Browse > Article

Application of Removable Ground Anchor Using Auto back Equipment  

Lee, Song (서울시립대학교 토목공학과)
Lee, Sung-Won (서울시립대학교 토목공학과)
Park, Sang-Kook ((주)주춧돌 ENG)
Kim, Sa-Dong ((주)젠트로 ENG)
Publication Information
Journal of the Korea institute for structural maintenance and inspection / v.8, no.4, 2004 , pp. 223-230 More about this Journal
Abstract
It is growing the application of the removal ground anchor with tension force for earth retaining constructions in the downtown. Nowadays, we can find the compression dispersion anchor on many site. But, it is occur some probelems in behabior of anchors because of impossible to tense p.c strand uniformly with existing equipment due to different length of p.c strand. So we tried to tense each p.c strand uniformly with auto back equipment in-situ test. This study compared and analyzed apply to elastic theory in-situ test results of an existing equipment with those of auto back equipment. As a result of the test, It has been proved that differences of tension force in the existing equipment increases with increasing the number of p.c strand. This can cause an ultimate failure of the concentrated p.c strand and a shear failure of ground. So it has been proved that auto back equipment is necessary.
Keywords
Removal ground anchor; Auto back equipment; Compression dispersion anchor;
Citations & Related Records
연도 인용수 순위
  • Reference