Pressure Drop in Motionless Mixers

  • Yang, Hei-Cheon (School of Applied Engineering, Yosu National University) ;
  • Park, Sang-Kyoo (School of Applied Engineering, Yosu National University)
  • 발행 : 2004.03.01

초록

A motionless mixer consists of a straight pipe or transfer tube containing the mixing elements that are used to cut, fold, twist, and re-combine the mixing fluid. The number of elements and their shape required in any application depend on the complexity of the mixing process. The objectives of this study are to develop new motionless mixers and to perform the experimental investigation of pressure drop in order to evaluate the performance of the new ones. Glycerin is used as a mixing fluid. Pressure drop is measured using a hydraulic manometer and correlations of friction factor are proposed as a function of Re. The friction factors of Sulzer SMX mixer are in qualitative good agreement with the published data. On the average, the friction factors of SSC and YNU mixers are about 36% lower than and 6% higher than that of the Sulzer one.

키워드

참고문헌

  1. Bauman, I., 2001, 'Solid-Soild Mixing with Static Mixers,' Chem. Biochem. Eng., Vol. 15, No. 4, pp. 159-165
  2. Chandra, K. G. and Kale, D. D., 1992, 'Pressure Drop for Laminar Flow of Viscoelastic Fluids in Static Mixers,' Chem. Eng. Sci., Vol. 47, pp. 2097-2100 https://doi.org/10.1016/0009-2509(92)80327-9
  3. Cybulski, A. and Werner, K., 1986, 'Static Mixers-Criteria for Applications and Selection,' Int. Chem. Eng., Vol. 26, pp. 171-180
  4. Hobbs, D. M., 1997, 'Characterization of a Kenics Static Mixer Under Laminar Flow Conditions,' Ph. D. Thesis, The State University of New Jersey
  5. Jaffer, S. A. and Wood, P. E., 1998, 'Quantification of Laminar Mixing in the Kenics Static Mixer : An Experimental Study,' The Canadian J. of Chem. Eng., Vol. 76, pp. 516-521 https://doi.org/10.1002/cjce.5450760323
  6. Kalbitz, H., 1990, 'Effect of Static Mixer on the Flow, Heat Transfer and Pressure Drop in Tube Heat Exchanger,' Ph. D Thesis of University of Braunschweig (TU), Braunschweig, Germany
  7. Li, H. Z., Fasol, C. H. and Choplin, L., 1996, 'Hydrodynamics and Heat Transfer of Rheologically Complex Fluids in a Sulzer SMX Static Mixer,' Chem. Eng. Sci., Vol. 51, No. 10, pp. 1947-1955 https://doi.org/10.1016/0009-2509(96)00052-8
  8. Myers, K. J., Bakker, A. and Ryan, D., 1997, 'Avoid Agitation by Selecting Static Mixers,' Chem. Eng. Prog., Vol. 93, No. 6, pp. 28-38
  9. Pahl, M. H. and Muschelknautz, E., 1982, 'Static Mixers and Their Application,' Int. Chem. Eng., Vol. 22, No. 2, pp. 197-205
  10. Rauline, D, Tanguy, P. A., Belvec, J. L. and Bousquet, J., 1998, 'Numerical Investigation of the Performance of Several Static Mixers,' The Canadian J. of Chem. Eng., Vol. 76, pp. 527-535 https://doi.org/10.1002/cjce.5450760325
  11. Shah, N. F. and Kale, D. D., 1991, 'Pressure Drop for Laminar Flow of Non-Newtonian Fluids in Static Mixers,' Chem. Eng. Sci., Vol. 46, pp. 2159-2161 https://doi.org/10.1016/0009-2509(91)80175-X
  12. Sir, J. and Lecjaks, Z., 1982, 'Pressure Drop and Homogenization Efficiency of a Motionless Mixer,' Chem. Eng. Commun., Vol. 16, pp. 325-334 https://doi.org/10.1080/00986448208911104