Abstract

It is growing the application of the removal ground anchor with tension force for earth retaining constructions in the downtown. Nowadays, we can find the compression dispersion anchor on many site. But, it is occur some probelems in behabior of anchors because of impossible to tense p.c strand uniformly with existing equipment due to different length of p.c strand. So we tried to tense each p.c strand uniformly with auto back equipment in-situ test. This study compared and analyzed apply to elastic theory in-situ test results of an existing equipment with those of auto back equipment. As a result of the test, It has been proved that differences of tension force in the existing equipment increases with increasing the number of p.c strand. This can cause an ultimate failure of the concentrated p.c strand and a shear failure of ground. So it has been proved that auto back equipment is necessary.

도심지의 흙막이 공사에서 앵커의 인장력에 의해 굴착면을 지지하는 제거식 그라운드 앵커의 사용성이 중시되고 있다. 현재 현장에서 주로 이용되고 있는 압축분산형 앵커는 강선의 길이가 달라 기존 인장장치로 긴장력 도입시 일정한 긴장력을 취할 수 없어 앵커 거동에 문제점을 야기하고 있다. 따라서 Auto back 인장장치를 사용하여, 각 강선에 일정한 긴장력의 도입을 시도하는 현장실험을 실시하였다. 본 연구는 기존 인장장치와 Auto back 인장장치의 현장실험에 따른 실험결과치를, 탄성론에 의거하여 계산된 이론치와 비교 분석하였다. 그 결과 기존 인장장치는 강선의 수가 증가할수록 긴장력 차이가 더 증가하고 있음이 확인되었다. 이는 하중이 집중된 강선의 극한파괴와 지반의 전단파괴를 야기할 수 있다. 따라서 Auto back 인장장치에 의한 긴장이 이루어져 강선에 긴장력을 균등 분배해야 한다.

Keywords