Analysis of the Condenser Stack Effect in a High-Rise Apartment Building

고층 아파트에서 응축기 적층문제 분석

  • Published : 2004.09.01

Abstract

The stack effect of a new type condenser installed in a high-rise apartment building was studied numerically A sirocco fan is introduced to the new type condenser instead of an axial flow In. The new type condenser intakes the cold air through the lower inlet and exhausts the hot air through the upper outlet. The effects of the building height and frontal wind on the performance of an air-conditioner were analyzed. The performance of an air-conditioner was evaluated by using COP (coefficient of performance) and CGPI (condenser group performance indicator). the hot air was exhausted by the new type condenser at an angle of 50$^{\circ}$ from the outer wall of the building. If there was no draft, the new type condenser installed in the high-rise apartment building had a good performance and its performance on each floor is not influenced by the stack effect. It is shown that the efficiency of the air-conditioner installed in several floors below the top floor decreased when the frontal wind velocity was greater than 8 m/s.

Keywords

References

  1. Applied Thermal Engineeing v.19 Prediction of on-coil temperature of condensers installed at tall building re-entrant Chow, T.T.;Lin, Z. https://doi.org/10.1016/S1359-4311(98)00042-8
  2. Applied Thermal Engineering v.21 Flow analysis of condenser cooling air delivery via building light well Chow, T.T.;Lin, Z.;Wang, Q.W. https://doi.org/10.1016/S1359-4311(00)00084-3
  3. Building and Environment v.37 Influence of clearances on the energy performance of window-type air-conditioners at the same level outside residential buildings Bojic, M.;Lee, M.;Yik, F.;Burnett, J. https://doi.org/10.1016/S0360-1323(01)00075-0
  4. Energy and Buildings v.32 Effect of building re-entrant shape on performance of air-cooled condensing units Chow, .T.T.;Lin, Z.;Wang, Q.W. https://doi.org/10.1016/S0378-7788(99)00048-1
  5. Energy and Buildings v.34 Influence of a depth of a recessed space to flow due to air-conditioner heat rejection Bojic, M.;Lee, M.;Yik, F. https://doi.org/10.1016/S0378-7788(01)00078-0
  6. SAREK Journal v.15 no.7 Analysis of the condenser performance installed in the air-conditioning plant room of a high-rise building Choi, S.H.;Lee, K.S.;Kim, B.S.
  7. Fluent Version 5.0 Users Manual
  8. Numerical Heat Transfer and Fluid Flow Patnakar, S.V.
  9. Empirical correlation
  10. Journal of Wind Engineering and Industrial Aerodynamics v.67;68 Calculation of the flow past a surface-mounted cube with two-layer turbulence models Lakehal, D.;Rodi, W.