Progress in Medical Physics (한국의학물리학회지:의학물리)
- Volume 15 Issue 4
- /
- Pages.228-236
- /
- 2004
- /
- 2508-4445(pISSN)
- /
- 2508-4453(eISSN)
Characterization of Rabbit Retinal Ganglion Cells with Multichannel Recording
다채널기록법을 이용한 토끼 망막 신경절세포의 특성 분석
- Published : 2004.12.01
Abstract
Retinal ganglion cells transmit visual scene as an action potential to visual cortex through optic nerve. Conventional recording method using single intra- or extra-cellular electrode enables us to understand the response of specific neuron on specific time. Therefore, it is not possible to determine how the nerve impulses in the population of retinal ganglion cells collectively encode the visual stimulus with conventional recording. This requires recording the simultaneous electrical signals of many neurons. Recent advances in multi-electrode recording have brought us closer to understanding how visual information is encoded by population of retinal ganglion cells. We examined how ganglion cells act together to encode a visual scene with multi-electrode array (MEA). With light stimulation (on duration: 2 sec, off duration: 5 sec) generated on a color monitor driven by custom-made software, we isolated three functional types of ganglion cell activities; ON (35.0
망막의 신경절세포는 눈에 가해진 시각 정보를 흥분파의 형태로 변환하여 시신경을 통하여 대뇌의 시각피질까지 전달한다. 과거에 사용하여 왔던 방법은 단일 전극을 단일 뉴론의 세포내, 외에 삽입함으로써 특정 시간대에 특정 뉴론만을 기록하는 방법이었으므로 신경망 전체를 통하여 처리되어 나오는 정보를 알아보기에는 적합하지 않다. 다행히 최근에 다채널 전극을 사용하여 여러 신경세포에서 나오는 신호를 동시에 기록할 수 있는 다채널기록법(multichannel recording) 이 개발되었으므로 본 연구에서는 8행
Keywords