낙동강 하류 갈전지역에서의 강변여과수 수질평가

Evaluation of Bank Filtrate Water Quality in Galjon, the Downstream of the Nakdong River

  • 이수영 (서울대학교 지구환경시스템공학부) ;
  • 정태학 (서울대학교 지구환경시스템공학부)
  • 투고 : 2002.06.21
  • 심사 : 2003.06.16
  • 발행 : 2003.08.15

초록

In this research, water qualities of river water and bank-filtrate were compared for six months including winter season. The location studied was Galjon area, the downstream of the Nakdong river. The well for bank-filtrate was installed 40 m apart from riverside. Main analytic results of bank-filtrate and river water were summarized as followings; the average concentrations in bank-filtrate were turbidity 0.8NTU, TN 0.4mg/l, $BOD_5$, 0.1mg/l, $KMnO_4$ consumption 1.6mg/l, heterotrophic bacteria 350cfu/ml, Fe 0.5mg/l, Mn 0.99mg/l while the average concentrations in river water were turbidity 6.1NTU, TN 3.9mg/l, $BOD_5$, 3.6mg/l, $KMnO_4$ consumption 11mg/l, heterotrophic bacteria 1,640cfu/ml, Fe 0.28mg/l, Mn 0.04mg/l. Water quality of bank-filtrate was mostly shown a good results than it of river water excepting Fe and Mn. In even basic constituents such as water temperature and pH, bank-filtrate was very settled while river water was extraordinary changable and high. In case of nitrogen, especially, total nitrogen of river water was 3.9mg/l while it of bank-filtrate was 0.4mg/l and its reduction was very high. The reason is that $NH^+_4-N$ among total nitrogen in the river water is nitrified and then denitrified in soil layer when it is pumped up as bank-filtrate. But Fe and Mn caused by the characteristics of soil was very high in bank-filtrate while Mn in river water was particularly very low and settled. As the distance between riverside and well was longer, concentration of Fe and Mn may be went up while its bacteria may be reduced.

키워드

참고문헌

  1. 송교욱, 박혜영, 박청길(1993) 낙동강 수계 수질관리를 위한 모델링(I)- 영양염류 분포특성에 관한 연구, 한국수질보전학회지, 9. pp.41-53
  2. 오정진, 이송희(1997) Fe Mn 제거를 위한 정수처리 기법, 수도. 24(2). pp.68-76
  3. 영남대(1999) 21세기 국제환경문제 상포지움. pp.12-32
  4. 허우명, 김범철 외(1995) 낙동강 수계의 인, 질소 및 Chl.a 농도분포, 학국육수학회, 28(2), pp.175-181
  5. 환경부(1997) 상수도시설기준, pp.300-363
  6. 환경부(1998) 전국 수도종합계획. pp. 343-367
  7. 환경부(1998) 이룡지구 강변여과수 시범개발 조사사업 실증실험보고서, 경상남도
  8. 환경부(1999) 지하수 수질기준 타당성 검토 및 조정방안 연구, pp. 18-31
  9. 환경부(2000) 환경백서 2000. pp.352-389
  10. 丹保憲仁, 松本孝子(昭38. 3) 過マンかン醒ヵリラムによる小道原水中のマンかン處理, 水道協會雜誌, 第342 pp.43-56
  11. AWWA, ASCE (1997) Water Treatment Plant Design, 3rd Ed. pp.283-320
  12. Degremount(1991) WaterTreatment Handbook, 6th Ed
  13. Sommerfeld, E.O. (1999) Iron and Manganese Removal Handbook, pp.1-158
  14. William R. Knocke, et al. (1994) Examining the reactions betweensoluble iron, DOC, and alternative oxidants during conventional treatrnent, JournaI AWWA, pp.177-127