orellano, C. Bordenave, P. Galliano, and S. Cere, 'In vivo and in vitro evaluation of vitreous coatings on cobalt base alloys for prosthetic devices', J. of Non-Cry st. Solids, vol. 304, pp. 278-285, 2002 https://doi.org/10.1016/S0022-3093(02)01035-9
- C. denBesten, R. E. G. van Hal, J. Munoz, and P. Bergveld, 'Polymer bonding of micro-machined silicon structures, micro electro mechanical systems', IEEE MEMS. vol. 92, pp. 104-107, 1992
- J. E.-Ali, I. R. P.-Nielsen, C. R. Poulsen, D. D. Bang, P. Telleman, and A. Wolff, 'Simulation and experimental validation of a SU-8 based PCR thermocycler chip with integrated heaters and temperature sensor', Sensors and Actuators A, vol. 110, pp. 3-10, 2004 https://doi.org/10.1016/j.sna.2003.09.022
- E. Kukharenka, M. M. Farooqui, L. Grigore, M. Kraft, and N. Hollinshead, 'Electroplating moulds using dry film thick negative photoresist', J. Micro-mechanics and Microengineering, vol. 13, pp. S69-S74, 2003
- K.-D. Song, Y.-1. Bang, S.-M. Lee, Y.-S. Lee, N.-J. Choi, B.-S. Joo, M.-G. Seo, J.-S. Huh, and D.-D. Lee, 'Characteristics and fabrication of micro gas sensor with single electrode', J. Sensors Soc., vol. 111, no. 6, pp. 350-357, 2002
- A. F. R. Huhmer and J. P. Landers, 'Noncontact infrared-mediated thermocycling for effective polymerase chain reaction amplification of DNA in nanoliter volumes', Anal. Chem., vol. 72, pp. 5507-5512, 2000 https://doi.org/10.1021/ac000423j
- D. K. Schroder, R. NoelThomas, and J. C. Schwartz, 'Free carrier absorption in silicon', IEEE J. Solid State Circuits, vol. SC-13, pp. 180-187, 1978